Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 275

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Techno-economic optimization of an off-grid hybrid renewable energy system using metaheuristic optimization approaches – Case of a radio transmitter station in India

Das, Monotosh, Singh, Maisanam Anil Kumar, Biswas, Agnimitra·2019·Energy Conversion and Management

Abstract

Abstract Development of hybrid renewable energy system has become a challenging task considering the intermittencies of renewables and multi-dimensional designing aspects (for example technical and economic aspects) of such hybrid systems. Although there are many investigations on the development of hybrid renewable energy systems, the investigations of useful models or effective methods are only a few. Metaheuristic algorithms are gaining much popularity in the optimization of complex systems like hybrid renewable energy system for their ability to give quick, accurate, and optimal solution. The objective of the present study is to obtain a techno-economic optimal design of an off-grid hybrid solar photovoltaic/biogas generator/pumped hydro energy storage/battery system with the help of metaheuristic optimization techniques for a radio transmitter station in India. Performances of two such techniques – water cycle algorithm and moth-flame optimization that have become popular in recent time are evaluated and compared with Genetic Algorithm, which was used as a benchmark metaheuristic in previous studies on hybrid renewable energy system. The objective function is a minimization of total net present cost subject to design constraints. A detailed modeling strategy has been elaborated for the optimization problem. A sensitivity analysis based on loss of load probability type reliability criteria is carried out to investigate the feasibility of the proposed design. The results show that both the considered metaheuristics are effective in finding the optimal design; however, water cycle algorithm has marginally better design solution than the other two algorithms. The optimal configuration by the water cycle algorithm is found to have solar photovoltaic panel area of 548.67 m2 (size 69.2 kW), biogas generator size of 16 kW, battery bank of 21 units, converter size of 30 kW, and upper reservoir volume of 2081.5 m3 with a total net present cost of $0.813 million. Further, on comparing the results with literature, it is found that the present metaheuristic optimization has resulted in an effective hybrid renewable energy system design with a lower techno-economic cost.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2019.01.107

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 275

Metadata

Authors
Das, M., Singh, M. A. K., & Biswas, A.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2019-04
Volume
185
Pages
339-352
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2915637638
Cited by
275
References
50
FWCI
13.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Techno-economic optimization of an off-grid hybrid renewable energy system using metaheuristic optimization approaches – Case of a radio transmitter station in India. https://app.cochat.ai/papers/10.1016/j.enconman.2019.01.107
The paper
Das, M., Singh, M. A. K., & Biswas, A. (2019). Techno-economic optimization of an off-grid hybrid renewable energy system using metaheuristic optimization approaches – Case of a radio transmitter station in India. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2019.01.107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.