Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 218

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors

Open access
Cutti, Andrea Giovanni, Ferrari, Alberto, Garofalo, Pietro, Raggi, Michele, Cappello, Angelo, Ferrari, Adriano · 2010 · Medical & Biological Engineering & Computing

Abstract

A protocol named Outwalk was developed to easily measure the thorax–pelvis and lower-limb 3D kinematics on children with cerebral palsy (CP) and amputees during gait in free-living conditions, by means of an Inertial and Magnetic Measurement System (IMMS). Outwalk defines the anatomical/functional coordinate systems (CS) for each body segment through three steps: (1) positioning the sensing units (SUs) of the IMMS on the subjects’ thorax, pelvis, thighs, shanks and feet, following simple rules; (2) computing the orientation of the mean flexion–extension axis of the knees; (3) measuring the SUs’ orientation while the subject’s body is oriented in a predefined posture, either upright or supine. If the supine posture is chosen, e.g. when spasticity does not allow to maintain the upright posture, hips and knees static flexion angles must be measured through a standard goniometer and input into the equations that define Outwalk anatomical CSs. In order to test for the inter-rater measurement reliability of these angles, a study was carried out involving nine healthy children (7.9 ± 2 years old) and two physical therapists as raters. Results showed RMS error of 1.4° and 1.8° and a negligible worst-case standard error of measurement of 2.0° and 2.5° for hip and knee angles, respectively. Results were thus smaller than those reported for the same measures when performed through an optoelectronic system with the CAST protocol and support the beginning of clinical trials of Outwalk with children with CP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11517-009-0545-x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 218

Metadata

Authors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A.
Venue
Medical & Biological Engineering & Computing
Published
2009-11-13
Volume
48
Issue
1
Pages
17-25
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2037819518
Cited by
218
References
1
FWCI
4.43
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors. https://app.cochat.ai/papers/10.1007/s11517-009-0545-x
The paper
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2010). ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-009-0545-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.