The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Real-time classification for autonomous drowsiness detection using eye aspect ratio
Abstract
Abstract Various automated systems require human supervision in complex environments: this can be a monotonous task but still requiring a significant degree of attention. If those tasks are decisive to the process and work safety, then it is imperative that operators maintain adequate levels of alertness to execute necessary actions. Here, we developed a methodology for drowsiness detection based on eye patterns of people monitored by video streams. In contrast to physically intrusive methods based on a biological approach (e.g. electrooculogram), computer vision and machine leaning (ML) were used to create a low-cost real-time system to detect whether a user (operator) is drowsy using a simple web camera. The proposed methodology employs drowsiness rules for blink patterns from neuroscience literature, which allows for automatic alertness supervision of users reducing risks of potential human error and then preventing accidents. Specifically, a temporal element is introduced by concatenating information from several consecutive video frames coupled with the ability of ML models in identifying different eye behavior. Here, multilayer perceptron, random forest, and support vector machines were analyzed: the latter had the overall best performance in terms of average test accuracy (94.9%) and required execution time. The proposed methodology also contains a personal feedback proposal to adapt models for each specific user providing even better results. We validated our model in DROZY – a public database for human drowsiness. Inter- and intra-subject investigations were conducted considering the Karolinska Sleepiness Scale (KSS) evaluation and the reaction time as performance indicators. In inter-subject analysis, our model did not provide any warning when a subject was awake, but an average of 16.1 warnings were emitted for drowsy subjects with 94.44% accuracy. For intra-subject analysis, our model could detect when subjects were prone to drowsiness. These are interesting and promising results regarding drowsiness detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Histograms of Oriented Gradients for Human Detection
Dalal, N., & Triggs, B. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.177 · Cited by 33,584
Robust Real-Time Face Detection
Viola, P., & Jones, M. J. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000013087.49260.fb · Cited by 14,097
Subjective and objective sleepiness in the active individual
Åkerstedt, T., & Gillberg, M. (1990) · International Journal of Neuroscience · doi:10.3109/00207459008994241 · Cited by 3,088
Variable selection using random forests
Genuer, R., Poggi, J.-M., & Tuleau-Malot, C. (2010) · Pattern Recognition Letters · doi:10.1016/j.patrec.2010.03.014 · Cited by 2,619
Robust object tracking with online multiple instance learning
Babenko, B., Yang, M.-H., & Belongie, S. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.226 · Cited by 2,007
Sleep Deprivation and Vigilant Attention
Lim, J., & Dinges, D. F. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1417.002 · Cited by 1,213
Blinks and saccades as indicators of fatigue in sleepiness warnings: looking tired?
Schleicher, R., Galley, N., Briest, S., & Galley, L. (2008) · Ergonomics · doi:10.1080/00140130701817062 · Cited by 476
Cited by
A Review of Recent Developments in Driver Drowsiness Detection Systems
Albadawi, Y., Takruri, M., & Awad, M. (2022) · Sensors · doi:10.3390/s22052069 · Cited by 255
Metadata
- Authors
- Maior, C. B. S., Moura, M. J. D. C., Santana, J. M. M., & Lins, I. D.
- Venue
- Expert Systems with Applications
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 158
- Pages
- 113505
- ISSN
- 0957-4174 (ISSN-L)
- OpenAlex
- W3022039961
- Cited by
- 176
- References
- 8
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time classification for autonomous drowsiness detection using eye aspect ratio. https://app.cochat.ai/papers/10.1016/j.eswa.2020.113505
- The paper
- Maior, C. B. S., Moura, M. J. D. C., Santana, J. M. M., & Lins, I. D. (2020). Real-time classification for autonomous drowsiness detection using eye aspect ratio. Expert Systems with Applications. https://doi.org/10.1016/j.eswa.2020.113505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.