The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Natural ventilation performance of a double-skin façade with a solar chimney
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Is day natural ventilation still possible in office buildings with a double-skin façade?
Gratia, E., & De Herde, A. (2004) · Building and Environment · doi:10.1016/j.buildenv.2003.10.006 · Cited by 68
Cited by
Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review
Chenari, B., Dias Carrilho, J., & Gameiro da Silva, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.074 · Cited by 515
Urban Physics: Effect of the micro-climate on comfort, health and energy demand
Moonen, P., Defraeye, T., Dorer, V., Blocken, B., & Carmeliet, J. (2012) · Frontiers of Architectural Research · doi:10.1016/j.foar.2012.05.002 · Cited by 379
Perspectives of double skin façades for naturally ventilated buildings: A review
Barbosa, S., & Ip, K. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.192 · Cited by 239
CFD modelling of naturally ventilated double-skin facades with Venetian blinds
Ji, Y., Cook, M. J., Hanby, V., Infield, D. G., Loveday, D. L., & Mei, L. (2008) · Journal of Building Performance Simulation · doi:10.1080/19401490802478303 · Cited by 37
Metadata
- Authors
- Ding, W., Hasemi, Y., & Yamada, T.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2005-04
- Volume
- 37
- Issue
- 4
- Pages
- 411-418
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W1967186516
- Cited by
- 211
- References
- 1
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Natural ventilation performance of a double-skin façade with a solar chimney. https://app.cochat.ai/papers/10.1016/j.enbuild.2004.08.002
- The paper
- Ding, W., Hasemi, Y., & Yamada, T. (2005). Natural ventilation performance of a double-skin façade with a solar chimney. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2004.08.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.