Cited by 21Forensic Toxicology and Drug AnalysisBiosensors and Analytical DetectionHIV, Drug Use, Sexual Risk

Beyond fentanyl test strips: investigating other urine drug test strips for drug checking applications

Open access
Sisco, Edward, Appley, Meghan G., Pyfrom, Elise M., Banta-Green, Caleb J., Shover, Chelsea L., Molina, Caitlin A., Biamont, Ben, Robinson, Elizabeth L.·2024·Forensic Chemistry

Published version of a preprint

Abstract

Use of immunoassay test strips for the detection of fentanyl in drug samples has become commonplace in harm reduction, law enforcement, public health, customs, and forensic science settings for testing drug product. With the increase of xylazine in the drug supply in recent years, use of xylazine test strips has also increased. As use of test strips expands, a desire to implement them for other drugs may emerge. However, since these strips are designed for urine testing, it is important to understand their applicability to testing drug product. In this work, we investigate the utility of seven types of urine immunoassay test strips - amphetamine, benzodiazepine, cocaine, methamphetamine, nitazene, opiate, and xylazine - for drug checking applications. Reproducibility, sensitivity, cross-reactivity, and the effect of prolonged exposure to elevated temperatures were studied. Generally, the tests were found to be reproducible, able to detect trace (μg/mL) levels of the analyte of interest, and minimally affected by prolonged storage at elevated temperatures. Nearly all tests showed cross-reactivity with compounds other than the analyte of interest, highlighting the need to better understand these limitations prior to implementation in a drug checking scenario. The viability of expired cocaine, fentanyl, and methamphetamine test strips was also interrogated, and little to no change in sensitivity was found even though the tests were multiple years expired.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.forc.2024.100594

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • De Vrieze et al. examined the efficacy of the test strips using seized samples in Ghent, composed of either metonitazene, protonitazene, isotonitazene, butonitazene, or N-pyrrolidino etonitazene with an estimated purity of > 90%.

    “De Vrieze et al. [22] examined the efficacy of the test strips using seized samples in Ghent. These samples composed of either metonitazene, protonitazene, isotonitazene, butonitazene, or N-pyrrolidino etonitazene with an estimated purity of > 90%.”

    From Evaluation of nitazene immunoassay test strips for rapid in-situ detection of nitazene and nitazene analogs in illicit drug samples (2025) · cites this paper as [22]

    The Conclusions (page unavailable) explicitly state that this study did not investigate real-world samples or mixtures, contrary to the claim that it tested seized samples in Ghent. Materials & Methods describes prepared analyte solutions, and the paper provides no support for the claimed sample composition or >90% purity. (LLM, conf=0.90)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • In this study, no cross-reactivity was observed between the test strips and diamorphine, papaverine, acetylcodeine, 6-MAM, noscapine, caffeine, or paracetamol at 100,000 ng/mL.

    “This study, and previous studies such as Sisco et al. (2024) found no cross reactivity of the test strips with diamorphine, papaverine, acetylcodeine, 6-monoacetylmorphine (6-MAM), noscapine, caffeine or paracetamol at 100,000 ng/mL.”

    From Evaluation of nitazene immunoassay test strips for rapid in-situ detection of nitazene and nitazene analogs in illicit drug samples (2025) · cites this paper as Sisco et al. (2024)

    The Results and Discussion (Cross-Reactivity; page unavailable) report that opiate test strips gave positive results for 6-monoacetylmorphine, contrary to the claimed absence of cross-reactivity. Materials & Methods (Cross-Reactivity; page unavailable) also specifies testing at 10,000 and either 500,000 or 1,000,000 ng/mL, not 100,000 ng/mL. (LLM, conf=0.89)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • Immunoassays routinely used for conventional opioids are largely ineffective for most nitazenes due to their distinct chemical structures and insufficient cross-reactivity.

    “Immunoassays, routinely used for conventional opioids, are largely ineffective for most nitazenes due to their distinct chemical structures and insufficient cross-reactivity [47,48].”

    From Nitazenes: The Emergence of a Potent Synthetic Opioid Threat (2025) · cites this paper as [47]

    The Results and Discussion (Cross-Reactivity; page unavailable) report that opiate test strips detected several conventional opiates, while nitazene test strips detected all three nitazenes tested. The paper discusses structural similarity as a general factor in cross-reactivity, but does not establish that conventional-opioid immunoassays are ineffective for most nitazenes because of their distinct structures; its nitazene panel was limited to three compounds. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • The current study is the first to independently assess, in a laboratory context and using drug standards, the potential of the first commercially available BTNX Rapid ResponseTM NTS for drug checking purposes.

    “The current study is the first to independently assess, in a laboratory context and using drug standards, the potential of the first commercially available BTNX Rapid Response™ NTS for drug checking purposes.”

    From Nitazene test strips: a laboratory evaluation (2024) · cites this paper as [42]

    The Materials & Methods section describes laboratory testing of BTNX strips in solutions containing known analytes, and the Results and Discussion section reports testing nitazene strips against specific nitazenes for drug-checking applications. Our copy does not establish that the strips were the first commercially available BTNX Rapid Response™ NTS, or that this was the first independent assessment of them. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • The discrepancies between this study and De Vrieze et al. may be attributed to differences in sample preparation or potential variability between test strip batches.

    “These discrepancies may be attributed to differences in sample preparation or potential variability between test strip batches.”

    From Evaluation of nitazene immunoassay test strips for rapid in-situ detection of nitazene and nitazene analogs in illicit drug samples (2025) · cites this paper as [22]

    The Results and Discussion section reports that organic solvent used in sample preparation affected some test-strip results, supporting sample preparation as a possible source of differences. Our copy does not connect that effect to discrepancies with De Vrieze et al. or discuss variability between test-strip batches (searched: De Vrieze, batch variability). (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 25 · Cited by 21

Authors
Sisco, E., Appley, M. G., Pyfrom, E. M., Banta-Green, C. J., Shover, C. L., Molina, C. A., Biamont, B., & Robinson, E. L.
Affiliations
  • National Institute of Standards and Technology (US)
  • University of California, Los Angeles (US)
  • University of Washington (US)
Corresponding author
Sisco, Edward
Venue
Forensic Chemistry
Publisher
Elsevier BV
Published
2024-09
Volume
40
Pages
100594
ISSN
2468-1709 (ISSN-L)
OpenAlex
W4400109593
Cited by
21
References
25
Citations by year
2026: 6 · 2025: 14 · 2024: 1
FWCI
4.97
Type
journal article
Language
en
Open access
Locations
  • Forensic Chemistry (publishedVersion)
  • ChemRxiv (acceptedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Medicine › Epidemiology › HIV, Drug Use, Sexual Risk
Keywords
drug checking, fentanyl, xylazine, cocaine, methamphetamine, benzodiazepines, opiates, nitazenes, amphetamine, cross-reactivity, storage temperature effects

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review