Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cited by
Clutchable series-elastic actuator: Implications for prosthetic knee design
Rouse, E. J., Mooney, L. M., & Herr, H. M. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914545673 · Cited by 235
“Quasi-passive knees have been shown to increase self-selected walking speed as well as decrease peak vertical ground reaction force and metabolic cost, when compared to traditional passive knees (Segal et al., 2006; Kaufman et al., 2007; Johansson et al., 2005; Smith, 2007).”
Background‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218
“Instrumental gait analysis has become a valuable tool in clinical practice [1] establishing its usefulness particularly for children with cerebral palsy (CP) [7], but also for amputees [15, 24].”
Background
Metadata
- Authors
- Kaufman, K. R., Levine, J. A., Brey, R. H., Iverson, B. K., McCrady, S. K., Padgett, D. J., & Joyner, M. J.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2007-10
- Volume
- 26
- Issue
- 4
- Pages
- 489-493
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W1984655047
- Cited by
- 205
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees. https://app.cochat.ai/papers/10.1016/j.gaitpost.2007.07.011
- The paper
- Kaufman, K. R., Levine, J. A., Brey, R. H., Iverson, B. K., McCrady, S. K., Padgett, D. J., & Joyner, M. J. (2007). Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2007.07.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.