Thermal management analysis using heat pipe in the high current discharging of lithium-ion battery in electric vehicles

Open access
Behi, Hamidreza, Karimi, Danial, Behi, Mohammadreza, Jaguemont, Joris, Ghanbarpour, Morteza, Behnia, Masud, Berecibar, Maitane, Van Mierlo, Joeri · 2020 · Journal of Energy Storage

Abstract

Thermal management system (TMS) for commonly used lithium-ion (Li-ion) batteries is an essential requirement in electric vehicle operation due to the excessive heat generation of these batteries during fast charging/discharging. In the current study, a thermal model of lithium-titanate (LTO) cell and three cooling strategies comprising natural air cooling, forced fluid cooling, and a flat heat pipe-assisted method is proposed experimentally. A new thermal analysis of the single battery cell is conducted to identify the most critical zone of the cell in terms of heat generation. This analysis allowed us to maximize heat dissipation with only one heat pipe mounted on the vital region. For further evaluation of the proposed strategies, a computational fluid dynamic (CFD) model is built in COMSOL Multiphysics® and validated with surface temperature profile along the heat pipe and cell. For real applications, a numerical optimization computation is also conducted in the module level to investigate the cooling capacity of the liquid cooling system and liquid cooling system embedded heat pipe (LCHP). The results show that the single heat pipe provided up to 29.1% of the required cooling load in the 8C discharging rate. Moreover, in the module level, the liquid cooling system and LCHP show better performance compared with natural air cooling while reducing the module temperature by 29.9% and 32.6%, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.est.2020.101893

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 204

Metadata

Authors
Behi, H., Karimi, D., Behi, M., Jaguemont, J., Ghanbarpour, M., Behnia, M., Berecibar, M., & Van Mierlo, J.
Venue
Journal of Energy Storage
Publisher
Elsevier BV
Published
2020-12
Volume
32
Pages
101893
ISSN
2352-152X (ISSN-L)
OpenAlex
W3089040464
Cited by
204
References
3
FWCI
10.28
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermal management analysis using heat pipe in the high current discharging of lithium-ion battery in electric vehicles. https://app.cochat.ai/papers/10.1016/j.est.2020.101893
The paper
Behi, H., Karimi, D., Behi, M., Jaguemont, J., Ghanbarpour, M., Behnia, M., Berecibar, M., & Van Mierlo, J. (2020). Thermal management analysis using heat pipe in the high current discharging of lithium-ion battery in electric vehicles. Journal of Energy Storage. https://doi.org/10.1016/j.est.2020.101893

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.