The transformation of radiation oncology using real-time magnetic resonance guidance: A review
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Radiation therapy (RT) is an essential component of effective cancer care and is used across nearly all cancer types. The delivery of RT is becoming more precise through rapid advances in both computing and imaging. The direct integration of magnetic resonance imag-ing (MRI) with linear accelerators represents an exciting development with the potential todramatically impact cancer research and treatment. These impacts extend beyond improved imaging and dose deposition. Real-time MRI-guided RT is actively transforming the work flows and capabilities of virtually every aspect of RT. It has the opportunity to change entirely the delivery methods and response assessments of numerous malignancies. This review intends to approach the topic of MRI-based RT guidance from a vendor neutral and international perspective. It also aims to provide an introduction to this topic targeted towards oncologists without a speciality focus in RT. Speciality implications, areas for physician education and research opportunities are identified as they are associated with MRI-guided RT. The uniquely disruptive implications of MRI-guided RT are discussed and placed in context. We further aim to describe and outline important future changes to the speciality of radiation oncology that will occur with MRI-guided RT. The impacts on RT caused by MRI guidance include target identification, RT planning, quality assurance, treatment delivery, training, clinical workflow, tumour response assessment and treatment scheduling. In addition, entirely novel research areas that may be enabled by MRI guidance are identified for future investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bradley, J. D., Paulus, R., Komaki, R., Masters, G., Blumenschein, G., Schild, S., Bogart, J., Hu, C., Forster, K., Magliocco, A., et al. (2015) · The Lancet Oncology · doi:10.1016/s1470-2045(14)71207-0 · Cited by 2,015
Self-citationDiffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Nutting, C. M., Morden, J. P., Harrington, K. J., Urbano, T. G., Bhide, S. A., Clark, C., Miles, E. A., Miah, A. B., Newbold, K., Tanay, M., et al. (2011) · The Lancet Oncology · doi:10.1016/s1470-2045(10)70290-4 · Cited by 1,706
Self-citationExpanding global access to radiotherapy
Atun, R., Jaffray, D. A., Barton, M. B., Bray, F., Baumann, M., Vikram, B., Hanna, T. P., Knaul, F. M., Lievens, Y., Lui, T. Y. M., et al. (2015) · The Lancet Oncology · doi:10.1016/s1470-2045(15)00222-3 · Cited by 1,112
Self-citationImaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
The ViewRay System: Magnetic Resonance–Guided and Controlled Radiotherapy
Mutic, S., & Dempsey, J. F. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.008 · Cited by 915
Raaymakers, B. W., Jürgenliemk-Schulz, I. M., Bol, G. H., Glitzner, M., Kotte, A. N. T. J., van Asselen, B., de Boer, J. C. J., Bluemink, J. J., Hackett, S. L., Moerland, M. A., et al. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9517 · Cited by 541
Self-citationLagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511
Self-citationBortfeld, T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r21 · Cited by 505
Image-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496 · cited 2×
“Image-guided RT (IGRT) has represented an important advance in RT for well over a decade [2].”
BackgroundSelf-citationThe Magnetic Resonance Imaging–Linac System
Lagendijk, J. J. W., Raaymakers, B. W., & van Vulpen, M. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.009 · Cited by 464 · cited 20×
“The ViewRay MRI-cobalt device has been US Food and Drug Administration (FDA) approved since May 22, 2012, and Viewray MRIdian linear accelerator has been approved since February 24, 2017 and the Elekta Unity system received FDA approval on December 5th, 2018.”
MethodInfluentialSelf-citationRaaijmakers, A. J. E., Raaymakers, B. W., & Lagendijk, J. J. W. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/7/002 · Cited by 380
Self-citationThe Australian Magnetic Resonance Imaging–Linac Program
Keall, P. J., Barton, M., & Crozier, S. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.015 · Cited by 351
Rudra, S., Jiang, N., Rosenberg, S. A., Olsen, J. R., Roach, M. C., Wan, L., Portelance, L., Mellon, E. A., Bruynzeel, A., Lagerwaard, F., et al. (2019) · Cancer Medicine · doi:10.1002/cam4.2100 · Cited by 350
Self-citationDynamic contrast-enhanced MRI in clinical trials of antivascular therapies
O'Connor, J. P. B., Jackson, A., Parker, G. J. M., Roberts, C., & Jayson, G. C. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.2 · Cited by 348
Liao, Z., Lee, J. J., Komaki, R., Gomez, D. R., O’Reilly, M. S., Fossella, F. V., Blumenschein, G. R., Heymach, J. V., Vaporciyan, A. A., Swisher, S. G., et al. (2018) · Journal of Clinical Oncology · doi:10.1200/jco.2017.74.0720 · Cited by 336
Fallone, B. G., Murray, B., Rathee, S., Stanescu, T., Steciw, S., Vidakovic, S., Blosser, E., & Tymofichuk, D. (2009) · Medical Physics · doi:10.1118/1.3125662 · Cited by 325
Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications
Acharya, S., Fischer-Valuck, B. W., Kashani, R., Parikh, P., Yang, D., Zhao, T., Green, O., Wooten, O., Li, H. H., Hu, Y., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.10.015 · Cited by 302
Self-citationSun, Y.-S., Zhang, X.-P., Tang, L., Ji, J.-F., Gu, J., Cai, Y., & Zhang, X.-Y. (2010) · Radiology · doi:10.1148/radiol.2541082230 · Cited by 292
Hamstra, D. A., Galbán, C. J., Meyer, C. R., Johnson, T. D., Sundgren, P. C., Tsien, C., Lawrence, T. S., Junck, L., Ross, D. J., Rehemtulla, A., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.15.2363 · Cited by 281
An overview of CEST MRI for non-MR physicists
Wu, B., Warnock, G., Zaiss, M., Lin, C., Chen, M., Zhou, Z., Mu, L., Nanz, D., Tuura, R., & Delso, G. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0155-2 · Cited by 274
The Rotating Biplanar Linac–Magnetic Resonance Imaging System
Fallone, B. G. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.011 · Cited by 260
Sio, T. T., Lin, H.-K., Shi, Q., Gunn, G. B., Cleeland, C. S., Lee, J. J., Hernandez, M., Blanchard, P., Thaker, N. G., Phan, J., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.02.044 · Cited by 166
Self-citationBoldrini, L., Cusumano, D., Chiloiro, G., Casà, C., Masciocchi, C., Lenkowicz, J., Cellini, F., Dinapoli, N., Azario, L., Teodoli, S., et al. (2019) · La radiologia medica · doi:10.1007/s11547-018-0951-y · Cited by 147
Kerkmeijer, L. G. W., Fuller, C. D., Verkooijen, H. M., Verheij, M., Choudhury, A., Harrington, K. J., Schultz, C., Sahgal, A., Frank, S. J., Goldwein, J. L., et al. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00215 · Cited by 138
Self-citationIntravoxel incoherent motion MRI as a means to measure in vivo perfusion: A review of the evidence
Federau, C. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3780 · Cited by 117
Feasibility of MRI guided proton therapy: magnetic field dose effects
Raaymakers, B. W., Raaijmakers, A. J. E., & Lagendijk, J. J. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/20/003 · Cited by 113
Self-citationYang, Y., Cao, M., Sheng, K., Gao, Y., Chen, A. R., Kamrava, M., Lee, P. P., Agazaryan, N., Lamb, J., Thomas, D. H., et al. (2016) · Medical Physics · doi:10.1118/1.4942381 · Cited by 112
Self-citationEl-Bared, N., Portelance, L., Spieler, B. O., Kwon, D., Padgett, K. R., Brown, K., & Mellon, E. A. (2018) · Practical Radiation Oncology · doi:10.1016/j.prro.2018.08.010 · Cited by 95
Palacios, M. A., Bohoudi, O., Bruynzeel, A. M. E., de Koste, J. R. V. S., Cobussen, P., Slotman, B. J., Lagerwaard, F. J., & Senan, S. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.06.002 · Cited by 91
Evaluation of Glioblastoma Response to Therapy With Chemical Exchange Saturation Transfer
Mehrabian, H., Myrehaug, S. D., Soliman, H., Sahgal, A., & Stanisz, G. J. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.03.057 · Cited by 82
Self-citationChange in diffusion weighted MRI during liver cancer radiotherapy: Preliminary observations
Eccles, C. L., Haider, E. A., Haider, M. A., Fung, S., Lockwood, G., & Dawson, L. A. (2009) · Acta Oncologica · doi:10.1080/02841860903099972 · Cited by 78
Self-citationHo, J., Allen, P. K., Bhosale, P., Rauch, G. M., Fuller, C. D., Mohamed, A., Frumovitz, M., Jhingran, A., & Klopp, A. H. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.11.015 · Cited by 73
Self-citationPaudyal, R., Oh, J. H., Riaz, N., Venigalla, P., Li, J., Hatzoglou, V., Leeman, J. E., Núñez, D. A., Lu, Y., Deasy, J. O., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25523 · Cited by 64
Quantitative rotating frame relaxometry methods in MRI
Gilani, I., & SEPPONEN, R. E. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3518 · Cited by 63
Tyran, M., Jiang, N. Y., Cao, M., Raldow, A. C., Lamb, J. M., Low, D. A., Luterstein, E., Steinberg, M. L., & Lee, P. P. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.08.009 · Cited by 56
Self-citationPark, J. M., Shin, K. H., Kim, J.-I., Park, S. Y., Jeon, S. H., Choi, N., Kim, J. H., & Wu, H.-G. (2017) · Strahlentherapie und Onkologie · doi:10.1007/s00066-017-1212-z · Cited by 55
Correlation of ADC With Pathological Treatment Response for Radiation Therapy of Pancreatic Cancer
Dalah, E. Z., Erickson, B. A., Oshima, K., Schött, D., Hall, W. A., Paulson, E. S., Tai, A., Knechtges, P., & Li, X. A. (2018) · Translational Oncology · doi:10.1016/j.tranon.2018.01.018 · Cited by 54
Self-citationZhu, L., Zhu, L., Shi, H., Wang, H., Yan, J., Liu, B., Chen, W., He, J., Zhou, Z., Yang, X., et al. (2016) · BMC Cancer · doi:10.1186/s12885-016-2116-5 · Cited by 54
Shaverdian, N., Yang, Y., Hu, P., Hart, S., Sheng, K., Lamb, J., Cao, M., Agazaryan, N., Thomas, D. H., Steinberg, M. L., et al. (2017) · British Journal of Radiology · doi:10.1259/bjr.20160739 · Cited by 53
Self-citationGaeta, M., Benedetto, C., Minutoli, F., D’Angelo, T., Amato, E., Mazziotti, S., Racchiusa, S., Mormina, E., Blandino, A., & Pergolizzi, S. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.05.021 · Cited by 50
Tetar, S., Bruynzeel, A. M. E., Bakker, R., Jeulink, M., Slotman, B. J., Oei, S. S., Haasbeek, C. J. A., Jong, K. D., Senan, S., & Lagerwaard, F. J. (2018) · Cureus · doi:10.7759/cureus.2236 · Cited by 48
Quantitative Magnetization Transfer in Monitoring Glioblastoma (GBM) Response to Therapy
Mehrabian, H., Myrehaug, S. D., Soliman, H., Sahgal, A., & Stanisz, G. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-20624-6 · Cited by 44
Self-citationZhu, L., Wang, H., Zhu, L., Meng, J., Yan, X., Liu, B., Chen, W., He, J., Zhou, Z., & Yang, X. (2017) · Scientific Reports · doi:10.1038/s41598-017-11988-2 · Cited by 37
Glioblastoma (GBM) effects on quantitative MRI of contralateral normal appearing white matter
Mehrabian, H., Lam, W. W., Myrehaug, S. D., Sahgal, A., & Stanisz, G. J. (2018) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-2846-0 · Cited by 24
Self-citationBisdas, S., Smrdel, U., Bajrović, F. F., & Surlan-Popović, K. (2014) · Clinical Neuroradiology · doi:10.1007/s00062-014-0328-0 · Cited by 21
Li, F. P., Wang, H., Hou, J., Tang, J., Lu, Q., Wang, L., & Yu, X. (2018) · Clinical Radiology · doi:10.1016/j.crad.2018.03.015 · Cited by 13
Bonekamp, D., Wolf, M. B., Edler, C., Katayama, S., Schlemmer, H.-P., Herfarth, K. K., & Röthke, M. C. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.05.012 · Cited by 12
You, D., Aryal, M. P., Samuels, S. E., Eisbruch, A., & Cao, Y. (2016) · Tomography · doi:10.18383/j.tom.2016.00199 · Cited by 11
Emmerich, J., Laun, F. B., Pfaffenberger, A., Schilling, R., Denoix, M., Maier, F. C., Sterzing, F., Bostel, T., & Straub, S. (2018) · Medical Physics · doi:10.1002/mp.12785 · Cited by 10
Cited by
Deep learning based synthetic‐CT generation in radiotherapy and PET: A review
Spadea, M. F., Maspero, M., Zaffino, P., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.15150 · Cited by 201
Metadata
- Authors
- Hall, W. A., Paulson, E. S., van der Heide, U. A., Fuller, C. D., Raaymakers, B. W., Lagendijk, J. J. W., Li, X. A., Jaffray, D. A., Dawson, L. A., Erickson, B., Verheij, M., Harrington, K. J., Sahgal, A., Lee, P., Parikh, P. J., Bassetti, M. F., Robinson, C. G., Minsky, B. D., Choudhury, A., Tersteeg, R. J. H. A., & Schultz, C. J.
- Venue
- European Journal of Cancer
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 122
- Pages
- 42-52
- ISSN
- 0959-8049 (ISSN-L)
- OpenAlex
- W2975664877
- Cited by
- 184
- References
- 50
- FWCI
- 20.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.