Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND Atrial High Rate Episodes (AHRE) are asymptomatic atrial tachy-arrhythmias detected through continuous monitoring with a cardiac implantable electronic device. The risks of stroke/Thromboembolic (TE) events and incident clinical Atrial Fibrillation (AF) associated with AHRE varies markedly. OBJECTIVES To assess the relationship between AHRE and TE events, and between AHRE and incident clinical AF. METHODS This systematic review and meta-analysis was conducted following the PRISMA recommendations. PubMed, Scopus, and Google Scholar were searched from inception to 18/02/2021 for studies reporting TE events and incident clinical AF in patients with AHRE, as compared with patients without. RESULTS Ten out of 8081 records fulfilled the inclusion criteria, for a total of 37 266 patients. Seven out of ten studies excluded patients with prior history of clinical AF (4961 patients), embracing the most recent definition of AHRE. The risk ratio (RR) for TE events in AHRE patients was 2.13 (95% CI: 1.53-2.95, I2: 0%). The incidence of clinical AF was reported in four studies excluding patients with a history of clinical AF (3574 patients). The RR for incident clinical AF was 3.34 (95%CI: 1.89-5.90, I2: 73%). CONCLUSIONS AHRE are significantly associated with systemic thromboembolism and incident clinical AF. Further studies are needed to improve patients' risk stratification and management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RoB 2: a revised tool for assessing risk of bias in randomised trials
Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., et al. (2019) · BMJ · doi:10.1136/bmj.l4898 · Cited by 34,787
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Boriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Self-citationBOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Self-citation
Cited by
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationMartin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Martin, S. S., Aday, A. W., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Beaton, A. Z., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001303 · Cited by 1,080
Metadata
- Authors
- Vitolo, M., Imberti, J. F., Maisano, A., Albini, A., Bonini, N., Valenti, A. C., Malavasi, V. L., Proietti, M., Healey, J. S., Lip, G. Y., & Boriani, G.
- Venue
- European Journal of Internal Medicine
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 92
- Pages
- 100-106
- ISSN
- 0953-6205 (ISSN-L)
- OpenAlex
- W3173908856
- Cited by
- 66
- References
- 6
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.ejim.2021.05.038
- The paper
- Vitolo, M., Imberti, J. F., Maisano, A., Albini, A., Bonini, N., Valenti, A. C., Malavasi, V. L., Proietti, M., Healey, J. S., Lip, G. Y., & Boriani, G. (2021). Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis. European Journal of Internal Medicine. https://doi.org/10.1016/j.ejim.2021.05.038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.