A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract Radiant heating and cooling (RHC) systems typically work together with ventilation systems in order to take care of sensible loads, latent loads and pollutants. There are various combinations according to the location of radiant surfaces and air distribution principles. Even though there are extensive researches on radiant systems and ventilation systems individually, the design and performance of the integrated systems have not been discussed systematically. The objective of this paper is to summarize the integrated system configurations in the building environment from both scientific researches and practical applications, and to identify the system characteristics and suitable application area. The focus of this paper is on thermal comfort and indoor air quality and the critical design parameters that have impacts on these two aspects, such as location and amount of heat sources, contaminant source types, room geometry, and condensation risk. Design recommendation has been given at the end for selecting and designing the integrated systems, which is intended to be used by system designers, engineers, and architects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydronic radiant cooling — preliminary assessment
Feustel, H. E., & Stetiu, C. (1995) · Energy and Buildings · doi:10.1016/0378-7788(95)00922-k · Cited by 237
Effects of different cooling principles on thermal sensation and physiological responses
Schellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.01.007 · Cited by 46
Cited by
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Self-citation
Metadata
- Authors
- Zhang, C., Pomianowski, M., Heiselberg, P. K., & Yu, T.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 223
- Pages
- 110094
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3024190013
- Cited by
- 182
- References
- 2
- FWCI
- 12.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality. https://app.cochat.ai/papers/10.1016/j.enbuild.2020.110094
- The paper
- Zhang, C., Pomianowski, M., Heiselberg, P. K., & Yu, T. (2020). A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2020.110094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.