The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Repeatability and reproducibility of MRI-based radiomic features in cervical cancer
Abstract
PURPOSE The aims of this study are to evaluate the stability of radiomic features from T2-weighted MRI of cervical cancer in three ways: (1) repeatability via test-retest; (2) reproducibility between diagnostic MRI and simulation MRI; (3) reproducibility in inter-observer setting. MATERIALS AND METHODS This retrospective cohort study included FIGO stage IB-IVA cervical cancer patients treated with chemoradiation between 2005 and 2014. There were three cohorts of women corresponding to each aim of the study: (1) 8 women who underwent test-retest MRI; (2) 20 women who underwent MRI on different scanners (diagnostic and simulation MRI); (3) 34 women whose diagnostic MRIs were contoured by three observers. Radiomic features based on first-order statistics, shape features and texture features were extracted from the original, Laplacian of Gaussian (LoG)-filtered and wavelet-filtered images, for a total of 1761 features. Stability of radiomic features was assessed using intraclass correlation coefficient (ICC). RESULTS The inter-observer cohort had the most reproducible features (95.2% with ICC ≥0.75) whereas the diagnostic-simulation cohort had the fewest (14.1% with ICC ≥0.75). Overall, 229 features had ICC ≥0.75 in all three tests. Shape features emerged as the most stable features in all cohorts. CONCLUSION The diagnostic-simulation test resulted in the fewest reproducible features. Further research in MRI-based radiomics is required to validate the use of reproducible features in prognostic models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Answering the Call for a Standard Reliability Measure for Coding Data
Hayes, A. F., & Krippendorff, K. (2007) · Communication Methods and Measures · doi:10.1080/19312450709336664 · Cited by 4,225
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
A review in radiomics: Making personalized medicine a reality via routine imaging
Guiot, J., Vaidyanathan, A., Deprez, L., Zerka, F., Danthine, D., Frix, A., Lambin, P., Bottari, F., Tsoutzidis, N., Miraglio, B., et al. (2022) · Medicinal Research Reviews · doi:10.1002/med.21846 · Cited by 337
Radiogenomics: bridging imaging and genomics
Bodalal, Z., Trebeschi, S., Nguyen-Kim, T. D. L., Schats, W., & Beets-Tan, R. (2019) · Abdominal Radiology · doi:10.1007/s00261-019-02028-w · Cited by 310
Ibrahim, A., Primakov, S., Beuque, M., Woodruff, H. C., Halilaj, I., Wu, G., Refaee, T., Granzier, R., Widaatalla, Y., Hustinx, R., et al. (2021) · Methods · doi:10.1016/j.ymeth.2020.05.022 · Cited by 265
Moradmand, H., Aghamiri, S. M. R., & Ghaderi, R. (2020) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12795 · Cited by 173
Metadata
- Authors
- Fiset, S., Welch, M. L., Weiss, J., Pintilie, M., Conway, J. L., Milosevic, M., Fyles, A., Traverso, A., Jaffray, D., Metser, U., Xie, J., & Han, K.
- Venue
- Radiotherapy and Oncology
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 135
- Pages
- 107-114
- ISSN
- 0167-8140 (ISSN-L)
- OpenAlex
- W2923943486
- Cited by
- 167
- References
- 4
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Repeatability and reproducibility of MRI-based radiomic features in cervical cancer. https://app.cochat.ai/papers/10.1016/j.radonc.2019.03.001
- The paper
- Fiset, S., Welch, M. L., Weiss, J., Pintilie, M., Conway, J. L., Milosevic, M., Fyles, A., Traverso, A., Jaffray, D., Metser, U., Xie, J., & Han, K. (2019). Repeatability and reproducibility of MRI-based radiomic features in cervical cancer. Radiotherapy and Oncology. https://doi.org/10.1016/j.radonc.2019.03.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.