Quality control and whole-gland, zonal and lesion annotations for the PROSTATEx challenge public dataset
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE Radiomic features are promising quantitative parameters that can be extracted from medical images and employed to build machine learning predictive models. However, generalizability is a key concern, encouraging the use of public image datasets. We performed a quality assessment of the PROSTATEx training dataset and provide publicly available lesion, whole-gland, and zonal anatomy segmentation masks. METHOD Two radiology residents and two experienced board-certified radiologists reviewed the 204 prostate MRI scans (330 lesions) included in the training dataset. The quality of provided lesion coordinate was scored using the following scale: 0 = perfectly centered, 1 = within lesion, 2 = within the prostate without lesion, 3 = outside the prostate. All clearly detectable lesions were segmented individually slice-by-slice on T2-weighted and apparent diffusion coefficient images. With the same methodology, volumes of interest including the whole gland, transition, and peripheral zones were annotated. RESULTS Of the 330 available lesion identifiers, 3 were duplicates (1%). From the remaining, 218 received score = 0, 74 score = 1, 31 score = 2 and 4 score = 3. Overall, 299 lesions were verified and segmented. Independently of lesion coordinate score and other issues (e.g., lesion coordinates falling outside DICOM images, artifacts etc.), the whole prostate gland and zonal anatomy were also manually annotated for all cases. CONCLUSION While several issues were encountered evaluating the original PROSTATEx dataset, the improved quality and availability of lesion, whole-gland and zonal segmentations will increase its potential utility as a common benchmark in prostate MRI radiomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599
Turkbey, B., Rosenkrantz, A. B., Haider, M. A., Padhani, A. R., Villeirs, G., Macura, K. J., Tempany, C. M., Choyke, P. L., Cornud, F., Margolis, D. J., et al. (2019) · European Urology · doi:10.1016/j.eururo.2019.02.033 · Cited by 2,544
Exploring Large-scale Public Medical Image Datasets
Oakden-Rayner, L. (2020) · Academic Radiology · doi:10.1016/j.acra.2019.10.006 · Cited by 250
Cited by
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Oncologic Imaging and Radiomics: A Walkthrough Review of Methodological Challenges
Stanzione, A., Cuocolo, R., Ugga, L., Verde, F., Romeo, V., Brunetti, A., & Maurea, S. (2022) · Cancers · doi:10.3390/cancers14194871 · Cited by 64
“should be subject to independent quality controls since the occurrence of shortcomings has been highlighted [23,24].”
BackgroundSelf-citationMust-have Qualities of Clinical Research on Artificial Intelligence and Machine Learning
Koçak, B., Cuocolo, R., Santos, D. P. D., Stanzione, A., & Ugga, L. (2023) · Balkan Medical Journal · doi:10.4274/balkanmedj.galenos.2022.2022-11-51 · Cited by 64
Self-citationPlacenta Accreta Spectrum Disorders and Radiomics: Systematic review and quality appraisal
Stanzione, A., Verde, F., Cuocolo, R., Romeo, V., Paolo Mainenti, P., Brunetti, A., & Maurea, S. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110497 · Cited by 22
Self-citation
Metadata
- Authors
- Cuocolo, R., Stanzione, A., Castaldo, A., De Lucia, D. R., & Imbriaco, M.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 138
- Pages
- 109647
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W3138814803
- Cited by
- 84
- References
- 5
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality control and whole-gland, zonal and lesion annotations for the PROSTATEx challenge public dataset. https://app.cochat.ai/papers/10.1016/j.ejrad.2021.109647
- The paper
- Cuocolo, R., Stanzione, A., Castaldo, A., De Lucia, D. R., & Imbriaco, M. (2021). Quality control and whole-gland, zonal and lesion annotations for the PROSTATEx challenge public dataset. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2021.109647
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.