Outdoor Prototype Results for Direct Atmospheric Capture of Carbon Dioxide
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
At Carbon Engineering, we have built a prototype air contactor with 10 m 3 of packing volume, and have absorbed carbon dioxide from ambient air for over 1000 hours of outdoor operation. Our prototype was built to: a) test our cross-flow, pulsed-liquid, PVC packing-based contactor design in an operational environment; b) to evaluate fan and liquid pumping energy requirements of our design; c) to assess technical and safety risks involved with liquid solution loss through entrained “drift” droplets, and; d) to examine for packing or solution fouling by atmospheric particulates. In this paper we present our results on the liquid pumping and fan energy requirements of our prototype, and show preliminary analyses we have conducted on liquid loss through “drift” droplets and NPE fouling. Our operation with pulsed liquid flow allows us to fully wet the surface of our structured packing with a brief period of full flow, then to cut flow for a duration of several minutes to let the liquid slowly react away as CO 2 is absorbed. Using this technique we have cut average liquid flow to 10% of full manufacturer's specifications while retaining an average of over 80% of the capture rate observed at full flow. This method, under patent application, has allowed us to reduce our mgh fluid pumping energy requirement for the contactor to <40 MJ/ton-CO 2 (<11 kWh/ton-CO 2 ). Here we report this energy requirement without accounting for pump efficiency, which we nominally assume to be ηpump=90%. Our prototype contactor has utilized high-performance XF12560 structured packing from Brentwood Industries (Reading, PA), manufactured from PVC rather than a stainless-steel. This choice has given us several advantages, chiefly that it costs far less on a per-surface-area basis, and that is provides a much lower pressure drop on a per- surface-area basis. We have previously shown data that suggests these plastic packings absorb CO 2 with equal performance to traditional stainless-steel designs once wetted properly [1] . The high-performance and low pressure drop characteristics of our XF12560 product have allowed us to achieve PV work requirements of <350 MJ/ton-CO 2 (<100 kWh/ton-CO 2 ). Again, this value does not reflect fan efficiency, which we commonly use as ηfan=55% in our analyses. This current value for PV work requirement is higher than we had previously reported, due to a specific cause of under-performance in our prototype which is discussed in this paper. Despite this, we are in fact very encouraged by the results of our first attempt at long-duration outdoor contacting, and we have numerous design improvements stemming from our prototype operation that will be included in the next iteration of our full-scale contactor design. Extensive air sampling was carried out during our contactor operation to measure the loss of liquid solution via “drift” droplets. During normal pulsed-flow contactor operation, 6 hour air samples taken from the contact outflow and measured for our K + ion tracer, showed OH concentrations to be <5% of the OHSA regulated indoor respiratory requirement. After our 1000 hours of integrated CO 2 absorption time, we have as of yet been unable to observe any significant performance decrease in the absorptive properties of our working solution or in the efficiency of our structured packing product.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An air–liquid contactor for large-scale capture of CO2 from air
Holmes, G., & Keith, D. W. (2012) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2012.0137 · Cited by 197 · cited 4×
“This effective mass transfer coefficient (in units of mm/s), is our standard metric for indicating CO2 capture performance [2].”
BackgroundMethodSelf-citation
Cited by
Direct Capture of CO2 from Ambient Air
Sanz-Pérez, E. S., Murdock, C. R., Didas, S. A., & Jones, C. W. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00173 · Cited by 2,406
A Process for Capturing CO2 from the Atmosphere
Keith, D. W., Holmes, G., St. Angelo, D., & Heidel, K. (2018) · Joule · doi:10.1016/j.joule.2018.05.006 · Cited by 1,910
Self-citationNegative emissions—Part 2: Costs, potentials and side effects
Fuss, S., Lamb, W. F., Callaghan, M. W., Hilaire, J., Creutzig, F., Amann, T., Beringer, T., de Oliveira Garcia, W., Hartmann, J., Khanna, T., et al. (2018) · Environmental Research Letters · doi:10.1088/1748-9326/aabf9f · Cited by 1,525
“Holmes et al (2013) presented then a prototype with>1000 hours of operation, validating the cross-flow contactor design.”
MethodTechno-economic assessment of CO2 direct air capture plants
Fasihi, M., Efimova, O., & Breyer, C. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.03.086 · Cited by 1,171
A comparative energy and costs assessment and optimization for direct air capture technologies
Sabatino, F., Grimm, A., Gallucci, F., van Sint Annaland, M., Kramer, G. J., & Gazzani, M. (2021) · Joule · doi:10.1016/j.joule.2021.05.023 · Cited by 429
Metadata
- Authors
- Holmes, G., Nold, K., Walsh, T., Heidel, K., Henderson, M. A., Ritchie, J., Klavins, P., Singh, A., & Keith, D. W.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 37
- Pages
- 6079-6095
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W1966723149
- Cited by
- 73
- References
- 1
- FWCI
- 8.42
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outdoor Prototype Results for Direct Atmospheric Capture of Carbon Dioxide. https://app.cochat.ai/papers/10.1016/j.egypro.2013.06.537
- The paper
- Holmes, G., Nold, K., Walsh, T., Heidel, K., Henderson, M. A., Ritchie, J., Klavins, P., Singh, A., & Keith, D. W. (2013). Outdoor Prototype Results for Direct Atmospheric Capture of Carbon Dioxide. Energy Procedia. https://doi.org/10.1016/j.egypro.2013.06.537
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.