CoChat

Outdoor Prototype Results for Direct Atmospheric Capture of Carbon Dioxide

Open access
Holmes, Geoffrey, Nold, Kevin, Walsh, Tylor, Heidel, Kenton, Henderson, Matthew A., Ritchie, Jane, Klavins, Paul, Singh, Arvinder, Keith, David W. · 2013 · Energy Procedia
Cited by 73

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

At Carbon Engineering, we have built a prototype air contactor with 10 m 3 of packing volume, and have absorbed carbon dioxide from ambient air for over 1000 hours of outdoor operation. Our prototype was built to: a) test our cross-flow, pulsed-liquid, PVC packing-based contactor design in an operational environment; b) to evaluate fan and liquid pumping energy requirements of our design; c) to assess technical and safety risks involved with liquid solution loss through entrained “drift” droplets, and; d) to examine for packing or solution fouling by atmospheric particulates. In this paper we present our results on the liquid pumping and fan energy requirements of our prototype, and show preliminary analyses we have conducted on liquid loss through “drift” droplets and NPE fouling. Our operation with pulsed liquid flow allows us to fully wet the surface of our structured packing with a brief period of full flow, then to cut flow for a duration of several minutes to let the liquid slowly react away as CO 2 is absorbed. Using this technique we have cut average liquid flow to 10% of full manufacturer's specifications while retaining an average of over 80% of the capture rate observed at full flow. This method, under patent application, has allowed us to reduce our mgh fluid pumping energy requirement for the contactor to <40 MJ/ton-CO 2 (<11 kWh/ton-CO 2 ). Here we report this energy requirement without accounting for pump efficiency, which we nominally assume to be ηpump=90%. Our prototype contactor has utilized high-performance XF12560 structured packing from Brentwood Industries (Reading, PA), manufactured from PVC rather than a stainless-steel. This choice has given us several advantages, chiefly that it costs far less on a per-surface-area basis, and that is provides a much lower pressure drop on a per- surface-area basis. We have previously shown data that suggests these plastic packings absorb CO 2 with equal performance to traditional stainless-steel designs once wetted properly [1] . The high-performance and low pressure drop characteristics of our XF12560 product have allowed us to achieve PV work requirements of <350 MJ/ton-CO 2 (<100 kWh/ton-CO 2 ). Again, this value does not reflect fan efficiency, which we commonly use as ηfan=55% in our analyses. This current value for PV work requirement is higher than we had previously reported, due to a specific cause of under-performance in our prototype which is discussed in this paper. Despite this, we are in fact very encouraged by the results of our first attempt at long-duration outdoor contacting, and we have numerous design improvements stemming from our prototype operation that will be included in the next iteration of our full-scale contactor design. Extensive air sampling was carried out during our contactor operation to measure the loss of liquid solution via “drift” droplets. During normal pulsed-flow contactor operation, 6 hour air samples taken from the contact outflow and measured for our K + ion tracer, showed OH concentrations to be <5% of the OHSA regulated indoor respiratory requirement. After our 1000 hours of integrated CO 2 absorption time, we have as of yet been unable to observe any significant performance decrease in the absorptive properties of our working solution or in the efficiency of our structured packing product.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.egypro.2013.06.537

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Holmes, G., Nold, K., Walsh, T., Heidel, K., Henderson, M. A., Ritchie, J., Klavins, P., Singh, A., & Keith, D. W.
Venue
Energy Procedia
Publisher
Elsevier BV
Published
2013
Volume
37
Pages
6079-6095
ISSN
1876-6102 (ISSN-L)
OpenAlex
W1966723149
Cited by
73
References
1
FWCI
8.42
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.