Abstract
PURPOSE The analysis of PET images by textural features, also known as radiomics, shows promising results in tumor characterization. However, radiomic metrics (RMs) analysis is currently not standardized and the impact of the whole processing chain still needs deep investigation. We characterized the impact on RM values of: i) two discretization methods, ii) acquisition statistics, and iii) reconstruction algorithm. The influence of tumor volume and standardized-uptake-value (SUV) on RM was also investigated. METHODS The Chang-Gung-Image-Texture-Analysis (CGITA) software was used to calculate 39 RMs using phantom data. Thirty noise realizations were acquired to measure statistical effect size indicators for each RM. The parameter η2 (fraction of variance explained by the nuisance factor) was used to assess the effect of categorical variables, considering η2 < 20% and 20% < η2 < 40% as representative of a "negligible" and a "small" dependence respectively. The Cohen's d was used as discriminatory power to quantify the separation of two distributions. RESULTS We found the discretization method based on fixed-bin-number (FBN) to outperform the one based on fixed-bin-size in units of SUV (FBS), as the latter shows a higher SUV dependence, with 30 RMs showing η2 > 20%. FBN was also less influenced by the acquisition and reconstruction setup:with FBN 37 RMs had η2 < 40%, only 20 with FBS. Most RMs showed a good discriminatory power among heterogeneous PET signals (for FBN: 29 out of 39 RMs with d > 3). CONCLUSIONS For RMs analysis, FBN should be preferred. A group of 21 RMs was suggested for PET radiomics analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eta-squared and partial eta-squared in fixed factor anova designs
Cohen, J. (1973) · Educational and Psychological Measurement · doi:10.1177/001316447303300111 · Cited by 1,333
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Repeatability and reproducibility of MRI-based radiomic features in cervical cancer
Fiset, S., Welch, M. L., Weiss, J., Pintilie, M., Conway, J. L., Milosevic, M., Fyles, A., Traverso, A., Jaffray, D., Metser, U., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.001 · Cited by 167
Reynés-Llompart, G., Sabaté-Llobera, A., Llinares-Tello, E., Martí-Climent, J. M., & Gámez-Cenzano, C. (2019) · Scientific Reports · doi:10.1038/s41598-019-46937-8 · Cited by 35
Metadata
- Authors
- Presotto, L., Bettinardi, V., De Bernardi, E., Belli, M. L., Cattaneo, G. M., Broggi, S., & Fiorino, C.
- Venue
- Physica Medica
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 50
- Pages
- 66-74
- ISSN
- 1120-1797 (ISSN-L)
- OpenAlex
- W2807211466
- Cited by
- 41
- References
- 1
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.