Passive options for solar cooling of buildings in arid areas

Amer, Emad H.·2006·Energy

Overview

Integrity signals

Registry

Crossref · 10.1016/j.energy.2005.06.002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 14

  1. Duffin, 1984, A passive wall design to minimize building temperature swings, Sol Energy, 33, 337, 10.1016/0038-092X(84)90163-4 · DOI
  2. Hay, 1969, International aspects of air conditioning with movable insulation, Sol Energy, 12, 427, 10.1016/0038-092X(69)90065-6 · DOI
  3. Niles, 1976, Thermal evaluation of a house using a movable insulation heating and cooling, Sol Energy, 18, 413, 10.1016/0038-092X(76)90007-4 · DOI
  4. Ohanessian, 1978, Thermal insulation of a passive solar house using a Trombe Michel wall, Sol Energy, 20, 275, 10.1016/0038-092X(78)90106-8 · DOI
  5. Robbins, 1980, Computer modeling of ventilated Trombe wall with actual performance data, Sol Energy, 25, 207, 10.1016/0038-092X(80)90325-4 · DOI
  6. Bilgen, 1982, Solar heating–ventilating system using a solar chimney, Sol Energy, 28, 227, 10.1016/0038-092X(82)90161-X · DOI
  7. Yadav, 1983, Digital simulation of indoor temperatures of buildings with roof ponds, Sol Energy, 31, 205, 10.1016/0038-092X(83)90083-X · DOI
  8. Sodha, 1978, Reduction of heat flux through a roof by water film, Sol Energy, 20, 189, 10.1016/0038-092X(78)90196-2 · DOI
  9. Chandra, 1983, Temperature control in building with evaporated cooling and variable ventilation, Sol Energy, 30, 381, 10.1016/0038-092X(83)90193-7 · DOI
  10. Givoni, 1991, Characteristics, design implications and applicability of passive solar systems, Sol Energy, 47, 425, 10.1016/0038-092X(91)90110-I · DOI
  11. Onmura, 2001, Study on evaporative cooling effect of roof lawn gardens, Energy and Buildings, 33, 653, 10.1016/S0378-7788(00)00134-1 · DOI
  12. Jiang, 2001, A solar cooling project for hot and humid climates, Sol Energy, 70, 135
  13. Raman, 2001, A passive solar system for thermal comfort conditioning of buildings in composite climates, Sol Energy, 70, 319, 10.1016/S0038-092X(00)00147-X · DOI
  14. Florides, 2002, Measures used to lower building energy consumption and their cost effectiveness, Appl Energy, 73, 299, 10.1016/S0306-2619(02)00119-8 · DOI

Cited by

Sorted by citations

See all 72

Metadata

Authors
Amer, E. H.
Affiliations
Menoufia University (EG)
Corresponding author
Amer, Emad H.
Venue
Energy
Publisher
Elsevier BV
Published
2006-07
Volume
31
Issue
8-9
Pages
1332-1344
ISSN
0360-5442 (ISSN-L)
OpenAlex
W2019889385
Cited by
72
References
0
Citations by year
2026: 1 · 2025: 4 · 2024: 9 · 2023: 2 · 2022: 2 · 2021: 8 · 2020: 7 · 2019: 4 · 2018: 9 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 5
FWCI
2.37
Type
journal article
Language
en
Open access
closed
Locations
  • Energy (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
Keywords
passive solar cooling, building thermal load, arid climate, indoor temperature, thermal insulation, evaporative cooling, solar chimney, metal structures, workshops

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Passive options for solar cooling of buildings in arid areas. https://app.cochat.ai/papers/10.1016/j.energy.2005.06.002
The paper
Amer, E. H. (2006). Passive options for solar cooling of buildings in arid areas. Energy. https://doi.org/10.1016/j.energy.2005.06.002