Diagnosis and management of complications following pelvic organ prolapse surgery using a synthetic mesh: French national guidelines for clinical practice

Deffieux, Xavier, Perrouin-Verbe, Marie-Aimée, Campagne-Loiseau, Sandrine, Donon, Laurence, Levesque, Amélie, Rigaud, Jérome, Stivalet, Nadja, Venara, Aurélien +6 more·2024·European Journal of Obstetrics & Gynecology and Reproductive Biology

Abstract

Complications associated with pelvic organ prolapse (POP) surgery using a synthetic non-absorbable mesh are uncommon (<5%) but may be severe and may hugely diminish the quality of life of some women. In drawing up these multidisciplinary clinical practice recommendations, the French National Authority for Health (Haute Autorité de santé, HAS) conducted an exhaustive review of the literature concerning the diagnosis, prevention, and management of complications associated with POP surgery using a synthetic mesh. Each recommendation for practice was allocated a grade (A,B or C; or expert opinion (EO)), which depends on the level of evidence (clinical practice guidelines).Preoperative patients' information Each patient must be informed concerning the risks associated with POP surgery (EO).Hemorrhage, hematoma Vaginal infiltration using a vasoconstrictive solution is not recommended during POP surgery by the vaginal route (grade C). The placement of vaginal packing is not recommended following POP surgery by the vaginal route (grade C). During laparoscopic sacral colpopexy, when the promontory seems highly dangerous or when severe adhesions prevent access to the anterior vertebral ligament, alternative surgical techniques should be discussed per operatively, including colpopexy by lateral mesh laparoscopic suspension, uterosacral ligament suspension, open abdominal mesh surgery, or surgery by the vaginal route (EO).Bladder injury When a bladder injury is diagnosed, bladder repair by suturing is recommended, using a slow resorption suture thread, plus monitoring of the permeability of the ureters (before and after bladder repair) when the injury is located at the level of the trigone (EO). When a bladder injury is diagnosed, after bladder repair, a prosthetic mesh (polypropylene or polyester material) can be placed between the repaired bladder and the vagina, if the quality of the suturing is good. The recommended duration of bladder catheterization following bladder repair in this context of POP mesh surgery is from 5 to 10 days (EO).Ureter injury After ureteral repair, it is possible to continue sacral colpopexy and place the mesh if it is located away from the ureteral repair (EO).Rectal injury Regardless of the approach, when a rectal injury occurs, a posterior mesh should not be placed between the rectum and the vagina wall (EO). Concerning the anterior mesh, it is recommended to use a macroporous monofilament polypropylene mesh (EO). A polyester mesh is not recommended in this situation (EO).Vaginal wall injury After vaginal wall repair, an anterior or a posterior microporous polypropylene mesh can be placed, if the quality of the repair is found to be satisfactory (EO). A polyester mesh should not be used after vaginal wall repair (EO).Mesh infection (abscess, cellulitis, spondylodiscitis) Regardless of the surgical approach, intravenous antibiotic prophylaxis is recommended (aminopenicillin + beta-lactamase inhibitor: 30 min before skin incision +/- repeated after 2 h if surgery lasts longer) (EO). When spondylodiscitis is diagnosed following sacral colpopexy, treatment should be discussed by a multidisciplinary group, including especially spine specialists (rheumatologists, orthopedists, neurosurgeons) and infectious disease specialists (EO). When a pelvic abscess occurs following synthetic mesh sacral colpopexy, it is recommended to carry out complete mesh removal as soon as possible, combined with collection of intraoperative bacteriological samples, drainage of the collection and targeted antibiotic therapy (EO). Non-surgical conservative management with antibiotic therapy may be an option (EO) in certain conditions (absence of signs of sepsis, macroporous monofilament polypropylene type 1 mesh, prior microbiological documentation and multidisciplinary consultation for the choice of type and duration of antibiotic therapy), associated with close monitoring of the patient.Bowel occlusion related to non-closure of the peritoneum Peritoneal closure is recommended after placement of a synthetic mesh by the abdominal approach (EO).Urinary retention Preoperative urodynamics is recommended in women presenting with urinary symptoms (bladder outlet obstruction symptoms, overactive bladder syndrome or incontinence) (EO). It is recommended to remove the bladder catheter at the end of the procedure or within 48 h after POP surgery (grade B). Bladder emptying and post-void residual should be checked following POP surgery, before discharge (EO). When postoperative urine retention occurs after POP surgery, it is recommended to carry out indwelling catheterization and to prefer intermittent self-catheterization (EO).Postoperative pain Before POP surgery, the patient should be asked about risk factors for prolonged and chronic postoperative pain (pain sensitization, allodynia, chronic pelvic or non-pelvic pain) (EO). Concerning the prevention of postoperative pain, it is recommended to carry out a pre-, per- and postoperative multimodal pain treatment (grade B). The use of ketamine intraoperatively is recommended for the prevention of chronic postoperative pelvic pain, especially for patients with risk factors (preoperative painful sensitization, allodynia, chronic pelvic or non-pelvic pain) (EO). Postoperative prescription of opioids should be limited in quantity and duration (grade C). When acute neuropathic pain (sciatalgia or pudendal neuralgia) resistant to level I and II analgesics occurs following sacrospinous fixation, a reintervention is recommended for suspension suture removal (EO). When chronic postoperative pain occurs after POP surgery, it is recommended to systematically seek arguments in favor of neuropathic pain with the DN4 questionnaire (EO). When chronic postoperative pelvic pain occurs after POP surgery, central sensitization should be identified since it requires a consultation in a chronic pain department (EO). Concerning myofascial pain syndrome (clinical pain condition associated with increased muscle tension caused by myofascial trigger points), when chronic postoperative pain occurs after POP surgery, it is recommended to examine the levator ani, piriformis and obturator internus muscles, so as to identify trigger points on the pathway of the synthetic mesh (EO). Pelvic floor muscle training with muscle relaxation is recommended when myofascial pain syndrome is associated with chronic postoperative pain following POP surgery (EO). After failure of pelvic floor muscle training (3 months), it is recommended to discuss surgical removal of the synthetic mesh, during a multidisciplinary discussion group meeting (EO). Partial removal of synthetic mesh is indicated when a trigger point is located on the pathway of the mesh (EO). Total removal of synthetic mesh should be discussed during a multidisciplinary discussion group meeting when diffuse (no trigger point) chronic postoperative pain occurs following POP surgery, with or without central sensitization or neuropathic pain syndromes (EO).Postoperative dyspareunia When de novo postoperative dyspareunia occurs after POP surgery, surgical removal of the mesh should be discussed (EO).Vaginal mesh exposure To reduce the risk of vaginal mesh exposure, when hysterectomy is required during sacral colpopexy, subtotal hysterectomy is recommended (grade C). When asymptomatic vaginal macroporous monofilament polypropylene mesh exposure occurs, systematic imaging is not recommended. When vaginal polyester mesh exposure occurs, pelvic +/- lumbar MRI (EO) should be used to look for an abscess or spondylodiscitis, given the greater risk of infection associated with this type of material. When asymptomatic vaginal mesh exposure of less than 1 cm2 occurs in a woman with no sexual intercourse, the patient should be offered observation (no treatment) or local estrogen therapy (EO). However, if the patient wishes, partial excision of the mesh can be offered. When asymptomatic vaginal mesh exposure of more than 1 cm2 occurs or if the woman has sexual intercourse, or if it is a polyester prosthesis, partial mesh excision, either immediately or after local estrogen therapy, should be offered (EO). When symptomatic vaginal mesh exposure occurs, but without infectious complications, surgical removal of the exposed part of the mesh by the vaginal route is recommended (EO), and not systematic complete excision of the mesh. Following sacral colpopexy, complete removal of the mesh (by laparoscopy or laparotomy) is only required in the presence of an abscess or spondylodiscitis (EO). When vaginal mesh exposure recurs after a first reoperation, the patient should be treated by an experienced team specialized in this type of complication (EO).Suture thread vaginal exposure For women presenting with vaginal exposure to non-absorbable suture thread following POP surgery with mesh reinforcement, the suture thread should be removed by the vaginal route (EO). Removal of the surrounding mesh is only recommended when vaginal mesh exposure or associated abscess is diagnosed.Bladder and ureteral mesh exposure When bladder mesh exposure occurs, removal of the exposed part of the mesh is recommended (grade B). Both alternatives (total or partial mesh removal) should be discussed with the patient and should be debated during a multidisciplinary discussion group meeting (EO).

Integrity signals

Registry

Crossref · 10.1016/j.ejogrb.2024.01.015

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Deffieux, X., Perrouin-Verbe, M.-A., Campagne-Loiseau, S., Donon, L., Levesque, A., Rigaud, J., Stivalet, N., Venara, A., Thubert, T., Vidart, A., Bosset, P.-O., Revel-Delhom, C., Lucot, J.-P., & Hermieu, J. F.
Affiliations
  • Université Paris-Saclay (FR)
  • Centre Hospitalier Universitaire de Clermont-Ferrand (FR)
  • Centre Hospitalier Universitaire de Nantes (FR)
  • Université Paris Cité (FR)
  • Centre Hospitalier Universitaire d'Angers (FR)
  • Hôpital Foch (FR)
  • Université Catholique de Lille (FR)
Corresponding author
Deffieux, Xavier
Venue
European Journal of Obstetrics & Gynecology and Reproductive Biology
Publisher
Elsevier BV
Published
2024-03
Volume
294
Pages
170-179
ISSN
  • 0028-2243 (ISSN-L)
  • 0301-2115
OpenAlex
W4390955396
Cited by
31
References
38
Citations by year
2026: 17 · 2025: 7 · 2024: 7
FWCI
2.30
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Obstetrics & Gynecology and Reproductive Biology (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Pelvic floor disorders treatments
  • Health Sciences › Medicine › Surgery › Hernia repair and management
  • Health Sciences › Medicine › Obstetrics and Gynecology › Uterine Myomas and Treatments
Keywords
pelvic organ prolapse, synthetic mesh, surgical complications, sacrocolpopexy, bladder injury, ureteral injury, rectal injury, mesh erosion, mesh migration, mesh exposure, mesh removal, pelvic floor reconstruction, postoperative care, patient information
MeSH terms
Abscess, Anti-Bacterial Agents, Urinary Bladder Diseases, Dyspareunia, Estrogens, Female, Humans, Hyperalgesia, Myofascial Pain Syndromes, Neuralgia, Postoperative Pain, Polyesters, Polypropylenes, Quality of Life, Surgical Mesh, Vagina, Discitis, Treatment Outcome, Pelvic Pain, Prostheses and Implants, Pelvic Organ Prolapse

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›