Minimizing the environmental impact of PFAS by using specialized coagulants for the treatment of PFAS polluted waters and for the decontamination of firefighting equipment
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Per- and polyfluoroalkyl substances (PFASs) represent an increasingly global challenge for keeping water and soil “non-toxic”. 100 of millions of people are exposed to PFAS levels of concern, in particular, around PFAS production sites and sites where PFASs are/were used and released or disposed. The Stockholm Convention established recommendations to systematically assess PFOS pollution which can be transposed to all PFASs considering that PFASs are an issue of concern under The Strategic Approach to International Chemical Management (SAICM). One major wide-spread source of environmental pollution is the long-term use of PFAS-containing fire extinguishing agents. Strategies for the reduction of human exposure need to reduce and were feasible eliminate the current uses of PFASs and reduce and eliminate the human exposure from the contamination of the environment from past uses including contaminated drinking water. The current study shows that well-known methods of water treatment, especially the use of materials for adsorption and ion exchange, can often neither guarantee satisfactory cleaning results nor economically justifiable filter running times at high PFAS concentrations and complex matrix conditions. Their combination with a pre-precipitation stage using specialized precipitants can significantly optimize treatment successes. PFAS is still being released into the environment in considerable quantities by e.g. the use of so-called aqueous film forming foams (AFFF). Fire departments are increasingly trying to reduce the risks associated with the use of AFFF agents for the health of firefighting personnel and the environment by replacing AFFF foaming agents with fluorine-free foaming agents. If the fluorine-containing foaming agents are simply replaced, considerable residual PFAS loads often remain in the fire extinguishing systems contaminated with PFAS (fire engines, fire boats, stationary fire extinguishing systems, etc.), which are then discharged further into the environment during renewed operations - normally at a reduced concentration. The current study demonstrate that a conscientious decontamination of systems previously in contact with PFAS is therefore urgently required. Here, too, precipitants specialized for PFAS adsorption can make an important contribution to protecting the environment. Sites were firefighting equipment has been cleaned over years can also be considered contaminated and need assessment and possibly remediation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyfluorinated Compounds: Past, Present, and Future
Lindstrom, A. B., Strynar, M. J., & Libelo, E. L. (2011) · Environmental Science & Technology · doi:10.1021/es2011622 · Cited by 1,628
Hu, X. C., Andrews, D. Q., Lindstrom, A. B., Bruton, T. A., Schaider, L. A., Grandjean, P., Lohmann, R., Carignan, C. C., Blum, A., Balan, S. A., et al. (2016) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.6b00260 · Cited by 1,333
Risk to human health related to the presence of perfluoroalkyl substances in food
Panel), E. P. O. C. I. T. F. C. (. C., Schrenk, D., Bignami, M., Bodin, L., Chipman, J. K., del Mazo, J., Grasl‐Kraupp, B., Hogstrand, C., Hoogenboom, L. (., Leblanc, J., et al. (2020) · EFSA Journal · doi:10.2903/j.efsa.2020.6223 · Cited by 989
Barzen-Hanson, K. A., Roberts, S. C., Choyke, S., Oetjen, K., McAlees, A., Riddell, N., McCrindle, R., Ferguson, P. L., Higgins, C. P., & Field, J. A. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.6b05843 · Cited by 873
Half-Lives of PFOS, PFHxS and PFOA after End of Exposure to Contaminated Drinking Water
Li, Y., Fletcher, T., Mucs, D., Scott, K., Lindh, C. H., Tallving, P., & Jakobsson, K. (2018) · Occupational and Environmental Medicine · doi:10.1136/oemed-2017-104651 · Cited by 815
Accumulation of perfluoroalkyl substances in human tissues
Pérez, F., Nadal, M., Navarro-Ortega, A., Fàbrega, F., Domingo, J. L., Barceló, D., & Farré, M. (2013) · Environment International · doi:10.1016/j.envint.2013.06.004 · Cited by 730
Scientific Basis for Managing PFAS as a Chemical Class
Kwiatkowski, C. F., Andrews, D. Q., Birnbaum, L. S., Bruton, T. A., DeWitt, J. C., Knappe, D. R. U., Maffini, M. V., Miller, M. F., Pelch, K. E., Reade, A., et al. (2020) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.0c00255 · Cited by 721
Perfluorinated Surfactants and the Environmental Implications of Their Use in Fire-Fighting Foams
Moody, C. A., & Field, J. A. (2000) · Environmental Science & Technology · doi:10.1021/es991359u · Cited by 707
Do Perfluoroalkyl Compounds Impair Human Semen Quality?
Joensen, U. N., Bossi, R., Leffers, H., Jensen, A. A., Skakkebæk, N. E., & Jørgensen, N. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.0800517 · Cited by 413
Xiao, X., Ulrich, B. A., Chen, B., & Higgins, C. P. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b00970 · Cited by 391
Cited by
Brunn, H., Arnold, G., Körner, W., Rippen, G., Steinhäuser, K. G., & Valentin, I. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00721-8 · Cited by 504
Managing and treating per‐ and polyfluoroalkyl substances (PFAS) in membrane concentrates
Tow, E. W., Ersan, M. S., Kum, S., Lee, T., Speth, T. F., Owen, C., Bellona, C., Nadagouda, M. N., Mikelonis, A. M., Westerhoff, P., et al. (2021) · AWWA Water Science · doi:10.1002/aws2.1233 · Cited by 146
“…coagulant PerfluorAd® uses cationic surfactants to remove anionic PFAS (such as the PFOS found in AFFF-contaminated water) as a pretreatment to other processes such as GAC to extend the lifetime of that downstream process (Cornelsen et al., 2021) and reduce environmental harm (Maga et al., 2021).”
BackgroundMethodInfluentialNg, K., Alygizakis, N., Androulakakis, A., Galani, A., Aalizadeh, R., Thomaidis, N. S., & Slobodnik, J. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129276 · Cited by 88
Phytoremediation prospects of per- and polyfluoroalkyl substances: a review
Mayakaduwage, S., Ekanayake, A., Kurwadkar, S., Rajapaksha, A. U., & Vithanage, M. (2022) · Environmental Research · doi:10.1016/j.envres.2022.113311 · Cited by 65
Metadata
- Authors
- Cornelsen, M., Weber, R., & Panglisch, S.
- Venue
- Emerging Contaminants
- Publisher
- Elsevier BV
- Published
- 2021
- Volume
- 7
- Pages
- 63-76
- ISSN
- 2405-6642 (ISSN-L)
- 2405-6650
- OpenAlex
- W3132936131
- Cited by
- 42
- References
- 16
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimizing the environmental impact of PFAS by using specialized coagulants for the treatment of PFAS polluted waters and for the decontamination of firefighting equipment. https://app.cochat.ai/papers/10.1016/j.emcon.2021.02.001
- The paper
- Cornelsen, M., Weber, R., & Panglisch, S. (2021). Minimizing the environmental impact of PFAS by using specialized coagulants for the treatment of PFAS polluted waters and for the decontamination of firefighting equipment. Emerging Contaminants. https://doi.org/10.1016/j.emcon.2021.02.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.