The DOI matches its Crossref record; 70 of the 71 references it cites were found in a registry or an index.
Experimental study of the influence of thermal mass on thermal comfort and cooling energy demand in residential buildings
Open accessAbstract
The article presents the results of experimental research carried out in two real-scale detached energy-efficient single-family buildings designed to be almost identical with exempt to the construction of their external and internal walls; lightweight skeletal versus traditional masonry construction. The reduction of the average indoor temperature during the heatwave of August 2015 obtained by increasing the thermal mass of the building was 2.8 ± 0.34 °C, with the maximum value at the hottest part of the day being 3.4 °C. Replacing the lightweight frame structure of the walls with cellular concrete, in an exceptionally warm August, with an average outside temperature of 22.5 °C, shortened the total time of occurrence of indoor temperature higher than 28 °C from 18.6 days to only 8 h. The cooling effect of building thermal mass remained stable during all 14 days of heat wave with only slight diurnal variations. The total reduction in the cooling energy demand achieved was 67% at 25 °C set point temperature and 75% at set point temperature 26 °C respectively.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In their analysis, the use of concrete ground floors and walls in a detached single-family house, combined with nighttime ventilation and shading devices, substantially reduces the risk of overheating and the need for the installation of active cooling systems.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [166]
Citations
Cites
World map of the Köppen-Geiger climate classification updated
Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006) · Meteorologische Zeitschrift · doi:10.1127/0941-2948/2006/0130 · Cited by 11,456
Top ten European heatwaves since 1950 and their occurrence in the coming decades
Russo, S., Sillmann, J., & Fischer, E. M. (2015) · Environmental Research Letters · doi:10.1088/1748-9326/10/12/124003 · Cited by 817
Cooling the buildings – past, present and future
Santamouris, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.07.034 · Cited by 565
Energy flexibility of residential buildings using short term heat storage in the thermal mass
Dréau, J. L., & Heiselberg, P. (2016) · Energy · doi:10.1016/j.energy.2016.05.076 · Cited by 453
Passive cooling dissipation techniques for buildings and other structures: The state of the art
Santamouris, M., & Kolokotsa, D. D. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.11.002 · Cited by 447
Investigation of the thermal performance of a passive solar test-room with wall latent heat storage
Athienitis, A. K., Liu, C., Hawes, D. W., Banu, D., & Feldman, D. G. (1997) · Building and Environment · doi:10.1016/s0360-1323(97)00009-7 · Cited by 438
Experimental assessment of a phase change material for wall building use
Kuznik, F., & Virgone, J. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.01.004 · Cited by 436
Thermal inertia in buildings: A review of impacts across climate and building use
Verbeke, S., & Audenaert, A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.083 · Cited by 419
Li, D. H. W., Yang, L., & Lam, J. C. (2012) · Energy · doi:10.1016/j.energy.2012.03.044 · Cited by 385
Energetic efficiency of room wall containing PCM wallboard: A full-scale experimental investigation
Kuznik, F., Virgone, J., & Roux, J.-J. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.01.022 · Cited by 322
Cited by
Sorted by citations
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Wang, P., Liu, Z., & Zhang, L. (2021) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.103035 · Cited by 170
Envelope design for low-energy buildings in the tropics: A review
Gupta, V., & Deb, C. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113650 · Cited by 129
The impact of thermal mass and insulation of building structure on energy efficiency
Zilberberg, E., Trapper, P. A., Meir, I. A., & Isaac, S. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110954 · Cited by 89
Kuczyński, T., Staszczuk, A. K., Gortych, M., & Stryjski, R. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108126 · Cited by 100
Self-citation
Metadata
- Authors
- Kuczyński, T., & Staszczuk, A.
- Affiliations
- University of Zielona Góra (PL)
- Corresponding author
- Staszczuk, A.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 195
- Pages
- 116984
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W3000321042
- Cited by
- 131
- References
- 71
- Citations by year
- 2026: 21 · 2025: 20 · 2024: 18 · 2023: 27 · 2022: 19 · 2021: 19 · 2020: 7
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Energy (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
- Keywords
- building thermal mass, thermal comfort, cooling demand, residential buildings, foam concrete, masonry walls, heat waves, indoor temperature, setpoint temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review