Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 533

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Comparative effectiveness of biliary brush cytology and intraductal biopsy for detection of malignant biliary strictures: a systematic review and meta-analysis

Open access
Navaneethan, Udayakumar, Njei, Basile, Lourdusamy, Vennisvasanth, Konjeti, Rajesh, Vargo, John J., Parsi, Mansour A.·2015·Gastrointestinal Endoscopy

Abstract

Background Evaluation of indeterminate biliary strictures typically involves collection and analysis of tissue or cells. Brush cytology and intraductal biopsies that are routinely performed during ERCP to assess malignant-appearing biliary strictures are limited by relatively low sensitivity. Objective To study the comparative effectiveness of brushings for cytology and intraductal biopsies in the etiology of biliary strictures. Design Meta-analysis. Setting Referral center. Patients PUBMED and Embase databases were reviewed for studies published to April 2014 where diagnostic correlation of histology was available. Intervention Database and review of study findings. Main Outcome Measurements Sensitivity and specificity. Results The pooled sensitivity and specificity of brushings for the diagnosis of malignant biliary strictures was 45% (95% confidence interval [CI], 40%–50%) and 99% (95% CI, 98%–100%), respectively. The pooled diagnostic odds ratio to detect malignant biliary strictures was 33.43 (95% CI, 14.29–78.24). For intraductal biopsies, the pooled sensitivity and specificity were 48.1% (95% CI, 42.8%–53.4%) and 99.2% (95% CI, 97.6%–99.8%), respectively. The pooled diagnostic odds ratio to detect malignant biliary strictures was 43.18 (95% CI, 19.39–95.83). A combination of both modalities only modestly increased the sensitivity (59.4%; 95% CI, 53.7%–64.8%) with a specificity of 100% (95% CI, 98.8%–100.0%). The Begg-Mazumdar and Egger tests indicated a low potential for publication bias. Limitations Inclusion of low-quality studies. Conclusion Our study suggests that both brushings and biopsy are comparable and have limited sensitivity for the diagnosis of malignant biliary strictures. A combination of both only modestly increases the sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2014.09.017

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 533

Metadata

Authors
Navaneethan, U., Njei, B., Lourdusamy, V., Konjeti, R., Vargo, J. J., & Parsi, M. A.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2015-01
Volume
81
Issue
1
Pages
168-176
ISSN
0016-5107 (ISSN-L)
OpenAlex
W2038265408
Cited by
533
References
23
FWCI
3.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative effectiveness of biliary brush cytology and intraductal biopsy for detection of malignant biliary strictures: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.gie.2014.09.017
The paper
Navaneethan, U., Njei, B., Lourdusamy, V., Konjeti, R., Vargo, J. J., & Parsi, M. A. (2015). Comparative effectiveness of biliary brush cytology and intraductal biopsy for detection of malignant biliary strictures: a systematic review and meta-analysis. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2014.09.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.