CoChat

Low-cost sensors as an alternative for long-term air quality monitoring

Open access
Liu, Xiaoting, Jayaratne, Rohan, Thai, Phong, Kuhn, Tara, Zing, Isak, Christensen, Bryce, Lamont, Riki, Dunbabin, Matthew, Zhu, Sicong, Gao, Jian, Wainwright, David, Neale, Donald, Kan, Ruby, Kirkwood, John, Morawska, Lidia · 2020 · Environmental Research
Cited by 222

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

Low-cost air quality sensors are increasingly being used in many applications; however, many of their performance characteristics have not been adequately investigated. This study was conducted over a period of 13 months using low-cost air quality monitors, each comprising two low-cost sensors, which were subjected to a wide range of pollution sources and concentrations, relative humidity and temperature at four locations in Australia and China. The aim of the study was to establish the performance characteristics of the two low-cost sensors (a Plantower PMS1003 for PM2.5 and an Alphasense CO-B4 for carbon monoxide, CO) and the KOALA monitor as a whole under various conditions. Parameters evaluated included the inter-variability between individual monitors, the accuracy of monitors in comparison with the reference instruments, the effect of temperature and RH on the performance of the monitors, the responses of the PM2.5 sensors to different types of aerosols, and the long-term stability of the PM2.5 and CO sensors. The monitors showed high inter-correlations (r > 0.91) for both PM2.5 and CO measurements. The monitor performance varied with location, with moderate to good correlations with reference instruments for PM2.5 (0.44< R2 < 0.91) and CO (0.37< R2 < 0.90). The monitors performed well at relative humidity < 75% and high temperature conditions; however, two monitors in Beijing failed at low temperatures, probably due to electronic board failure. The PM2.5 sensor was less sensitive to marine aerosols and fresh vehicle emissions than to mixed urban background emissions, aged traffic emissions and industrial emissions. The long-term stability of the PM2.5 and CO sensors was good, while CO relative errors were affected by both high and low temperatures. Overall, the KOALA monitors performed well in the environments in which they were operated and provided a valuable contribution to long-term air quality monitoring within the elucidated limitations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.envres.2020.109438

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

Metadata

Authors
Liu, X., Jayaratne, R., Thai, P., Kuhn, T., Zing, I., Christensen, B., Lamont, R., Dunbabin, M., Zhu, S., Gao, J., Wainwright, D., Neale, D., Kan, R., Kirkwood, J., & Morawska, L.
Venue
Environmental Research
Publisher
Elsevier BV
Published
2020-06
Volume
185
Pages
109438
ISSN
0013-9351 (ISSN-L)
OpenAlex
W3015082165
Cited by
222
References
31
FWCI
10.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.