Random forest based intelligent fault diagnosis for PV arrays using array voltage and string currents

Chen, Zhicong, Han, Fuchang, Wu, Lijun, Yu, Jinling, Cheng, Shuying, Lin, Peijie, Chen, Huihuang·2018·Energy Conversion and Management

Abstract

Abstract With the rapid growth of installed capacity of photovoltaic power systems, status monitoring and fault diagnosis of PV arrays becomes increasingly important for improving the energy conversion and maintenance efficiency. In recent years, many machine learning algorithms were successfully applied to automatically build fault diagnosis models using the fault data samples. However, most of them suffer overfitting problem and the generalization performance is still limited. In this paper, the random forest (RF) ensemble learning algorithm is explored for the detection and diagnosis of PV arrays early faults (including line-line faults, degradation, open circuit, and partial shading), which combines multiple learning algorithms to achieve a superior diagnostic performance. The proposed RF based fault diagnosis model only takes the real-time operating voltage and string currents of the PV arrays as the fault features, which is irrelevant to the environment conditions. In addition, a grid-search method is used to optimize the parameters of the RF model by minimizing the out-of-bag error estimation, so as to improve the fault diagnosis model. In order to obtain sufficient fault data samples, comprehensive fault experiments are conducted on both a Simulink based simulated PV system and a laboratory PV system. The simulation and experimental results both demonstrate that the optimized RF based fault diagnosis model can achieve a high overall detection and diagnosis performance. Moreover, the comparison results indicate that the generalization performance of the proposed RF based model is better than the one of the decision tree based model. Therefore, the proposed optimal RF based method is an effective and efficient alternative to detect and classify the faults of PV arrays. Furthermore, the proposed RF based fault diagnosis model is successfully integrated into a Matlab based real-time monitoring system prototype developed for the laboratory PV system, which validates the practicability as well.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2018.10.040

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

See all 320

Metadata

Authors
Chen, Z., Han, F., Wu, L., Yu, J., Cheng, S., Lin, P., & Chen, H.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2018-12
Volume
178
Pages
250-264
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2897996667
Cited by
320
References
45
FWCI
5.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Random forest based intelligent fault diagnosis for PV arrays using array voltage and string currents. https://app.cochat.ai/papers/10.1016/j.enconman.2018.10.040
The paper
Chen, Z., Han, F., Wu, L., Yu, J., Cheng, S., Lin, P., & Chen, H. (2018). Random forest based intelligent fault diagnosis for PV arrays using array voltage and string currents. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2018.10.040

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.