CoChat

Association of Outcome with Left Ventricular Parameters Measured by Two-Dimensional and Three-Dimensional Echocardiography in Patients at High Cardiovascular Risk

Open access
Stanton, Tony, Jenkins, Carly, Haluska, Brian A., Marwick, Thomas H. · 2014 · Journal of the American Society of Echocardiography
Cited by 39

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND Left ventricular (LV) ejection fraction (EF) measured by two-dimensional echocardiographic (2DE) imaging is an important correlate of survival. Real-time three-dimensional echocardiographic (3DE) imaging has addressed some of the limitations of 2DE imaging. The aim of this study was to determine whether 3DE imaging is more predictive of outcomes than 2DE imaging. METHODS A total of 529 patients undergoing LV assessment with 2DE and 3DE imaging in 2003 and 2004 at a tertiary referral cardiac center were studied. Patients had a high frequency of cardiovascular risk factors. Images were gathered over four cardiac cycles using a matrix-array transducer, with measurements performed offline. Follow-up (all-cause mortality or cardiac hospitalization) was obtained over 6.6 ± 3.4 years in 455 of 486 patients with images suitable for measurement (94%). RESULTS There were 194 events (43%), including 75 deaths (16.4%). Larger LV volumes and lower EF were associated with worse outcomes independent of age, heart failure, or end-stage renal disease. In stepwise Cox regression analyses, the associations of cardiac hospitalization and survival with clinical variables (age, chronic kidney disease, and heart failure) were augmented by 3DE EF and end-systolic volume more than by 2DE parameters. The incremental model χ(2) value with 3DE EF was 14.67 (P < .001), compared with 9.72 (P = .002) for 2DE EF. Similarly, in Cox regression analyses of mortality, the effects of clinical variables (age, advanced renal disease, and heart failure) were augmented more by 3DE EF (incremental χ(2) = 14.04, P < .0001) than 2DE EF (incremental χ(2) = 5.13, P = .024). CONCLUSIONS In this outcome study, 3DE EF and volumes showed stronger associations with outcomes than those derived from 2DE imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.echo.2013.09.012

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 39

Metadata

Authors
Stanton, T., Jenkins, C., Haluska, B. A., & Marwick, T. H.
Venue
Journal of the American Society of Echocardiography
Publisher
Elsevier BV
Published
2014-01
Volume
27
Issue
1
Pages
65-73
ISSN
0894-7317 (ISSN-L)
OpenAlex
W2112351768
Cited by
39
References
4
FWCI
1.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.