CoChat

Closed loop stimulation in prevention of vasovagal syncope. Inotropy controlled pacing in vasovagal syncope (INVASY): a multicentre randomized, single blind, controlled study

Open access
OCCHETTA, E, BORTNIK, M, AUDOGLIO, R, VASSANELLI, C · 2004 · Europace
Cited by 117

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To determine whether dual-chamber rate-adaptive Closed Loop Stimulation (CLS) could prevent recurrence of Vasovagal Syncope (VVS). BACKGROUND: During VVS, an increase in myocardial contractility associated with a reduction of ventricular filling produces an increase in baroreceptor afferent flow and a consequent decrease in the heart rate. The CLS algorithm is a form of rate-adaptive pacing, which responds to myocardial contraction dynamics, by measuring variations in right ventricular intracardiac impedance: during an incipient VVS it could increase paced heart rate and avoid bradycardia, arterial hypotension and syncope. METHODS: Fifty patients (27 males, mean age 59+/-18 year) with severe and recurrent vasovagal syncope and positive Head Up Tilt Test (HUTT) with cardioinhibition, received a CLS pacemaker (INOS2, Biotronik GmbH Co., Germany). The primary end point was recurrence of two VVSs during a minimum of 1 year of follow-up. Randomization between DDD-CLS and DDI mode (40 bpm) pacing was performed only during the first stage of the study (first year): 9/26 randomized to DDI mode (control group) and 17/26 in DDD-CLS mode. All the 24 patients recruited in the second stage of the study (second year) were programmed in DDD-CLS mode. RESULTS: Of the nine patients randomized to the DDI mode, seven had recurrences of syncope during the first year. At the end of the first year the nine patients were reprogrammed to the CLS mode and no syncope occurred after reprogramming. The 41 patients programmed to CLS had a mean follow-up of 19+/-4 months: none reported VVS, only four (10%) reported occasional presyncope and their quality of life greatly improved. Positive HUTT at the end of the first year failed to predict the clinical response to CLS pacing. CONCLUSIONS: The study demonstrates the effectiveness of CLS pacing in preventing cardioinhibitory VVS. A possible placebo effect of pacemaker implantation occurred in 22% of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eupc.2004.08.009

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 117

Metadata

Authors
OCCHETTA, E., BORTNIK, M., AUDOGLIO, R., & VASSANELLI, C.
Venue
Europace
Published
2004-11
Volume
6
Issue
6
Pages
538-547
ISSN
1099-5129 (ISSN-L)
OpenAlex
W2156129433
Cited by
117
References
7
FWCI
3.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Closed loop stimulation in prevention of vasovagal syncope. Inotropy controlled pacing in vasovagal syncope (INVASY): a multicentre randomized, single blind, controlled study. https://app.cochat.ai/papers/10.1016/j.eupc.2004.08.009
The paper
OCCHETTA, E., BORTNIK, M., AUDOGLIO, R., & VASSANELLI, C. (2004). Closed loop stimulation in prevention of vasovagal syncope. Inotropy controlled pacing in vasovagal syncope (INVASY): a multicentre randomized, single blind, controlled study. Europace. https://doi.org/10.1016/j.eupc.2004.08.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.