Cited by 68Building Energy and Comfort OptimizationSolar Energy Systems and TechnologiesWind and Air Flow Studies

Is day natural ventilation still possible in office buildings with a double-skin façade?

Gratia, Elisabeth, De Herde, André·2004·Building and Environment

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2003.10.006

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Some design parameters such as solar orientation and prevailing wind direction will be much less sensitive to climate change.

    “Yet, some design parameters such as solar orientation [156] and prevailing wind direction [156,157], will be much less sensitive to climate change.”
  • Double-skin façades are very well developed in the construction sector, from the first Trombe walls in the 1920s to the transparent double-skins for high-rise office buildings (TRL 9).

    “Regarding ventilated surfaces, double-skin façades are very well developed in the construction sector, from the first Trombe walls in the 1920 0 s to the transparent double-skins for high-rise office buildings [158] (TRL 9).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gratia, E., & De Herde, A.
Affiliations
UCLouvain (BE)
Corresponding author
Gratia, Elisabeth
Venue
Building and Environment
Publisher
Elsevier BV
Published
2004-04
Volume
39
Issue
4
Pages
399-409
ISSN
0360-1323 (ISSN-L)
OpenAlex
W2067840050
Cited by
68
References
12
Citations by year
2025: 3 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 6 · 2016: 5 · 2015: 4 · 2014: 5 · 2013: 6 · 2012: 5
FWCI
21.53
Type
journal article
Language
en
Open access
closed
Locations
  • Building and Environment (publishedVersion)
  • Digital Access to Libraries (Université catholique de Louvain (UCL), l'Université de Namur (UNamur) and the Université Saint-Louis (USL-B)) (submittedVersion)
Funders
Gouvernement Wallon
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Solar Energy Systems and Technologies
  • Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
Keywords
double-skin facade, natural ventilation, office buildings, building orientation, wind speed, wind direction, passive cooling, thermal comfort, cooling load reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review