The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Integrated sizing of hybrid PV-wind-battery system for remote island considering the saturation of each renewable energy resource
Abstract
The proliferation of renewable energy particularly the combination of solar-wind power and storage bank, is likely to be occupied throughout the world, to mitigate the local energy concerns, improve the energy supply opportunities for off-grid communities and vitiate environmental pollution concerns as well as ease the intensity of energy consumption. To mitigate the disharmony between renewable energy (RE) generation and supply, a cost-optimal autonomous hybrid renewable energy system is developed and comparatively analyzed, considering the saturation level of each involved RE source based on various technical and economic key indicators. This study proposes a mathematical model to comprehensively analyze the effect of varying saturation, i.e. increasing the saturation of one resource meanwhile decreasing the ratio of other resource, on battery bank size, state of charge (SOC), loss of power supply, excess energy, net present cost, levelized cost of energy (COE) and payback time. A saturation factor is introduced, from 0 to 1 value with step size 0.02, where zero represents the wind-only system and one represents the solar-only system. Three different systems are considered, with different wind turbine sizes (total 150 configurations), to comparatively analyze the different energy systems and the result reveals that smaller wind turbine size (2 kW) with 90% saturation of wind energy is the most cost-effective system for the proposed remote island. In addition, the solar-alone and wind-alone systems are compared, showing that the wind-only system can provide good performance as compare to solar-only. Furthermore, the effects of the saturation factor on COE, battery bank size, SOC, excess energy, system reliability and different load demands are analyzed. Energy balance analysis of whole year and simulation performance of the system is accomplished to verify the system reliability. Sensitivity analysis reveals that wind energy, battery cost and load has a significant impact on COE than other factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lead batteries for utility energy storage: A review
May, G. J., Davidson, A., & Monahov, B. (2018) · Journal of Energy Storage · doi:10.1016/j.est.2017.11.008 · Cited by 1,038
Micropower System Modeling with Homer
Lambert, T., Gilman, P., & Lilienthal, P. (2005) · Integration of Alternative Sources of Energy · doi:10.1002/0471755621.ch15 · Cited by 807
Chauhan, A., & Saini, R. P. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.079 · Cited by 792
A feasibility study of a stand-alone hybrid solar–wind–battery system for a remote island
Ma, T., Yang, H., & Lu, L. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.01.090 · Cited by 575
Self-citationSingh, S., Singh, M. K., & Kaushik, S. C. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.09.046 · Cited by 490
Optimization of micro-grid system using MOPSO
Borhanazad, H., Mekhilef, S., Ganapathy, V., Modiri-Delshad, M., & Mirtaheri, A. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.05.006 · Cited by 479
A review of renewable energy utilization in islands
Kuang, Y., Zhang, Y., Zhou, B., Li, C., Cao, Y., Li, L., & Zeng, L. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.014 · Cited by 467
Dufo‐López, R., Bernal-Agustín, J. L., Yusta, J. M., Dominguez-Navarro, J. A., Ramírez-Rosado, I. J., Lujano, J., & Aso, I. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.04.019 · Cited by 460
Ma, T., Yang, H., Lu, L., & Peng, J. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.03.028 · Cited by 407
Self-citationMa, T., Yang, H., Lu, L., & Peng, J. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.06.005 · Cited by 385
Self-citationZhao, B., Zhang, X., Li, P., Wang, K., Xue, M., & Wang, C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.09.015 · Cited by 380
Ma, T., Yang, H., & Lu, L. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.12.047 · Cited by 351
Self-citationIsmail, M. S., Moghavvemi, M., & Mahlia, T. M. I. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.02.005 · Cited by 346
Kalinci, Y., Hepbasli, A., & Dincer, I. (2015) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2014.10.147 · Cited by 342
Optimization of Pumped Storage Capacity in an Isolated Power System With Large Renewable Penetration
Brown, P. D., Peas Lopes, J. A., & Matos, M. A. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.919419 · Cited by 289
Maleki, A., & Askarzadeh, A. (2014) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2014.04.147 · Cited by 270
Ma, T., Yang, H., & Lu, L. (2014) · Solar Energy · doi:10.1016/j.solener.2013.12.003 · Cited by 264
Self-citationOptimal design of an autonomous solar–wind-pumped storage power supply system
Ma, T., Yang, H., Lu, L., & Peng, J. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.11.026 · Cited by 257
Self-citationMaleki, A., & Askarzadeh, A. (2014) · Solar Energy · doi:10.1016/j.solener.2014.05.016 · Cited by 213
Ahmadi, S., & Abdi, S. (2016) · Solar Energy · doi:10.1016/j.solener.2016.05.019 · Cited by 209
Askarzadeh, A., & dos Santos Coelho, L. (2015) · Solar Energy · doi:10.1016/j.solener.2014.12.013 · Cited by 208
Maleki, A., Ameri, M., & Keynia, F. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.02.045 · Cited by 198
Zhou, X., & Feng, C. (2017) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2016.10.152 · Cited by 164
Gioutsos, D. M., Blok, K., van Velzen, L., & Moorman, S. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.05.108 · Cited by 127
Increasing the penetration of renewable energy resources in S. Vicente, Cape Verde
Segurado, R., Krajačić, G., Duić, N., & Alves, L. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.07.005 · Cited by 124
Khan, M. R. B., Jidin, R., Pasupuleti, J., & Shaaya, S. A. (2015) · Energy · doi:10.1016/j.energy.2014.12.072 · Cited by 122
Kapsali, M., Anagnostopoulos, J. S., & Kaldellis, J. K. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.05.054 · Cited by 121
Gupta, R., Kumar, R., & Bansal, A. K. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.09.017 · Cited by 105
A mobile off-grid platform powered with photovoltaic/wind/battery/fuel cell hybrid power systems
Yazici, M. S., Yavaşoğlu, H. A., & Eroglu, M. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.04.025 · Cited by 83
Study on stand-alone power supply options for an isolated community
Ma, T., Yang, H., & Lu, L. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.09.023 · Cited by 73
Self-citationWang, H., Wang, H., Haijian, Z., & Zhu, T. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.10.078 · Cited by 70
Optimal Sizing Design and Energy Management of Stand-alone Photovoltaic/Wind Generator Systems
Tegani, I., Aboubou, A., Ayad, M. Y., Becherif, M., Saadi, R., & Kraa, O. (2014) · Energy Procedia · doi:10.1016/j.egypro.2014.06.020 · Cited by 60
Cited by
Solar and wind power generation systems with pumped hydro storage: Review and future perspectives
Javed, M. S., Ma, T., Jurasz, J., & Amin, M. Y. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.11.157 · Cited by 482
Self-citationXu, C., Ke, Y., Li, Y., Chu, H., & Wu, Y. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.112892 · Cited by 386
Hybrid pumped hydro and battery storage for renewable energy based power supply system
Javed, M. S., Zhong, D., Ma, T., Song, A., & Ahmed, S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114026 · Cited by 278
Self-citationJaved, M. S., Song, A., & Ma, T. (2019) · Energy · doi:10.1016/j.energy.2019.03.131 · Cited by 264
Self-citationMokhtara, C., Negrou, B., Bouferrouk, A., Yao, Y., Settou, N., & Ramadan, M. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.113192 · Cited by 253
Metadata
- Authors
- Ma, T., & Javed, M. S.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 182
- Pages
- 178-190
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2907232347
- Cited by
- 282
- References
- 32
- FWCI
- 13.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.