Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Real-time classification for autonomous drowsiness detection using eye aspect ratio

Maior, Caio Bezerra Souto, Moura, Márcio José das Chagas, Santana, João Mateus Marques, Lins, Isis Didier · 2020 · Expert Systems with Applications

Abstract

Abstract Various automated systems require human supervision in complex environments: this can be a monotonous task but still requiring a significant degree of attention. If those tasks are decisive to the process and work safety, then it is imperative that operators maintain adequate levels of alertness to execute necessary actions. Here, we developed a methodology for drowsiness detection based on eye patterns of people monitored by video streams. In contrast to physically intrusive methods based on a biological approach (e.g. electrooculogram), computer vision and machine leaning (ML) were used to create a low-cost real-time system to detect whether a user (operator) is drowsy using a simple web camera. The proposed methodology employs drowsiness rules for blink patterns from neuroscience literature, which allows for automatic alertness supervision of users reducing risks of potential human error and then preventing accidents. Specifically, a temporal element is introduced by concatenating information from several consecutive video frames coupled with the ability of ML models in identifying different eye behavior. Here, multilayer perceptron, random forest, and support vector machines were analyzed: the latter had the overall best performance in terms of average test accuracy (94.9%) and required execution time. The proposed methodology also contains a personal feedback proposal to adapt models for each specific user providing even better results. We validated our model in DROZY – a public database for human drowsiness. Inter- and intra-subject investigations were conducted considering the Karolinska Sleepiness Scale (KSS) evaluation and the reaction time as performance indicators. In inter-subject analysis, our model did not provide any warning when a subject was awake, but an average of 16.1 warnings were emitted for drowsy subjects with 94.44% accuracy. For intra-subject analysis, our model could detect when subjects were prone to drowsiness. These are interesting and promising results regarding drowsiness detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eswa.2020.113505

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 176

Metadata

Authors
Maior, C. B. S., Moura, M. J. D. C., Santana, J. M. M., & Lins, I. D.
Venue
Expert Systems with Applications
Publisher
Elsevier BV
Published
2020-11
Volume
158
Pages
113505
ISSN
0957-4174 (ISSN-L)
OpenAlex
W3022039961
Cited by
176
References
8
FWCI
21.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time classification for autonomous drowsiness detection using eye aspect ratio. https://app.cochat.ai/papers/10.1016/j.eswa.2020.113505
The paper
Maior, C. B. S., Moura, M. J. D. C., Santana, J. M. M., & Lins, I. D. (2020). Real-time classification for autonomous drowsiness detection using eye aspect ratio. Expert Systems with Applications. https://doi.org/10.1016/j.eswa.2020.113505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.