Energy and entropy-based feature extraction for locating fault on transmission lines by using neural network and wavelet packet decomposition
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The aim of this paper is to estimate the fault location on transmission lines quickly and accurately. The faulty current and voltage signals obtained from a simulation are decomposed by wavelet packet transform (WPT). The extracted features are applied to artificial neural network (ANN) for estimating fault location. As data sets increase in size, their analysis become more complicated and time consuming. The energy and entropy criterion are applied to wavelet packet coefficients to decrease the size of feature vectors. The test results of ANN demonstrate that the applying of energy criterion to current signals after WPT is a very powerful and reliable method for reducing data sets in size and hence estimating fault locations on transmission lines quickly and accurately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Entropy-based algorithms for best basis selection
Coifman, R. R., & Wickerhauser, M. V. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119732 · Cited by 3,188 · cited 1×
“There are more different entropy types such as Shannon, log energy, sure, threshold, etc. (Coifman & Wickerhauser, 1992).”
BackgroundNeural Network Toolbox™ User's Guide
Beale, M. H., Hagan, M., & Demuth, H. B. (2015) · Cited by 1,690
A Wavelet Packet Approach to Transient Signal Classification
Learned, R. E., & Willsky, A. S. (1995) · Applied and Computational Harmonic Analysis · doi:10.1006/acha.1995.1019 · Cited by 148 · cited 1×
“The top level of the WPT is the time representation of the signal, whereas, the bottom level has better frequency resolution (Learned & Willsky, 1995).”
BackgroundA new accurate fault locating algorithm for series compensated lines
Saha, M. M., Iżykowski, J., Rosołowski, E., et al. (1999) · IEEE Transactions on Power Delivery · doi:10.1109/61.772316 · Cited by 131
A wavelet packet based sifting process and its application for structural health monitoring
Shinde, A., & Hou, Z. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1383970 · Cited by 25
A fault detection technique with preconditioned ANN in power systems
Mori, H., Aoyama, H., Yamanaka, T., et al. (2003) · IEEE PES Transmission and Distribution Conference and Exhibition · doi:10.1109/tdc.2002.1177570 · Cited by 14
A fault locator for transmission lines based on Prony method
Tawfik, M. M., & Morcos, M. M. (2003) · IEEE Power Engineering Society Summer Meeting · doi:10.1109/pess.1999.787443 · Cited by 9 · cited 1×
“One of the other techniques employed is Fourier transform which obtain line impedance in the frequency domain (Tawfik & Morcos, 1998).”
Method
Cited by
Chen, K., Huang, C., & He, J. (2016) · High Voltage · doi:10.1049/hve.2016.0005 · Cited by 377
Wang, D., Miao, D., & Xie, C. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.05.096 · Cited by 268
Chen, K., Hu, J., & He, J. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2598881 · Cited by 176
Aftab, M. A., Hussain, S. M. S., Ali, I., & Ustun, T. S. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105410 · Cited by 169
Ali, Z., Terriche, Y., Hoang, L. Q. N., Abbas, S. Z., Hassan, M. A., Sadiq, M., Su, C.-L., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3112383 · Cited by 104
“ANN train the faulty signal as an input to determine the fault condition as an output [141].”
Background
Metadata
- Authors
- EKICI, S., YILDIRIM, S., & POYRAZ, M.
- Venue
- Expert Systems with Applications
- Publisher
- Elsevier BV
- Published
- 2008-05
- Volume
- 34
- Issue
- 4
- Pages
- 2937-2944
- ISSN
- 0957-4174 (ISSN-L)
- OpenAlex
- W2012222827
- Cited by
- 200
- References
- 7
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.