The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Real-time gait event detection for normal subjects from lower trunk accelerations
Open accessAbstract
In this paper we report on a novel algorithm for the real-time detection and timing of initial (IC) and final contact (FC) gait events. We process the vertical and antero-posterior accelerations registered at the lower trunk (L3 vertebra). The algorithm is based on a set of heuristic rules extracted from a set of 1719 steps. An independent experiment was conducted to compare the results of our algorithms with those obtained from a Digimax force platform. The results show small deviations from times of occurrence of events recorded from the platform (13+/-35 ms for IC and 9+/-54 ms for FC). Results for the FC timing are especially relevant in this field, as no previous work has addressed its temporal location through the processing of lower trunk accelerations. The delay in the real-time detection of the IC is 117+/-39 ms and 34+/-72 ms for the FC, improving previously reported results for real-time detection of events from lower trunk accelerations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
Cited by
Del Din, S., Godfrey, A., & Rochester, L. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2419317 · Cited by 363
Gait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
Del Din, S., Godfrey, A., Galna, B., Lord, S., & Rochester, L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0154-5 · Cited by 349
Validity and repeatability of inertial measurement units for measuring gait parameters
Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.013 · Cited by 329
A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms
Caldas, R., Mundt, M., Potthast, W., Buarque de Lima Neto, F., & Markert, B. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.019 · Cited by 297
Metadata
- Authors
- González, R. C., López, A. M., Rodriguez-Uría, J., Álvarez, D., & Alvarez, J. C.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 31
- Issue
- 3
- Pages
- 322-325
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W1964304792
- Cited by
- 205
- References
- 2
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time gait event detection for normal subjects from lower trunk accelerations. https://app.cochat.ai/papers/10.1016/j.gaitpost.2009.11.014
- The paper
- González, R. C., López, A. M., Rodriguez-Uría, J., Álvarez, D., & Alvarez, J. C. (2010). Real-time gait event detection for normal subjects from lower trunk accelerations. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2009.11.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.