Literature review on thermal comfort in transient conditions
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hensen [112] concluded from several studies that if the amplitude of the cyclical variation is larger than 1 K, the acceptable temperature range decreases with increasing variation frequency, and the largest acceptable temperature range is under steady state conditions.
“Hensen [112] concluded from several studies that if the amplitude of the cyclical variation is larger than 1 K, the acceptable temperature range decreases with increasing variation frequency, i.e. larger rate of changes, and the largest acceptable temperature range is under steady state conditions.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [112]
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092 · see citing works
Thermal comfort: Analysis and applications in environmental engineering
Fanger, P. O. (1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,515 · see citing works
Gagge, A. P., Stolwijk, J. A. J., & Hardy, J. D. (1967) · Environmental Research · doi:10.1016/0013-9351(67)90002-3 · Cited by 1,098 · see citing works
A standard predictive index of human response to the thermal environment
Gagge, A. P., Fobelets, A. P. R., & Berglund, L. G. (1986) · ASHRAE winter conference papers · Cited by 1,063 · see citing works
Physiological and behavioral temperature regulation
Hardy, J. D., GAGGE, A. P., & Stolwijk, J. A. J. (1970) · Thomas eBooks · Cited by 673 · see citing works
Thermoreception and temperature regulation
Hensel, H. (1991) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(91)90495-r · Cited by 630 · see citing works
Air turbulence and sensation of draught
Fanger, P. O., Melikov, A. K., Hanzawa, H., et al. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90053-9 · Cited by 532 · see citing works
EVALUATION OF THE PHYSIOLOGICAL BASES OF THERMAL COMFORT MODELS
Doherty, T. J. (1988) · eScholarship (California Digital Library) · Cited by 119 · see citing works
Mathematical Model of thermoregulation
Stolwijk, J. A. J. (1970) · Medical Entomology and Zoology · Cited by 93 · see citing works
Gagge, A. P. (1973) · PubMed · Cited by 61 · see citing works
Spontaneous magnitude estimation of thermal discomfort during changes in the ambient temperature
Wyon, D. P., Andersen, I., & Lundqvist, G. R. (1972) · Journal of Hygiene · doi:10.1017/s0022172400022269 · Cited by 50 · see citing works
EFFECT OF CHANGES IN AMBIENT TEMPERATURE AND LEVEL OF HUMIDITY ON COMFORT AND THERMAL SENSATIONS.
Nevins, R. G., Rr, G., Nishi, Y., et al. (1975) · Cited by 35 · see citing works
The effects of ambient temperature swings on comfort, performance and behaviour.
Wyon, D. P. (1973) · PubMed · Cited by 24 · see citing works
Mcintyre, D. V., & Rr, G. (1976) · Cited by 21 · see citing works
Occupant acceptability of eight-hour-long temperature ramps in the summer at low and high humidities
Berglund, L. G., & Gonzalez, R. R. (1978) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 16 · see citing works
A new “COMECON” standard for thermal comfort within residential and civic buildings
Jokl, M. V. (1986) · International Journal of Biometeorology · doi:10.1007/bf02189447 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733 · see citing works
Schellen, L., Van Marken Lichtenbelt, W. D., Loomans, M. G. L. C., Toftum, J., & De Wit, M. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00657.x · Cited by 377 · see citing works
Thermal pleasure in built environments: physiology of alliesthesia
Parkinson, T., & de Dear, R. (2015) · Building Research & Information · doi:10.1080/09613218.2015.989662 · Cited by 263 · see citing works
Drivers of diversity in human thermal perception – A review for holistic comfort models
Schweiker, M., Huebner, G. M., Kingma, B. R. M., Kramer, R., & Pallubinsky, H. (2018) · Temperature · doi:10.1080/23328940.2018.1534490 · Cited by 231 · see citing works
Thermal comfort of heterogeneous and dynamic indoor conditions — An overview
Mishra, A. K., Loomans, M. G. L. C., & Hensen, J. L. M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.016 · Cited by 167 · see citing works
Self-citationZhang, F., & de Dear, R. (2017) · Indoor Air · doi:10.1111/ina.12296 · Cited by 65 · see citing works
- Authors
- Hensen, J. L. M.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 25
- Issue
- 4
- Pages
- 309-316
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2098955008
- Cited by
- 147
- References
- 18
- Citations by year
- 2026: 10 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 10 · 2021: 12 · 2020: 11 · 2019: 10 · 2018: 15 · 2017: 4 · 2016: 11 · 2015: 9 · 2014: 5 · 2013: 2 · 2012: 1
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Building and Environment (publishedVersion)
- TU/e Research Portal (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Keywords
- thermal comfort, cyclic temperature variation, human thermoregulation, ASHRAE standards, HVAC systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review