The DOI matches its Crossref record; 70 of the 71 references it cites were found in a registry or an index.
Experimental study of the influence of thermal mass on thermal comfort and cooling energy demand in residential buildings
Open accessAbstract
The article presents the results of experimental research carried out in two real-scale detached energy-efficient single-family buildings designed to be almost identical with exempt to the construction of their external and internal walls; lightweight skeletal versus traditional masonry construction. The reduction of the average indoor temperature during the heatwave of August 2015 obtained by increasing the thermal mass of the building was 2.8 ± 0.34 °C, with the maximum value at the hottest part of the day being 3.4 °C. Replacing the lightweight frame structure of the walls with cellular concrete, in an exceptionally warm August, with an average outside temperature of 22.5 °C, shortened the total time of occurrence of indoor temperature higher than 28 °C from 18.6 days to only 8 h. The cooling effect of building thermal mass remained stable during all 14 days of heat wave with only slight diurnal variations. The total reduction in the cooling energy demand achieved was 67% at 25 °C set point temperature and 75% at set point temperature 26 °C respectively.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In their analysis, the use of concrete ground floors and walls in a detached single-family house, combined with nighttime ventilation and shading devices, substantially reduces the risk of overheating and the need for the installation of active cooling systems.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [166]
Citations
Cites
World map of the Köppen-Geiger climate classification updated
Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006) · Meteorologische Zeitschrift · doi:10.1127/0941-2948/2006/0130 · Cited by 11,456
Top ten European heatwaves since 1950 and their occurrence in the coming decades
Russo, S., Sillmann, J., & Fischer, E. M. (2015) · Environmental Research Letters · doi:10.1088/1748-9326/10/12/124003 · Cited by 817
Cooling the buildings – past, present and future
Santamouris, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.07.034 · Cited by 565
Energy flexibility of residential buildings using short term heat storage in the thermal mass
Dréau, J. L., & Heiselberg, P. (2016) · Energy · doi:10.1016/j.energy.2016.05.076 · Cited by 453
Passive cooling dissipation techniques for buildings and other structures: The state of the art
Santamouris, M., & Kolokotsa, D. D. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.11.002 · Cited by 447
Investigation of the thermal performance of a passive solar test-room with wall latent heat storage
Athienitis, A. K., Liu, C., Hawes, D. W., Banu, D., & Feldman, D. G. (1997) · Building and Environment · doi:10.1016/s0360-1323(97)00009-7 · Cited by 438
Experimental assessment of a phase change material for wall building use
Kuznik, F., & Virgone, J. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.01.004 · Cited by 436
Thermal inertia in buildings: A review of impacts across climate and building use
Verbeke, S., & Audenaert, A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.083 · Cited by 419
Li, D. H. W., Yang, L., & Lam, J. C. (2012) · Energy · doi:10.1016/j.energy.2012.03.044 · Cited by 385
Energetic efficiency of room wall containing PCM wallboard: A full-scale experimental investigation
Kuznik, F., Virgone, J., & Roux, J.-J. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.01.022 · Cited by 322
Energy-efficient envelope design for high-rise apartments
Cheung, C. K., Fuller, R. J., & Luther, M. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.05.002 · Cited by 292
The impact of climate change on the overheating risk in dwellings—A Dutch case study
Hamdy, M., Carlucci, S., Hoes, P.-J., & Hensen, J. L. M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.031 · Cited by 286
Evola, G., Marletta, L., & Sicurella, F. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.09.021 · Cited by 281
Passive design optimization of low energy buildings in different climates
Harkouss, F., Fardoun, F., & Biwolé, P. H. (2018) · Energy · doi:10.1016/j.energy.2018.09.019 · Cited by 270
The impact of thermal mass on building energy consumption
Reilly, A., & Kinnane, O. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.04.024 · Cited by 268
Al-Sanea, S. A., Zedan, M. F., & Al-Hussain, S. N. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.08.009 · Cited by 262
Kuznik, F., & Virgone, J. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.11.022 · Cited by 254
Thermal mass and night ventilation as passive cooling design strategy
Shaviv, E., Yezioro, A., & Capeluto, I. G. (2001) · Renewable Energy · doi:10.1016/s0960-1481(01)00027-1 · Cited by 248
Influence of insulation configuration on heating and cooling loads in a continuously used building
Kossecka, E., & Kośny, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(01)00121-9 · Cited by 248
An investigation into future performance and overheating risks in Passivhaus dwellings
McLeod, R. S., Hopfe, C. J., & Kwan, A. S. K. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.024 · Cited by 242
Wind power integration using individual heat pumps – Analysis of different heat storage options
Hedegaard, K., Mathiesen, B. V., Lund, H., & Heiselberg, P. (2012) · Energy · doi:10.1016/j.energy.2012.09.030 · Cited by 237
Recent progress on passive cooling techniques
Santamouris, M., Pavlou, K., Synnefa, A., Niachou, K., & Kolokotsa, D. D. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.008 · Cited by 236
Potential of structural thermal mass for demand-side management in dwellings
Reynders, G., Nuytten, T., & Saelens, D. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.03.010 · Cited by 227
A state of art review on the district heating systems
Mazhar, A. R., Liu, S., & Shukla, A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.08.005 · Cited by 202
Cooling load reduction by using thermal mass and night ventilation
Yang, L., & Li, Y. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.05.014 · Cited by 186
Romanchenko, D., Kensby, J., Odenberger, M., & Johnsson, F. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.01.068 · Cited by 181
Economic impact of integrating PCM as passive system in buildings using Fanger comfort model
Saffari, M., de Gracia, Á., Ushak, S., & Cabeza, L. F. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.12.006 · Cited by 179
Gregory, K., Moghtaderi, B., Sugo, H., & Page, A. W. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.04.001 · Cited by 178
Johra, H., Heiselberg, P., & Dréau, J. L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.012 · Cited by 178
Berardi, U., & Soudian, S. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.12.016 · Cited by 174
Zhu, L., Hurt, R., Correia, D., & Boehm, R. F. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.10.003 · Cited by 170
Givoni, B. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00056-x · Cited by 166
Sage-Lauck, J. S., & Sailor, D. J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.04.028 · Cited by 166
Overheating investigation in UK social housing flats built to the Passivhaus standard
Sameni, S. M. T., Gaterell, M. R., Montazami, A., & Ahmed, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.030 · Cited by 159
Jamil, H., Alam, M., Sanjayan, J., & Wilson, J. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.09.064 · Cited by 136
Bojic, M. L., Yik, F. W. H., & Sat, P. S. K. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00125-0 · Cited by 134
Masy, G., Georges, E., Verhelst, C., Lemort, V., & André, P. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1035590 · Cited by 132
van Hooff, T., Blocken, B. J. E., Timmermans, H. J. P., & Hensen, J. J. (2015) · Energy · doi:10.1016/j.energy.2015.11.036 · Cited by 131
Investigating the potential of overheating in UK dwellings as a consequence of extant climate change
Peacock, A., Jenkins, D. P., & Kane, D. (2010) · Energy Policy · doi:10.1016/j.enpol.2010.01.021 · Cited by 123
Martín, S., Mazarrón, F. R., & Guerrero, I. C. (2009) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2009.11.002 · Cited by 118
Monitoring summer indoor overheating in the London housing stock
Pathan, A., Mavrogianni, A., Summerfield, A. J., Oreszczyn, T., & Davies, M. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.049 · Cited by 116
Economic optimization of PCM and insulation layer thickness in residential buildings
Baniassadi, A., Sajadi, B., Amidpour, M., & Noori, N. (2016) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2016.01.008 · Cited by 114
Thermal inertia and energy efficiency – Parametric simulation assessment on a calibrated case study
Aste, N., Leonforte, F., Manfren, M., & Mazzon, M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.084 · Cited by 104
Evola, G., Marletta, L., & Sicurella, F. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.11.089 · Cited by 103
Heracleous, C., & Michael, A. (2018) · Energy · doi:10.1016/j.energy.2018.10.051 · Cited by 94
Albayyaa, H., Hagare, D., & Saha, S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.09.036 · Cited by 94
Annual energy analysis of concrete containing phase change materials for building envelopes
Thiele, A. M., Jamet, A., Sant, G., & Pilon, L. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.06.068 · Cited by 83
Heat waves in Poland in the period 1951-2015: trends, patterns and driving factors
Wibig, J. (2017) · Meteorology Hydrology and Water Management · doi:10.26491/mhwm/78420 · Cited by 78
Kalema, T., Jóhannesson, G. A., Pylsy, P., & Hagengran, P. (2008) · Journal of Building Physics · doi:10.1177/1744259108093920 · Cited by 78
Taylor, J., Wilkinson, P., Picetti, R., Symonds, P., Heaviside, C., Macintyre, H. L., Davies, M., Mavrogianni, A., & Hutchinson, E. J. (2017) · Environment International · doi:10.1016/j.envint.2017.11.005 · Cited by 76
Strong heat and cold waves in Poland in relation with the large-scale atmospheric circulation
Tomczyk, A. M., Bednorz, E., Półrolniczak, M., & Kolendowicz, L. (2018) · Theoretical and Applied Climatology · doi:10.1007/s00704-018-2715-y · Cited by 71
The growing threat of heat disasters
Sailor, D. J., Baniassadi, A., O’Lenick, C. R., & Wilhelmi, O. V. (2019) · Environmental Research Letters · doi:10.1088/1748-9326/ab0bb9 · Cited by 70
Brambilla, A., & Jusselme, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.070 · Cited by 65
Passive survivability of buildings under changing urban climates across eight US cities
Baniassadi, A., Sailor, D. J., Krayenhoff, E. S., Broadbent, A. M., & Georgescu, M. (2019) · Environmental Research Letters · doi:10.1088/1748-9326/ab28ba · Cited by 62
High resolution mapping of overheating and mortality risk
Liu, C., Kershaw, T., Fosas, D., Gonzalez, A. P. R., Natarajan, S., & Coley, D. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.028 · Cited by 50
The August 2015 mega‐heatwave in Poland in the context of past events
Krzyżewska, A., & Dyer, J. L. (2018) · Weather · doi:10.1002/wea.3244 · Cited by 49
Salthammer, T., Schieweck, A., Gu, J., Ameri, S., & Uhde, E. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.07.050 · Cited by 49
2018 summer extreme temperatures in South Korea and their intensification under 3 °C global warming
Im, E., Xuan, T. N., Kim, Y., & Ahn, J. (2019) · Environmental Research Letters · doi:10.1088/1748-9326/ab3b8f · Cited by 49
The optimisation of intermittent heating
Bloomfield, D. P., & Fisk, D. (1977) · Building and Environment · doi:10.1016/0360-1323(77)90006-3 · Cited by 44
Coldwavesin Poland – frequency, trends and relationships with atmospheric circulation
Wibig, J., Podstawczyńska, A., Rzepa, M., & Piotrowski, P. (2009) · Geographia Polonica · doi:10.7163/gpol.2009.1.4 · Cited by 42
Dominković, D. F., Wahlroos, M., Syri, S. M., & Pedersen, A. S. (2018) · Energy · doi:10.1016/j.energy.2018.04.028 · Cited by 39
Kalz, D. E., Wienold, J., Fischer, M., & Calı̀, D. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.06.002 · Cited by 37
Setting Housing Standards to Improve Global Health
Howden-Chapman, P., Roebbel, N., & Chisholm, E. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14121542 · Cited by 33
Mantesi, E., Hopfe, C. J., Mourkos, K., Glass, J., & Cook, M. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.02.021 · Cited by 31
Heatwavesin Poland – frequency, trends and relationships with atmospheric circulation
Wibig, J., Podstawczyńska, A., Rzepa, M., & Piotrowski, P. (2009) · Geographia Polonica · doi:10.7163/gpol.2009.1.3 · Cited by 28
Siddiqui, O., Kumar, R., Fung, A. S., Zhang, D., White, M. A., & Whitman, C. A. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.05.021 · Cited by 24
Brambilla, A., Bonvin, J., Flourentzou, F., & Jusselme, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.12.010 · Cited by 21
Staszczuk, A. K., Wojciech, M., & Kuczyński, T. (2017) · Energy · doi:10.1016/j.energy.2017.07.060 · Cited by 16
Self-citationAir conditioning energy use in houses in Southern England
He, J. Y., Young, A., Pathan, A., & Oreszczyn, T. (2005) · UCL Discovery (University College London) · Cited by 13
Thermal Performance of Buildings with Heavy Walls
Bellamy, L., & Mackenzie, D. W. R. (2001) · Cited by 9
Cited by
Sorted by citations
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Wang, P., Liu, Z., & Zhang, L. (2021) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.103035 · Cited by 170
Envelope design for low-energy buildings in the tropics: A review
Gupta, V., & Deb, C. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113650 · Cited by 129
The impact of thermal mass and insulation of building structure on energy efficiency
Zilberberg, E., Trapper, P. A., Meir, I. A., & Isaac, S. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110954 · Cited by 89
Kuczyński, T., Staszczuk, A. K., Gortych, M., & Stryjski, R. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108126 · Cited by 100
Self-citation
Metadata
- Authors
- Kuczyński, T., & Staszczuk, A.
- Affiliations
- University of Zielona Góra (PL)
- Corresponding author
- Staszczuk, A.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 195
- Pages
- 116984
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W3000321042
- Cited by
- 131
- References
- 71
- Citations by year
- 2026: 21 · 2025: 20 · 2024: 18 · 2023: 27 · 2022: 19 · 2021: 19 · 2020: 7
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Energy (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
- Keywords
- building thermal mass, thermal comfort, cooling demand, residential buildings, foam concrete, masonry walls, heat waves, indoor temperature, setpoint temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review