A data-driven state-space model of indoor thermal sensation using occupant feedback for low-energy buildings
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A data-driven state-space Wiener model was developed to characterize the dynamic relation between ambient temperature changes and the resulting occupant thermal sensation. In the proposed state-space model, the mean thermal sensation state variable is governed by a linear dynamic equation driven by changes of ambient temperature and process noise. The output variable, corresponding to occupant actual mean vote, is modeled to be a static nonlinearity of the thermal sensation state corrupted by sensor noise. A chamber experiment was conducted and the collected thermal data and occupants’ thermal sensation votes were used to estimate model coefficients. Then the performance of the proposed Wiener model was evaluated and compared to existing thermal sensation models. In addition, an Extended Kalman Filter (EKF) was applied to use the real-time feedback from occupants to estimate a Wiener model with a time-varying offset parameter, which can be used to adapt the model prediction to environmental and/or occupant variability. Future studies can use this model to dynamically control the Heating Ventilating and Air Conditioning (HVAC) systems to achieve a desired level of thermal comfort for low-energy buildings with actual occupant feedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation with Applications to Tracking and Navigation: Theory, Algorithms and Software
Bar‐Shalom, Y., Li, X. ‐., & Kirubarajan, T. (2002) · doi:10.1002/0471221279 · Cited by 6,782
Extension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733
Skin and core temperature response to partial- and whole-body heating and cooling
Huizenga, C., Zhang, H., Arens, E., & Wang, D. (2004) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2004.08.024 · Cited by 213
Literature review on thermal comfort in transient conditions
Hensen, J. L. M. (1990) · Building and Environment · doi:10.1016/0360-1323(90)90004-b · Cited by 147
Cited by
Kim, J., Schiavon, S., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.023 · Cited by 522
Modeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411
Park, J. Y., & Nagy, Z. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.102 · Cited by 299
LSTM-based indoor air temperature prediction framework for HVAC systems in smart buildings
Mtibaa, F., Nguyen, K.-K., Azam, M., Papachristou, A., Venne, J.-S., & Cheriet, M. (2020) · Neural Computing and Applications · doi:10.1007/s00521-020-04926-3 · Cited by 139
Context-aware Model Predictive Control framework for multi-zone buildings
Mtibaa, F., Nguyen, K.-K., Dermardiros, V., & Cheriet, M. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102340 · Cited by 28
Metadata
- Authors
- Chen, X., Wang, Q., & Srebric, J.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 91
- Pages
- 187-198
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2064169391
- Cited by
- 58
- References
- 5
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A data-driven state-space model of indoor thermal sensation using occupant feedback for low-energy buildings. https://app.cochat.ai/papers/10.1016/j.enbuild.2015.01.038
- The paper
- Chen, X., Wang, Q., & Srebric, J. (2015). A data-driven state-space model of indoor thermal sensation using occupant feedback for low-energy buildings. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2015.01.038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.