SEWGS Technology is Now Ready for Scale-up!
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In the FP7 project CAESAR, Air Products, BP, ECN, SINTEF and Politecnico di Milano worked together in the further development of the SEWGS process with the objective to reduce the energy penalty and the costs per ton of CO2 avoided to less than €25 through optimization of sorbent materials, reactor and process design and smart integration of the SEWGS unit in a combined cycle power plant. The most promising applications for the SEWGS technology are IGCC power plants and in combined cycles power plants fuelled with blast furnace top gas. Extensive sorbent development work resulted in a new sorbent called ALKASORB+ with a high capacity resulting in cost of CO2 avoided for the IGCC application of €23. This is a reduction of almost 40% compared to the Selexol capture case. Since ALKASORB+ requires much less steam in the regeneration, the specific primary energy consumption is reduced to 44% below the specific energy consumption for the Selexol (2.08 versus 3.71 MJLHV/kgCO2). From a technical point of view SEWGS is ready to move to the next development level, which is a pilot plant installation with a capacity of 35 ton CO2 per day. This is over 500 times larger than the current ECN's multi column SEWGS installation, but still 50 times smaller than an envisaged commercial scale installation. The pilot plant will prove the technology under field conditions and at a sufficiently large scale to enable further up-scaling, delivering both the basic design and investment costs of a full scale SEWGS demonstration plant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Walspurger, S., Cobden, P. D., Safonova, O. V., Wu, Y., & Anthony, E. J. (2010) · Chemistry – A European Journal · doi:10.1002/chem.201000687 · Cited by 58
Self-citation
Cited by
Carbon capture and storage (CCS): the way forward
Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., Fennell, P. S., Fuss, S., Galindo, A., Hackett, L. A., et al. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02342a · Cited by 4,374
Industrial carbon dioxide capture and utilization: state of the art and future challenges
Gao, W., Liang, S., Wang, R., Jiang, Q., Zhang, Y., Zheng, Q., Xie, B., Toe, C. Y., Zhu, X., Wang, J., et al. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00025f · Cited by 1,388
Hydrogen production with CO2 capture
Voldsund, M., Jordal, K., & Anantharaman, R. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.01.009 · Cited by 493
Jansen, D., Gazzani, M., Manzolini, G., Dijk, E. V., & Carbo, M. (2015) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2015.05.028 · Cited by 430
Self-citationRiboldi, L., & Bolland, O. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.03.1385 · Cited by 256
Metadata
- Authors
- Jansen, D., van Selow, E., Cobden, P., Manzolini, G., Macchi, E., Gazzani, M., Blom, R., Henriksen, P. P., Beavis, R., & Wright, A.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 37
- Pages
- 2265-2273
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W2029201844
- Cited by
- 56
- References
- 1
- FWCI
- 15.15
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SEWGS Technology is Now Ready for Scale-up! https://app.cochat.ai/papers/10.1016/j.egypro.2013.06.107
- The paper
- Jansen, D., van Selow, E., Cobden, P., Manzolini, G., Macchi, E., Gazzani, M., Blom, R., Henriksen, P. P., Beavis, R., & Wright, A. (2013). SEWGS Technology is Now Ready for Scale-up! Energy Procedia. https://doi.org/10.1016/j.egypro.2013.06.107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.