The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Towards glucose biofuel cells implanted in human body for powering artificial organs: Review
Open accessAbstract
This review summarizes different approaches and breakthroughs of implantable fuel cells from the first noble-metal glucose fuels to the recent use of biocatalysts for selective glucose oxidation and oxygen reduction inside mammal's bodies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Calabrese Barton, S., Gallaway, J., & Atanassov, P. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,394
Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis
Cracknell, J. A., Vincent, K. A., & Armstrong, F. A. (2008) · Chemical Reviews · doi:10.1021/cr0680639 · Cited by 988
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Mediatorless high-power glucose biofuel cells based on compressed carbon nanotube-enzyme electrodes
Zebda, A., Gondran, C., Le Goff, A., Holzinger, M., Cinquin, P., & Cosnier, S. (2011) · Nature Communications · doi:10.1038/ncomms1365 · Cited by 615
Self-citationMano, N., Mao, F., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0346328 · Cited by 573
Implanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
A Glucose BioFuel Cell Implanted in Rats
Cinquin, P., Gondran, C., Giroud, F., Mazabrard, S., Pellissier, A., Boucher, F., Alcaraz, J.-P., Gorgy, K., Lenouvel, F., Mathé, S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010476 · Cited by 413
Self-citationThermoelectric Converters of Human Warmth for Self-Powered Wireless Sensor Nodes
Leonov, V., Torfs, T., Fiorini, P., & Van Hoof, C. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.894917 · Cited by 402
Integrated Enzyme‐Based Biofuel Cells–A Review
Willner, I., Yan, Y. ‐., Willner, B., & Tel‐Vered, R. (2009) · Fuel Cells · doi:10.1002/fuce.200800115 · Cited by 378
Cited by
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Self-citationEnzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
Bandodkar, A. J., You, J.-M., Kim, N.-H., Gu, Y., Kumar, R., Mohan, A. M. V., Kurniawan, J., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 412
Energy Harvesting from the Animal/Human Body for Self-Powered Electronics
Dagdeviren, C., Li, Z., & Wang, Z. L. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044517 · Cited by 348
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Nanostructured material-based biofuel cells: recent advances and future prospects
Zhao, C.-E., Gai, P., Song, R., Chen, Y., Zhang, J., & Zhu, J.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00044d · Cited by 324
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Recent advance in new-generation integrated devices for energy harvesting and storage
Yun, S., Zhang, Y., Xu, Q., Liu, J., & Qin, Y. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.03.074 · Cited by 263
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Stretchable biofuel cell with enzyme-modified conductive textiles
Ogawa, Y., Takai, Y., Kato, Y., Kai, H., Miyake, T., & Nishizawa, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.063 · Cited by 76
Active photonic wireless power transfer into live tissues
Kim, J., Seo, J., Jung, D., Lee, T., Ju, H., Han, J., Kim, N., Jeong, J., Cho, S., Seol, J. H., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2002201117 · Cited by 75
Metadata
- Authors
- Cosnier, S., Le Goff, A., & Holzinger, M.
- Venue
- Electrochemistry Communications
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 38
- Pages
- 19-23
- ISSN
- 1388-2481 (ISSN-L)
- OpenAlex
- W2021733473
- Cited by
- 291
- References
- 27
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.