Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
AIMS: Radionuclide techniques, and recently MRI, have been used for clinical evaluation of right ventricular (RV) volumes function (RVEF) and volumes; but with the introduction of 3D echocardiography, new echocardiographic possibilities for RV evaluation independent of geometrical assumptions have emerged. This study compared classic and new echocardiographic and radionuclide estimates, including gated blood pool single-photon emission computed tomography (SPECT) of RV size and function to RV volumes, and ejection fraction (RVEF) measured by magnetic resonance imaging (MRI). METHODS AND RESULTS: Thirty-four subjects with (a) prior inferior ST-elevation myocardial infarction (n=17), (b) a history of pulmonary embolism and persistent dyspnea (n=7) or (c) normal subjects (n=10) had 2D and 3D echocardiography, SPECT and MRI within 24h. End-diastolic volume and peak tricuspid regurgitation velocity were increased in patients with a history of pulmonary embolism compared to healthy subjects, 130+/-26 ml vs. 94+/-26 ml, P<0.05, and 3.3+/-1.1m/s vs. 2.3+/-0.3m/s, P<0.05, respectively, whereas no differences in RVEF were seen in the three groups. Echocardiographic as well as SPECT estimates of RV volume showed significant correlation to RV volumes by MRI. Tricuspid annular plane systolic excursion (TAPSE) had the better correlation to RVEF by MRI, r=0.48, P<0.01; whereas 3D echocardiography had a correlation of 0.42, P<0.05. Compared to MRI, 3D echocardiography underestimated RVEF by 5.9%, 95% limits of agreement 1.6-10.2%. CONCLUSION: 3D echocardiographic estimates of RV size and RVEF show only moderate correlation to MRI measures of these parameters, and simple 2D echocardiographic estimates of RV size and function show similar correlations. For routine clinical purposes the simple TAPSE may be preferred over 3D and SPECT techniques for RVEF estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography
Schiller, N. B., Shah, P. M., Crawford, M., DeMaria, A., Devereux, R., Feigenbaum, H., Gutgesell, H., Reichek, N., Sahn, D., Schnittger, I., et al. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80014-8 · Cited by 8,121
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · cited 2×
“96 SD as proposed by Bland and Altman.(13) For RVEF, values are calculated as percentage and the SEE and absolute differences are given in percentage points.”
MethodInfluentialGrothues, F., Smith, G. C., Moon, J. C. C., Bellenger, N. G., Collins, P., Klein, H. U., & Pennell, D. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02381-0 · Cited by 1,267
Assessment of right ventricular function using two-dimensional echocardiography
Kaul, S., Tei, C., Hopkins, J. M., & Shah, P. M. (1984) · American Heart Journal · doi:10.1016/0002-8703(84)90095-4 · Cited by 1,037
Grothues, F., Moon, J. C., Bellenger, N. G., Smith, G. S., Klein, H. U., & Pennell, D. J. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.005 · Cited by 776
Meluzín, J. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2296 · Cited by 641
Ghio, S., Recusani, F., Klersy, C., Sebastiani, R., Laudisa, M. L., Campana, C., Gavazzi, A., & Tavazzi, L. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00877-2 · Cited by 513
Vogel, M., Schmidt, M. R., Kristiansen, S. B., Cheung, M., White, P. A., Sorensen, K., & Redington, A. N. (2002) · Circulation · doi:10.1161/01.cir.0000013773.67850.ba · Cited by 443
Malm, S., Frigstad, S., Sagberg, E., Larsson, H., & Skjaerpe, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.068 · Cited by 323
Three-dimensional echocardiography. In vivo validation for left ventricular volume and function.
Siu, S. C., Rivera, J. M., Guerrero, J. L., Handschumacher, M. D., Lethor, J. P., Weyman, A. E., Levine, R. A., & Picard, M. H. (1993) · Circulation · doi:10.1161/01.cir.88.4.1715 · Cited by 245
Reproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass
Pattynama, P. M. T., Lamb, H. J., Van der Velde, E. A., Van der Geest, R. J., Van der Wall, E. E., & De Roos, A. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00076-f · Cited by 193
Vogel, M., Gutberlet, M., Dittrich, S., Hosten, N., & Lange, P. (1997) · Heart · doi:10.1136/hrt.78.2.127 · Cited by 157
Sievers, B., Kirchberg, S., Bakan, A., Franken, U., & Trappe, H. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120027800 · Cited by 142
Qin, J. X., Jones, M., Shiota, T., Greenberg, N. L., Tsujino, H., Firstenberg, M. S., Gupta, P. C., Zetts, A. D., Xu, Y., Sun, J., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00793-2 · Cited by 140
Three-dimensional echocardiography. In vivo validation for right ventricular volume and function.
Jiang, L., Siu, S. C., Handschumacher, M. D., Guererro, J. L., de Prada, J. A. V., King, M. E., Picard, M. H., Weyman, A. E., & Levine, R. A. (1994) · Circulation · doi:10.1161/01.cir.89.5.2342 · Cited by 127
Beygui, F., Furber, A., Del�pine, S., Helft, G., Metzger, J. P., Geslin, P., & Jeune, J. J. L. (2004) · International journal of cardiac imaging · doi:10.1007/s10554-004-1097-7 · Cited by 109
Papavassiliou, D. P., Parks, W. J., Hopkins, K. L., & Fyfe, D. A. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70051-3 · Cited by 100
Schenk, P. (2000) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(99)00121-7 · Cited by 99
Grothues, F., Smith, G. C., & Moon, J. (2002) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)00927-3 · Cited by 79
Pini, R., Giannazzo, G., Bari, M. D., Innocenti, F., Rega, L., Casolo, G., & Devereux, R. B. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70212-6 · Cited by 70
Fujimoto, S., Mizuno, R., Nakagawa, Y., Dohi, K., & Nakano, H. (1998) · International journal of cardiac imaging · doi:10.1023/a:1006117321095 · Cited by 53
MR Gradient Echo Volumetric Analysis of Human Cardiac Casts
Jauhiainen, T., Järvinen, V. M., Hekali, P. E., Poutanen, V.-P., Penttilä, A., & Kupari, M. M. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199811000-00012 · Cited by 53
Evaluation of methods for MR imaging of human right ventricular heart volumes and mass
Jauhiainen, T., Järvinen, V. M., & Hekali, P. E. (2002) · Acta Radiologica · doi:10.1034/j.1600-0455.2002.430609.x · Cited by 47
Right ventricular function: the comeback of echocardiography?
Helbing, W. A. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2003.12.001 · Cited by 32
Qin, J. X. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0016 · Cited by 25
Cited by
Haddad, F., Hunt, S. A., Rosenthal, D. N., & Murphy, D. J. (2008) · Circulation · doi:10.1161/circulationaha.107.653576 · Cited by 1,523
EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
Lang, R. M., Badano, L. P., Tsang, W., Adams, D. H., Agricola, E., Buck, T., Faletra, F. F., Franke, A., Hung, J., Pérez de Isla, L., et al. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.11.010 · Cited by 1,129
van Wolferen, S. A., Marcus, J. T., Boonstra, A., Marques, K. M. J., Bronzwaer, J. G. F., Spreeuwenberg, M. D., Postmus, P. E., & Vonk-Noordegraaf, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl477 · Cited by 753
EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
Lang, R. M., Badano, L. P., Tsang, W., Adams, D. H., Agricola, E., Buck, T., Faletra, F. F., Franke, A., Hung, J., de Isla, L. P., et al. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jer316 · Cited by 600
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Metadata
- Authors
- KJAERGAARD, J., PETERSEN, C., KJAER, A., SCHAADT, B., OH, J., & HASSAGER, C.
- Venue
- European Journal of Echocardiography
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-12
- Volume
- 7
- Issue
- 6
- Pages
- 430-438
- ISSN
- 1525-2167 (ISSN-L)
- OpenAlex
- W2115967240
- Cited by
- 288
- References
- 26
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.