Cited by 460Gait Recognition and AnalysisBalance, Gait, and Falls PreventionLower Extremity Biomechanics and Pathologies

A practical gait analysis system using gyroscopes

Tong, Kaiyu, Granat, Malcolm H·1999·Medical Engineering & Physics

Abstract

This study investigated the possibility of using uni-axial gyroscopes to develop a simple portable gait analysis system. Gyroscopes were attached on the skin surface of the shank and thigh segments and the angular velocity for each segment was recorded in each segment. Segment inclinations and knee angle were derived from segment angular velocities. The angular signals from a motion analysis system were used to evaluate the angular velocities and the derived signals from the gyroscopes. There was a good correlation between these signals. When performing a turn the signals of segment inclination and knee angle drifted. Two methods were used to solve this: automatically resetting the system to re-initialise the angle in each gait cycle, and high-pass filtering. They both successfully corrected this drift. A single gyroscope on the shank segment could provide information on segment inclination range, cadence, number of steps, and an estimation of stride length and walking speed.

Integrity signals

Registry

Crossref · 10.1016/s1350-4533(99)00030-2

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Gyroscopes are suitable for ungrounded tremor assessment because they measure rotational motion and are not influenced by gravity.

    “The main advantages of using gyroscopes are [13]: they measure rotational motion (human motion is rotational about joints), they are not influenced by gravity, both frequency and amplitude information accurate down to direct current (dc) (zero frequency), based on mathematical operations it is possible to obtain angular displacement and acceleration, high signal-to-noise ratio, high dynamic range,”
  • Gyroscopes in combination with accelerometers record both linear and angular motion, reducing calibration biases.

    “Gyroscopes in combination with accelerometers have the advantage that both linear and angular motion is recorded [36], [37], reducing calibration biases.”

Cited by

Sorted by citations

Authors
Tong, K., & Granat, M. H.
Affiliations
University of Strathclyde (GB)
Corresponding author
Granat, Malcolm H
Venue
Medical Engineering & Physics
Published
1999-03-01
Volume
21
Issue
2
Pages
87-94
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1992589116
Cited by
460
References
0
Citations by year
2026: 2 · 2025: 6 · 2024: 7 · 2023: 12 · 2022: 17 · 2021: 22 · 2020: 19 · 2019: 26 · 2018: 38 · 2017: 23 · 2016: 25 · 2015: 27 · 2014: 25 · 2013: 36 · 2012: 27
FWCI
3.21
Type
journal article
Language
en
Open access
closed
Locations
  • Medical Engineering & Physics (publishedVersion)
  • PubMed (publishedVersion)
Funders
University of Strathclyde
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
gait analysis, wearable sensors, knee joint angle, angular velocity, drift correction, high-pass filtering, stride length estimation, walking speed, cadence
MeSH terms
Algorithms, Ankle, Biomechanical Phenomena, Gait, Humans, Knee, Tibia, Time Factors, Transducers, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review