Chest tomosynthesis: Technical principles and clinical update
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Digital tomosynthesis is a radiographic technique that can produce an arbitrary number of section images of a patient from a single pass of the x-ray tube. It utilizes a conventional x-ray tube, a flat-panel detector, a computer-controlled tube mover, and special reconstruction algorithms to produce section images. While it does not have the depth resolution of computed tomography (CT), tomosynthesis provides some of the tomographic benefits of CT but at lower cost and radiation dose than CT. Compared to conventional chest radiography, chest tomosynthesis results in improved visibility of normal structures such as vessels, airway and spine. By reducing visual clutter from overlying normal anatomy, it also enhances detection of small lung nodules. This review article outlines the components of a tomosynthesis system, discusses results regarding improved lung nodule detection from the recent literature, and presents examples of nodule detection from a clinical trial in human subjects. Possible implementation strategies for use in clinical chest imaging are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Survival of Patients with Stage I Lung Cancer Detected on CT Screening
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa060476 · Cited by 1,706
MacMahon, H., Austin, J. H. M., Gamsu, G., Herold, C. J., Jett, J. R., Naidich, D. P., Patz, E. F., & Swensen, S. J. (2005) · Radiology · doi:10.1148/radiol.2372041887 · Cited by 1,574
Cancer risks from diagnostic radiology
HALL, E. J., & BRENNER, D. J. (2008) · The British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 915
CT Screening for Lung Cancer: Frequency and Significance of Part-Solid and Nonsolid Nodules
Henschke, C. I., Yankelevitz, D. F., Mirtcheva, R., McGuinness, G., McCauley, D., & Miettinen, O. S. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.5.1781053 · Cited by 909
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Digital tomosynthesis in breast imaging.
Niklason, L. T., Christian, B. T., Niklason, L. E., Kopans, D. B., Castleberry, D. E., Opsahl-Ong, B. H., Landberg, C. E., Slanetz, P. J., Giardino, A. A., Moore, R., et al. (1997) · Radiology · doi:10.1148/radiology.205.2.9356620 · Cited by 763
Computed Tomography Screening and Lung Cancer Outcomes
Bach, P. B. (2007) · JAMA · doi:10.1001/jama.297.9.953 · Cited by 567
Evaluation of Patients With Pulmonary Nodules: When Is It Lung Cancer?
Gould, M. K., Fletcher, J., Iannettoni, M. D., Lynch, W. R., Midthun, D. E., Naidich, D. P., & Ost, D. E. (2007) · Chest · doi:10.1378/chest.07-1353 · Cited by 503
Evidence for the Treatment of Patients With Pulmonary Nodules: When Is It Lung Cancer?
Wahidi, M. M., Govert, J. A., Goudar, R. K., Gould, M. K., & McCrory, D. C. (2007) · CHEST Journal · doi:10.1378/chest.07-1352 · Cited by 498
Lung cancer detected during a screening program using four-month chest radiographs.
Muhm, J. R., Miller, W. E., Fontana, R. S., Sanderson, D. R., & Uhlenhopp, M. A. (1983) · Radiology · doi:10.1148/radiology.148.3.6308709 · Cited by 344
Tomographic mammography using a limited number of low‐dose cone‐beam projection images
Wu, T., Stewart, A., Stanton, M., McCauley, T., Phillips, W., Kopans, D. B., Moore, R. H., Eberhard, J. W., Opsahl‐Ong, B., Niklason, L., et al. (2003) · Medical Physics · doi:10.1118/1.1543934 · Cited by 302
Lindell, R. M., Hartman, T. E., Swensen, S. J., Jett, J. R., Midthun, D. E., Tazelaar, H. D., & Mandrekar, J. N. (2007) · Radiology · doi:10.1148/radiol.2422052090 · Cited by 297
Recent Advances in Chest Radiography
McAdams, H. P., Samei, E., Dobbins, J., Tourassi, G. D., & Ravin, C. E. (2006) · Radiology · doi:10.1148/radiol.2413051535 · Cited by 200 · cited 4×
“[1] McAdams HP, Samei E, Dobbins 3rd J, Tourassi GD, Ravin CE.”
InfluentialSelf-citationDigital Breast Tomosynthesis: A Pilot Observer Study
Good, W. F., Abrams, G. S., Catullo, V. J., Chough, D. M., Ganott, M. A., Hakim, C. M., & Gur, D. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2841 · Cited by 153
Radiographic screening in the early detection of lung cancer.
Stitik, F. P., & Ms, T. (1978) · PubMed · Cited by 110
Management of an incidentally discovered pulmonary nodule
Beigelman‐Aubry, C., Hill, C., & Greniér, P. (2006) · European Radiology · doi:10.1007/s00330-006-0399-7 · Cited by 86
Evaluation of Linear and Nonlinear Tomosynthetic Reconstruction Methods in Digital Mammography
Suryanarayanan, S., Karellas, A., Vedantham, S., Baker, S. P., Glick, S. J., D’Orsi, C. J., & Webber, R. L. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80530-5 · Cited by 85
Lung Nodule CAD Software as a Second Reader
WHITE, C. S., Pugatch, R. D., Koonce, T., Rust, S. W., & Dharaiya, E. (2008) · Academic Radiology · doi:10.1016/j.acra.2007.09.027 · Cited by 72 · cited 2×
“[8] White CS, Pugatch R, Koonce T, Rust SW, Dharaiya E.”
Tuned Aperture Computed Tomography and Detection of Recurrent Caries
Nair, M. K., Tyndall, D. A., Ludlow, J. B., & May, K. N. (1997) · Caries Research · doi:10.1159/000016426 · Cited by 62
Imaging and Cancer: Research Strategy of the American College of Radiology Imaging Network
Aberle, D. R., Chiles, C., Gatsonis, C., Hillman, B. J., Johnson, C. D., McClennan, B. L., Mitchell, D. G., Pisano, E. D., Schnall, M. D., & Sorensen, A. G. (2005) · Radiology · doi:10.1148/radiol.2353041760 · Cited by 48
CT Screening for Lung Cancer: Past and Ongoing Studies
Henschke, C. I., Shaham, D., Yankelevitz, D. F., & Altorki, N. K. (2005) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/j.semtcvs.2005.05.002 · Cited by 35
Bley, T. A., Baumann, T., Saueressig, U., Pache, G., Treier, M., Schaefer, O., Neitzel, U., Langer, M., & Kotter, E. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318168f705 · Cited by 31
Metadata
- Authors
- Dobbins, J. T., & McAdams, H. P.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 72
- Issue
- 2
- Pages
- 244-251
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2140721130
- Cited by
- 164
- References
- 24
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.