A review of internal and external influencing factors on energy efficiency design of buildings
The DOI matches its Crossref record; 98 of the 98 references it cites were found in a registry or an index.
Abstract
Abstract Three main groups of internal and external influencing factors have been identified through this review, including building characteristics, equipment and technologies, and occupant's behaviors. The consideration of only building characteristics cannot guarantee the best energy design of a building, as it could be dependent on the other two groups of factors. Under some circumstances, some of the energy efficiency design solutions did not consider economic or environmental benefits. A wide range of advanced technologies is available for building designers, while challenges still exist from a cost-effectiveness perspective. Many numerical results are hard to validate and confirm the feasibility of those real projects. Comparatively, occupant behavior interventions provide an alternative solution for building users to improve energy efficiency with a relatively low cost and unsophisticated construction procedures. According to those reviewed studies, the ranges of energy-saving are 10–28% and 43–71% through the smart control of the heating, ventilation, and air conditioning (HVAC) and the lighting systems, respectively. The trends of key influencing factors on energy efficiency design have slightly changed over the past few decades. The influencing factors had been mainly investigated in the optimization design and technological updates of buildings previously but now have incorporated the building management of occupant behavior. Few studies have been carried out to integrate the occupant behavior model into the current energy simulation software. Thus, two research directions can be concluded after this review. Building efficiency design needs to be conducted from a systematic view to figure out the underlying issues among different efficient design measures. Energy performance benchmarking of both occupant behavior interventions and the technological updates and building service systems are urgently needed as a guided reference to help the building users to make smart decisions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of intervention studies aimed at household energy conservation
Abrahamse, W., Steg, L., Vlek, C., & Rothengatter, T. (2005) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2005.08.002 · Cited by 2,668
A review on the prediction of building energy consumption
Zhao, H.-X., & Magoulès, F. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.049 · Cited by 1,937
Contrasting the capabilities of building energy performance simulation programs
Crawley, D. B., Hand, J. W., Kummert, M., & Griffith, B. T. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.10.027 · Cited by 1,858
Al-Homoud, D. M. S. (2005) · Building and Environment · doi:10.1016/j.buildenv.2004.05.013 · Cited by 1,019
Energy Simulation in Building Design
Clarke, J. (2007) · Routledge eBooks · doi:10.4324/9780080505640 · Cited by 964
On the impact of urban climate on the energy consumption of buildings
Santamouris, M., Papanikolaou, N., Livada, I., Koronakis, I., Georgakis, C., Argiriou, A., & Assimakopoulos, D. N. (2001) · Solar Energy · doi:10.1016/s0038-092x(00)00095-5 · Cited by 911
State of the art in building modelling and energy performances prediction: A review
Foucquier, A., Robert, S., Suard, F., Stéphan, L., & Jay, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.004 · Cited by 832
A review on insulation materials for energy conservation in buildings
Aditya, L., Mahlia, T. M. I., Rismanchi, B., Ng, H. M., Hasan, M. H., Metselaar, H. S. C., Muraza, O., & Aditiya, H. B. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.034 · Cited by 811
A review of data-driven approaches for prediction and classification of building energy consumption
Wei, Y., Zhang, X., Shi, Y., Xia, L., Pan, S., Wu, J., Han, M., & Zhao, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.108 · Cited by 803
Guerra Santin, O., Itard, L., & Visscher, H. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.07.002 · Cited by 762
Heating, Ventilating, and Air Conditioning: Analysis and Design
McQuiston, F. C., & Parker, J. D. (1977) · Cited by 742
General review of ground-source heat pump systems for heating and cooling of buildings
Sârbu, I., & Sebarchievici, C. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.11.068 · Cited by 716
Wang, Z., & Srinivasan, R. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.10.079 · Cited by 678
Energy efficient design of building: A review
Pacheco, R., Ordóñez, J., & Martínez, G. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.045 · Cited by 645
Neto, A. H., & Fiorelli, F. A. S. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.06.013 · Cited by 611
Kavousian, A., Rajagopal, R., & Fischer, M. (2013) · Energy · doi:10.1016/j.energy.2013.03.086 · Cited by 591
Occupancy-driven energy management for smart building automation
Agarwal, Y., Balaji, B., Gupta, R., Lyles, J., Wei, M., & Weng, T. (2010) · Proceedings of the 2nd ACM Workshop on Embedded Sensing Systems for Energy-Efficiency in Building · doi:10.1145/1878431.1878433 · Cited by 570
Zero energy buildings and sustainable development implications – A review
Li, D. H. W., Yang, L., & Lam, J. C. (2013) · Energy · doi:10.1016/j.energy.2013.01.070 · Cited by 564
Artificial neural networks for the prediction of the energy consumption of a passive solar building
Kalogirou, S. A. (2000) · Energy · doi:10.1016/s0360-5442(99)00086-9 · Cited by 533
A review of different strategies for HVAC energy saving
Vakiloroaya, V., Samali, B., Fakhar, A., & Pishghadam, K. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.10.023 · Cited by 521
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
Yan, D., Hong, T., Dong, B., Mahdavi, A., D’Oca, S., Gaetani, I., & Feng, X. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.084 · Cited by 508
A review of the economical and optimum thermal insulation thickness for building applications
Kaynaklı, Ö. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.08.006 · Cited by 497
Abanda, F. H., & Byers, L. (2016) · Energy · doi:10.1016/j.energy.2015.12.135 · Cited by 472
Predicting future hourly residential electrical consumption: A machine learning case study
Edwards, R. E., New, J., & Parker, L. E. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.03.010 · Cited by 391
Yu, J., Yang, C., Tian, L., & Liao, D. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.03.010 · Cited by 378
Future trends of building heating and cooling loads and energy consumption in different climates
Wan, K. K. W., Li, D. H. W., Liu, D., & Lam, J. C. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.07.016 · Cited by 371
Coordinating occupant behavior for building energy and comfort management using multi-agent systems
Klein, L., Kwak, J.-Y., Kavulya, G., Jazizadeh, F., Becerik-Gerber, B., Varakantham, P., & Tambe, M. (2012) · Automation in Construction · doi:10.1016/j.autcon.2011.11.012 · Cited by 367
Li, Q., Meng, Q., Cai, J., Yoshino, H., & Mochida, A. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.08.033 · Cited by 359
Energy efficient building environment control strategies using real-time occupancy measurements
Erickson, V. L., Lin, Y., Kamthe, A. U., Brahme, R., Surana, A., Cerpa, A., Sohn, M. D., & Narayanan, S. (2009) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/1810279.1810284 · Cited by 356
Fuentes, E., Arce, L., & Salom, J. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.229 · Cited by 343
Bolattürk, A. (2007) · Building and Environment · doi:10.1016/j.buildenv.2007.02.014 · Cited by 340
Using machine learning techniques for occupancy-prediction-based cooling control in office buildings
Peng, Y., Rysanek, A., Nagy, Z., & Schlüter, A. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.002 · Cited by 332
Bohdanowicz, P., & Martinac, I. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.05.005 · Cited by 323
Wang, S., & Xu, X. (2006) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2005.06.009 · Cited by 308
Lee, J. W., Jung, H. J., Park, J. Y., Lee, J. B., & Yoon, Y. (2013) · Renewable Energy · doi:10.1016/j.renene.2012.07.029 · Cited by 308
Daouas, N. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.07.030 · Cited by 303
Design of buildings shape and energetic consumption
Depecker, P., Menezo, C., Virgone, J., & Lepers, S. (2001) · Building and Environment · doi:10.1016/s0360-1323(00)00044-5 · Cited by 294
Experimental study on the performance of insulation materials in Mediterranean construction
Cabeza, L. F., Castell, A., Medrano, M., Martorell, I., Pérez, G., & Fernández, I. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2009.10.033 · Cited by 277
Computer-aided building energy analysis techniques
Al-Homoud, M. S. (2001) · Building and Environment · doi:10.1016/s0360-1323(00)00026-3 · Cited by 275
Niu, J. L., Zhang, L. Z., & Zuo, H. G. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(01)00132-3 · Cited by 264
Reddy, T. A. (2006) · ASHRAE winter conference papers · Cited by 253
Influence of insulation configuration on heating and cooling loads in a continuously used building
Kossecka, E., & Kosny, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(01)00121-9 · Cited by 248
De Rosa, M., Bianco, V., Scarpa, F., & Tagliafico, L. A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.067 · Cited by 243
Measures used to lower building energy consumption and their cost effectiveness
Florides, G. A., Tassou, S. A., Kalogirou, S. A., & Wrobel, L. C. (2002) · Applied Energy · doi:10.1016/s0306-2619(02)00119-8 · Cited by 242
Morrissey, J. E., Moore, T., & Horne, R. E. (2010) · Renewable Energy · doi:10.1016/j.renene.2010.08.013 · Cited by 239
Lighting energy savings in offices using different control systems and their real consumption
Roisin, B., Bodart, M., Deneyer, A., & D’Herdt, P. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.04.006 · Cited by 237
A hybrid model approach for forecasting future residential electricity consumption
Dong, B., Li, Z., Rahman, S. M. M., & Vega, R. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.09.033 · Cited by 229
Gasparella, A., Pernigotto, G., Cappelletti, F., Romagnoni, P., & Baggio, P. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.12.032 · Cited by 207
Mahlia, T. M. I., Taufiq, B. N., Ismail, & Masjuki, H. H. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.06.002 · Cited by 206
Kwok, S. S. K., & Lee, E. W. M. (2011) · Energy Conversion and Management · doi:10.1016/j.enconman.2011.02.002 · Cited by 197
Effects of Global Warming on Energy Use for Space Heating and Cooling in the United States
Rosenthal, D. H., Gruenspecht, H. K., & Moran, E. A. (1995) · The Energy Journal · doi:10.5547/issn0195-6574-ej-vol16-no2-4 · Cited by 194
Effects of occupancy and lighting use patterns on lighting energy consumption
Yun, G. Y., Kim, H., & Kim, J. T. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2011.10.034 · Cited by 193
Boyano, A., Hernandez, P., & Wolf, O. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.05.039 · Cited by 189
Monitoring-based HVAC commissioning of an existing office building for energy efficiency
Wang, L., Greenberg, S., Fiegel, J., Rubalcava, A., Earni, S., Pang, X., Yin, R., Woodworth, S., & Hernandez-Maldonado, J. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.09.005 · Cited by 189
Hong, T., Koo, C., Kim, J., Lee, M., & Jeong, K. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.06.043 · Cited by 188
Sisman, N., Kahya, E., Aras, N., & Aras, H. (2007) · Energy Policy · doi:10.1016/j.enpol.2007.04.037 · Cited by 180
Kelly, S. (2011) · Energy · doi:10.1016/j.energy.2011.07.009 · Cited by 177
A systematic approach to occupancy modeling in ambient sensor-rich buildings
Yang, Z., Li, N., Becerik-Gerber, B., & Orosz, M. (2014) · SIMULATION · doi:10.1177/0037549713489918 · Cited by 174
Impact of building shape on thermal performance of office buildings in Kuwait
AlAnzi, A., Seo, D., & Krarti, M. (2009) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.09.033 · Cited by 174
The effect of window opening ventilation control on residential building energy consumption
Sorgato, M. J., Melo, A. P., & Lamberts, R. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.09.059 · Cited by 170
Nik, V. M., & Kalagasidis, A. S. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.11.005 · Cited by 169
A prediction model based on neural networks for the energy consumption of a bioclimatic building
Mena-Yedra, R., Rodríguez, F., Castilla, M., & Arahal, M. R. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.052 · Cited by 167
Zhang, L. (2001) · Energy · doi:10.1016/s0360-5442(00)00064-5 · Cited by 163
An applied artificial intelligence approach towards assessing building performance simulation tools
Yezioro, A., Dong, B., & Leite, F. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.04.014 · Cited by 159
Daylight, sunlight and solar gain in the urban environment
Littlefair, P. J. (2001) · Solar Energy · doi:10.1016/s0038-092x(00)00099-2 · Cited by 152
Effect of thermal conductivities of shape stabilized PCM on under-floor heating system
Cheng, W.-L., Xie, B., Zhang, R., Xu, Z., & Xia, Y. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.055 · Cited by 151
Konstantakopoulos, I. C., Barkan, A. R., He, S., Veeravalli, T., Liu, H., & Spanos, C. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.065 · Cited by 145
Impact of glazing to wall ratio in various climatic regions: A case study
Alwetaishi, M. (2017) · Journal of King Saud University - Engineering Sciences · doi:10.1016/j.jksues.2017.03.001 · Cited by 140
Gaterell, M. R., & McEvoy, M. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.12.015 · Cited by 135
A methodology for identifying and improving occupant behavior in residential buildings
Yu, Z. J., Haghighat, F., Fung, B. C. M., Morofsky, E., & Yoshino, H. (2011) · Energy · doi:10.1016/j.energy.2011.09.002 · Cited by 134
Bojic, M. L., Yik, F. W. H., & Sat, P. S. K. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00125-0 · Cited by 134
Baldi, S., Korkas, C. D., Lv, M., & Kosmatopoulos, E. B. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.09.188 · Cited by 132
Dong, B., & Lam, K. P. (2011) · Journal of Building Performance Simulation · doi:10.1080/19401493.2011.577810 · Cited by 132
Co-simulation of innovative integrated HVAC systems in buildings
Trcka, M. M., Hensen, J. J., & Wetter, M. (2009) · Journal of Building Performance Simulation · doi:10.1080/19401490903051959 · Cited by 131
Yang, Z., Ghahramani, A., & Becerik-Gerber, B. (2016) · Energy · doi:10.1016/j.energy.2016.04.099 · Cited by 125
Effects of Climate Change on Commercial Building Energy Demand
SCOTT, M. J., Wrench, L. E., & Hadley, D. L. (1994) · Energy Sources · doi:10.1080/00908319408909081 · Cited by 124
Theoretical evaluation of thermal and energy performance of tropical green roofs
Tsang, S. W., & Jim, C. Y. (2011) · Energy · doi:10.1016/j.energy.2011.03.072 · Cited by 118
Turhan, C., Kazanasmaz, T., Uygun, İ. E., Ekmen, K. E., & Akkurt, G. G. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.09.026 · Cited by 107
Impact of climate change on the design of energy efficient residential building envelopes
Karimpour, M., Belusko, M., Xing, K., Boland, J. W., & Bruno, F. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.10.064 · Cited by 105
Yousefi, F., Gholipour, Y., & Yan, W. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.04.085 · Cited by 103
Francisco, A., Truong, H., Khosrowpour, A., Taylor, J. E., & Mohammadi, N. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.03.132 · Cited by 96
A thermal performance parametric study of window type, orientation, size and shadowing effect
Amaral, A. R., Rodrigues, E. M. D. S., Gaspar, A. R., & Gomes, Á. (2016) · Sustainable Cities and Society · doi:10.1016/j.scs.2016.05.014 · Cited by 86
Optimisation of building shape and orientation for better energy efficient architecture
Fallahtafti, R., & Mahdavinejad, M. (2015) · International Journal of Energy Sector Management · doi:10.1108/ijesm-09-2014-0001 · Cited by 82
Generalizable occupant-driven optimization model for domestic hot water production in NZEB
Kazmi, H., D’Oca, S., Delmastro, C., Lodeweyckx, S., & Corgnati, S. P. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.04.108 · Cited by 80
Gouveia, J. P., Fortes, P., & Seixas, J. (2012) · Energy · doi:10.1016/j.energy.2012.09.042 · Cited by 79
Langevin, J., Wen, J., & Gurian, P. L. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.09.026 · Cited by 75
Pedersen, L. (2005) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2005.08.005 · Cited by 73
Need for thermal-storage air-conditioning in Saudi Arabia
Hasnain, S. M., & Al-Abbadi, N. M. (2000) · Applied Energy · doi:10.1016/s0306-2619(99)00107-5 · Cited by 70
Assessing cooling energy performance of windows for office buildings in the Mediterranean zone
Tsikaloudaki, K., Laskos, K., Theodosiou, T. G., & Bikas, D. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.02.004 · Cited by 69
An ice thermal storage computer model
Chaichana, C., Charters, W. W. S., & Aye, L. (2001) · Applied Thermal Engineering · doi:10.1016/s1359-4311(01)00046-1 · Cited by 68
Hybrid vapor compression refrigeration system with an integrated ejector cooling cycle
Zhu, Y., & Jiang, P. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.09.003 · Cited by 68
Aerogel vs. argon insulation in windows: A greenhouse gas emissions analysis
Lolli, N., & Andresen, I. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.03.001 · Cited by 61
Ahn, J., & Cho, S. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.06.079 · Cited by 59
Xamán, J., Olazo-Gómez, Y., Zavala-Guillén, I., Hernández–Pérez, I., Ortegón-Aguilar, J., & Hinojosa, J. F. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.08.156 · Cited by 57
Khosrowpour, A., Jain, R. K., Taylor, J. E., Peschiera, G., Chen, J., & Gulbinas, R. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.148 · Cited by 53
Reflective multi-foil insulations for buildings: A review
Tenpierik, M., & Hasselaar, E. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.10.003 · Cited by 53
Yoo, S., Jeong, H., Ahn, B.-L., Han, H., Seo, D., Lee, J., & Jang, C.-Y. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.08.005 · Cited by 33
Wang, S., Kim, A. A., & Johnson, E. M. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.01.082 · Cited by 22
Cited by
Plörer, D., Hammes, S., Hauer, M., van Karsbergen, V., & Pfluger, R. (2021) · Energies · doi:10.3390/en14133852 · Cited by 42
Metadata
- Authors
- Chen, S., Zhang, G., Xia, X., Setunge, S., & Shi, L.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 216
- Pages
- 109944
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3010854018
- Cited by
- 184
- References
- 98
- FWCI
- 12.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.