Electrochemical reduction of carbon dioxide to formic acid at a tin cathode in divided and undivided cells: effect of carbon dioxide pressure and other operating parameters
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The reduction of carbon dioxide to formic acid at a tin cathode was studied in both divided and undivided cells. In the first stage of the study, the effect of some operating parameters, including the working potential and the nature of the supporting electrolyte and of the cathode, on both the cathodic reduction of CO 2 and the anodic oxidation of formic acid was investigated in a divided cell. In a second stage, the reduction of carbon dioxide was performed in an undivided cell with the aim of studying the effect on the generation of formic acid of various operating parameters such as current density, cathode to anode area ratio, mixing rate and nature of the anode and of the supporting electrolyte. A detailed investigation on the effect of the carbon dioxide pressure was also carried out. The utilization of relatively high CO 2 pressures (15–30 bar) allowed to achieve high concentrations of formic acid (up to 0.46 mol L −1 ) working with high current density (up to 90 mA cm −2 ) and using cheap and simple undivided cell and electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hori, Y., Kikuchi, K., & Suzuki, S. (1985) · Chemistry Letters · doi:10.1246/cl.1985.1695 · Cited by 1,401
Agarwal, A. S., Zhai, Y., Hill, D., & Sridhar, N. (2011) · ChemSusChem · doi:10.1002/cssc.201100220 · Cited by 573
Wang, Q., Dong, H., & Yu, H. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.08.017 · Cited by 126
Cited by
Kibria, M. G., Edwards, J. P., Gabardo, C. M., Dinh, C., Seifitokaldani, A., Sinton, D., & Sargent, E. H. (2019) · Advanced Materials · doi:10.1002/adma.201807166 · Cited by 1,331
Electrocatalysis for CO 2 conversion: from fundamentals to value-added products
Wang, G., Chen, J., Ding, Y., Cai, P., Yi, L., Li, Y., Tu, C., Hou, Y., Wen, Z., & Dai, L. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00071j · Cited by 1,295
Li, J., Kuang, Y., Meng, Y., Tian, X., Hung, W.-H., Zhang, X., Li, A., Xu, M., Zhou, W., Ku, C.-S., et al. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c00122 · Cited by 291
Liu, K.-H., Zhong, H.-X., Li, S.-J., Duan, Y.-X., Shi, M.-M., Zhang, X.-B., Yan, J.-M., & Jiang, Q. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.09.001 · Cited by 237
Electrochemical reduction of CO2 into formate/formic acid: A review of cell design and operation
Ewis, D., Arsalan, M., Khaled, M., Pant, D., Ba-Abbad, M. M., Amhamed, A., & El-Naas, M. H. (2023) · Separation and Purification Technology · doi:10.1016/j.seppur.2023.123811 · Cited by 197
Metadata
- Authors
- Scialdone, O., Galia, A., Nero, G. L., Proietto, F., Sabatino, S., & Schiavo, B.
- Venue
- Electrochimica Acta
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 199
- Pages
- 332-341
- ISSN
- 0013-4686 (ISSN-L)
- OpenAlex
- W2281070988
- Cited by
- 103
- References
- 3
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.