CoChat

Computer-aided diagnosis for characterization of colorectal lesions: comprehensive software that includes differentiation of serrated lesions

Zorron Cheng Tao Pu, Leonardo, Maicas, Gabriel, Tian, Yu, Yamamura, Takeshi, Nakamura, Masanao, Suzuki, Hiroto, Singh, Gurfarmaan, Rana, Khizar, Hirooka, Yoshiki, Burt, Alastair D., Fujishiro, Mitsuhiro, Carneiro, Gustavo, Singh, Rajvinder · 2020 · Gastrointestinal Endoscopy
Cited by 54

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS Endoscopy guidelines recommend adhering to policies such as resect-and-discard only if optical biopsy is accurate. However, accuracy in predicting histology can vary greatly. Computer-aided diagnosis (CAD) for characterization of colorectal lesions may help with this issue. In this study, a CAD software developed at the University of Adelaide (Australia) including serrated polyp differentiation was validated with Japanese images on narrow-band imaging (NBI) and blue-laser imaging (BLI). METHODS A CAD software developed using machine learning, densely connected convolutional neural networks was modeled with NBI colorectal lesion images (Olympus 190 series - Australia) and validated for NBI (Olympus 290 series) and BLI (Fujifilm 700 series) with Japanese datasets. All images were correlated with histology according to the modified Sano's classification. The CAD was trained with Australian NBI images and tested with separate sets of images from Australia (NBI) and Japan (NBI and BLI). RESULTS An Australian dataset of 1,235 polyp images was used as training, testing, and internal validation sets. A Japanese dataset of 20 polyp images on NBI and 49 polyp images on BLI was used as external validation sets. The CAD software had a mean area under the curve (AUC) of 94.3% for the internal set and 84.5% and 90.3% for the external sets (NBI and BLI, respectively). CONCLUSIONS The CAD achieved AUC comparable with experts and similar results with NBI and BLI. Accurate CAD prediction was achievable even when the predicted endoscopy imaging technology was not part of the training set.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2020.02.042

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Zorron Cheng Tao Pu, L., Maicas, G., Tian, Y., Yamamura, T., Nakamura, M., Suzuki, H., Singh, G., Rana, K., Hirooka, Y., Burt, A. D., Fujishiro, M., Carneiro, G., & Singh, R.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2020-10
Volume
92
Issue
4
Pages
891-899
ISSN
0016-5107 (ISSN-L)
OpenAlex
W3010465795
Cited by
54
References
6
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.