The Amplex Red assay, a fluorescent assay for the detection of H2O2, relies on the reaction of H2O2 and colorless, nonfluorescent Amplex Red with a 1:1 stoichiometry to form colored, fluorescent resorufin, catalyzed by horseradish peroxidase (HRP). We have found that resorufin is artifactually formed when Amplex Red is exposed to light. In the absence of H2O2 and HRP, the absorption and fluorescence spectra of Amplex Red changed during exposure to ambient room light or instrumental excitation light, clearly indicating that the fluorescent product resorufin had formed. This photochemistry was initiated by trace amounts of resorufin that are present in Amplex Red stock solutions. ESR spin-trapping studies demonstrated that superoxide radical was an intermediate in this process. Oxygen consumption measurements further confirmed that superoxide and H2O2 were artifactually produced by the photooxidation of Amplex Red. The artifactual formation of resorufin was also significantly increased by the presence of superoxide dismutase or HRP. This photooxidation process will result in a less sensitive assay for H2O2 under ambient light exposure and potentially invalid measurements under high energy exposure such as UVA irradiation. In general, precautions should be taken to minimize exposure to light during measurement of oxidative stress with Amplex Red.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring reactive oxygen and nitrogen species with fluorescent probes: challenges and limitations
Kalyanaraman, B., Darley-Usmar, V., Davies, K. J. A., Dennery, P. A., Forman, H. J., Grisham, M. B., Mann, G. E., Moore, K., Roberts, L. J., & Ischiropoulos, H. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2011.09.030 · Cited by 1,774 · cited 1×
“While these probes can be highly sensitive, there are concerns about their specificity [1,2] and the potential for artifactual formation of ROS caused by the addition of the fluorescent probe to a biological sample in the presence of light [3,4].”
Zhou, M., Diwu, Z., Panchuk-Voloshina, N., & Haugland, R. P. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2391 · Cited by 1,396 · cited 2×
“Red can also be used to measure peroxidase activity and can detect as little as 1 10 5 U/ml HRP or, for H2O2, as little as 50 nM H2O2 [5].”
Wardman, P. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.06.026 · Cited by 864 · cited 1×
“While these probes can be highly sensitive, there are concerns about their specificity [1,2] and the potential for artifactual formation of ROS caused by the addition of the fluorescent probe to a biological sample in the presence of light [3,4].”
Mitochondrial α-Ketoglutarate Dehydrogenase Complex Generates Reactive Oxygen Species
Starkov, A. A., Fiskum, G., Chinopoulos, C., Lorenzo, B. J., Browne, S. E., Patel, M. S., & Beal, M. F. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.1899-04.2004 · Cited by 688
Mohanty, J. G., Jaffe, J. S., Schulman, E. S., & Raible, D. G. (1997) · Journal of Immunological Methods · doi:10.1016/s0022-1759(96)00244-x · Cited by 496
Kalyanaraman, B., Perez-Reyes, E., & Mason, R. P. (1980) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(80)90142-7 · Cited by 317
Self-citationRotenone Model of Parkinson Disease
Panov, A., Dikalov, S., Shalbuyeva, N., Taylor, G., Sherer, T., & Greenamyre, J. T. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m508628200 · Cited by 288
Votyakova, T. V., & Reynolds, I. J. (2004) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2004.07.025 · Cited by 207 · cited 2×
“In contrast, the presence of reductants such as NADH and GSH in a biological sample can also result in erroneously high resorufin formation because the radicals NAD and GS can be formed, which can then react with oxygen in air-saturated solutions to produce superoxide radical (O2 d ), which can in turn dismutate, lead…”
H2O2 Is an Important Mediator of UVB-Induced EGF-Receptor Phosphorylation in Cultured Keratinocytes
Peus, D., Vasa, R. A., Meves, A., Pott, M., Beyerle, A., Squillace, K., & Pittelkow, M. R. (1998) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1998.00210.x · Cited by 191 · cited 1×
“been implicated as a signaling molecule [16,17].”
Mechanistic Aspects of Horseradish Peroxidase Elucidated through Single-Molecule Studies
Gorris, H. H., & Walt, D. R. (2009) · Journal of the American Chemical Society · doi:10.1021/ja9008858 · Cited by 171 · cited 1×
“HRP catalyzes the oxidation of Amplex Red via two oneelectron oxidation steps in which an Amplex Red radical intermediate is formed [9].”
Hypoxic pulmonary vasoconstriction: redox events in oxygen sensing
Waypa, G. B., & Schumacker, P. T. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00722.2004 · Cited by 166
MICHELAKIS, E. (2004) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2004.09.007 · Cited by 165
Marchesi, E., Rota, C., Fann, Y. C., Chignell, C. F., & Mason, R. P. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(98)00174-9 · Cited by 162 · cited 1×
“While these probes can be highly sensitive, there are concerns about their specificity [1,2] and the potential for artifactual formation of ROS caused by the addition of the fluorescent probe to a biological sample in the presence of light [3,4].”
Self-citationDeYulia, G. J., Cárcamo, J. M., Bórquez-Ojeda, O., Shelton, C. C., & Golde, D. W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501154102 · Cited by 159 · cited 1×
“Confocal microscopy of Amplex Red samples has been done previously [26].”
Mishin, V. M., Gray, J. P., Heck, D. E., Laskin, D. L., & Laskin, J. D. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.02.030 · Cited by 155 · cited 2×
“Of greater concern was the exponentially increasing fluorescence generated in the presence of NADPH and NADPH-cytochrome P450 reductase when the Amplex Red assay was measured continuously but not when single measurements were taken [12].”
Towne, V., Will, M. L., Oswald, B., & Zhao, Q. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.07.037 · Cited by 149
Korge, P., Ping, P., & Weiss, J. N. (2008) · Circulation Research · doi:10.1161/circresaha.108.180869 · Cited by 137
H2O2 is required for UVB-induced EGF receptor and downstream signaling pathway activation
Péus, D., Meves, A., Vasa, R. A., Beyerle, A., O’Brien, T., & Pittelkow, M. R. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00198-7 · Cited by 98 · cited 1×
“been implicated as a signaling molecule [16,17].”
Bhattacharya, A., Müller, F. L., Liu, Y., Sabia, M., Liang, H., Song, W. J., Jang, Y. C., Ran, Q., & Remmen, H. V. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m806311200 · Cited by 98
Zhao, B., Ranguelova, K., Jiang, J., & Mason, R. P. (2011) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2011.03.016 · Cited by 76 · cited 4×
“While these probes can be highly sensitive, there are concerns about their specificity [1,2] and the potential for artifactual formation of ROS caused by the addition of the fluorescent probe to a biological sample in the presence of light [3,4].”
InfluentialSelf-citationReszka, K. J., Wagner, B. A., Burns, C. P., & Britigan, B. E. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.017 · Cited by 63 · cited 1×
“In addition, the concentration of H2O2 can be underestimated if a biological sample contains high levels of other peroxidase substrates, which may be endogenous compounds or exogenous compounds such as drugs, as these will compete with Amplex Red for oxidation by H2O2/HRP, resulting in less H2O2 available for the oxid…”
Measurement of Reactive Oxygen Species in Cells and Mitochondria
Armstrong, J. S., & Whiteman, M. (2007) · Methods in cell biology · doi:10.1016/s0091-679x(06)80018-x · Cited by 56 · cited 1×
“It may be more convenient to compare single measurements and continuous measurements by performing the experiments in a 96-well plate [12,25].”
Enhanced superoxide and hydrogen peroxide detection in biological assays
Rodrigues, J. V., & Gomes, C. M. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.03.014 · Cited by 50 · cited 1×
“The concentration of H2O2 can be underestimated if ascorbate or reduced superoxide reductase is present as they can inhibit resorufin formation by reacting with the Amplex Red radical intermediate, leading to the formation of ascorbyl radical and oxidized superoxide reductase, respectively [10].”
Yulia, D. (2005) · Medical Entomology and Zoology · Cited by 36
Generation of Oxidants by Hypoxic Human Pulmonary and Coronary Smooth-Muscle Cells
Mehta, J. P., Campian, J. L., Guardiola, J., Cabrera, J. A., Weir, Ε. K., & Eaton, J. W. (2008) · CHEST Journal · doi:10.1378/chest.07-2984 · Cited by 35 · cited 1×
“The levels of H2O2 in pulmonary and coronary smooth muscle cells have been reported to be lower in hypoxia than in normoxia [18], but there have been conflicting reports from other groups [19–21], underscoring the need to carefully control for potentially confounding variables.”
Cited by
Antibiotics induce redox-related physiological alterations as part of their lethality
Dwyer, D. J., Belenky, P. A., Yang, J. H., MacDonald, I. C., Martell, J. D., Takahashi, N., Chan, C. T. Y., Lobritz, M. A., Braff, D., Schwarz, E. G., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1401876111 · Cited by 948
Reuter, S., von Woedtke, T., & Weltmann, K.-D. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aab3ad · Cited by 522
Bøtker, H. E., Hausenloy, D., Andreadou, I., Antonucci, S., Boengler, K., Davidson, S. M., Deshwal, S., Devaux, Y., Di Lisa, F., Di Sante, M., et al. (2018) · Basic Research in Cardiology · doi:10.1007/s00395-018-0696-8 · Cited by 423
Antioxidant activity of nanomaterials
Valgimigli, L., Baschieri, A., & Amorati, R. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb00107c · Cited by 263
Makrecka-Kuka, M., Krumschnabel, G., & Gnaiger, E. (2015) · Biomolecules · doi:10.3390/biom5031319 · Cited by 242
“A brief literature survey indicates that AMR concentrations and media applied are highly variable, ranging from 1 μM AmR in PBS for the study of permeabilized C2C12 myoblasts and myotubes [25], 10 μM AmR in MiR05 for primary human skeletal myotubes [26], to 50 μM AmR in various phosphate-buffered or bicarbonate-buffer…”
Background
Metadata
- Authors
- Zhao, B., Summers, F. A., & Mason, R. P.
- Venue
- Free Radical Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2012-09
- Volume
- 53
- Issue
- 5
- Pages
- 1080-1087
- ISSN
- 0891-5849 (ISSN-L)
- OpenAlex
- W2070287747
- Cited by
- 194
- References
- 25
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.