CoChat

Effect of diabetes technologies on the fear of hypoglycaemia among people living with type 1 diabetes: a systematic review and meta-analysis

Open access
Talbo, Meryem K., Katz, Alexandra, Hill, Lee, Peters, Tricia M., Yale, Jean-François, Brazeau, Anne-Sophie · 2023 · eClinicalMedicine
Cited by 42

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Background Fear of hypoglycaemia (FOH) significantly disrupts the daily management of type 1 diabetes (T1D) and increases the risk of complications.Recent technological advances can improve glucose metrics and reduce hypoglycaemia frequency, yet their impact on FOH is unclear.This systematic review and meta-analysis (SRMA) aimed to synthesize the current literature to understand the impact of diabetes technologies on FOH in T1D.Methods In this SRMA, we searched PubMed, Medline, Scopus, and Web of Science from inception up to May 21st, 2023 for studies assessing the effect of using real-time or intermittently scanned continuous glucose monitors (rtCGM or isCGM); insulin pumps (CSII); and their combinations on FOH as the primary outcome, measured using the Hypoglycaemia Fear Survey (HFS; including total, worries [HFS-W], and behaviours [HFS-B] scores), in non-pregnant adults with T1D.Data was extracted by the first and second authors.Results were pooled using a random-effects model based on study design (RCT and non-RCT), with subgroup analysis based on the type of technology, reported change in hypoglycaemia frequency, and duration of use.Risk of bias was evaluated with Cochrane and Joanna Briggs Institute tools.This study is registered with PROSPERO, CRD42021253618.Findings A total of 51 studies (n = 8966) were included, 22 of which were RCTs.Studies on rtCGM and CSII reported lower FOH levels with ≥8 weeks of use.Studies on CSII and rtCGM combinations reported lower FOH levels after ≥13 weeks of automated insulin delivery (AID) use or 26 weeks of sensor-augmented pump (SAP) use.The metaanalysis showed an overall lower FOH with technologies, specifically for the HFS-W subscale.The RCT metaanalysis showed lower HFS-W scores with rtCGM use (standard mean difference [95%CI]: -0.14 [-0.23, -0.05],I 2 = 0%) and AID (-0.17 [-0.33, -0.01],I 2 = 0%).Results from non-RCT studies show that SAP users (-0.33 [-0.38, -0.27],I 2 = 0%) and rtCGM users (-0.38 [-0.61, -0.14],I 2 = 0%) had lower HFS-W.Interpretation We found consistent, yet small to moderate, effects supporting that diabetes technologies (specifically rtCGM, SAP, and AID) may reduce hypoglycaemia-related worries in adults with T1D.Current literature, however, has limitations including discrepancies in baseline characteristics and limited, mainly descriptive, statistical analysis.Thus, future studies should assess FOH as a primary outcome, use validated surveys, and appropriate statistical analysis to evaluate the clinical impacts of technology use beyond just glucose metrics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eclinm.2023.102119

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 42

Metadata

Authors
Talbo, M. K., Katz, A., Hill, L., Peters, T. M., Yale, J.-F., & Brazeau, A.-S.
Venue
eClinicalMedicine
Publisher
Elsevier BV
Published
2023-08
Volume
62
Pages
102119
ISSN
2589-5370 (ISSN-L)
OpenAlex
W4385580878
Cited by
42
References
28
FWCI
2.45
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of diabetes technologies on the fear of hypoglycaemia among people living with type 1 diabetes: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.eclinm.2023.102119
The paper
Talbo, M. K., Katz, A., Hill, L., Peters, T. M., Yale, J.-F., & Brazeau, A.-S. (2023). Effect of diabetes technologies on the fear of hypoglycaemia among people living with type 1 diabetes: a systematic review and meta-analysis. eClinicalMedicine. https://doi.org/10.1016/j.eclinm.2023.102119

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.