The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index; 40 of the 55 sources its claims cite were checked for support.
Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy
Open accessAbstract
PURPOSE: Early clinical recognition of sepsis can be challenging. With the advancement of machine learning, promising real-time models to predict sepsis have emerged. We assessed their performance by carrying out a systematic review and meta-analysis. METHODS: A systematic search was performed in PubMed, Embase.com and Scopus. Studies targeting sepsis, severe sepsis or septic shock in any hospital setting were eligible for inclusion. The index test was any supervised machine learning model for real-time prediction of these conditions. Quality of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, with a tailored Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist to evaluate risk of bias. Models with a reported area under the curve of the receiver operating characteristic (AUROC) metric were meta-analyzed to identify strongest contributors to model performance. RESULTS: After screening, a total of 28 papers were eligible for synthesis, from which 130 models were extracted. The majority of papers were developed in the intensive care unit (ICU, n = 15; 54%), followed by hospital wards (n = 7; 25%), the emergency department (ED, n = 4; 14%) and all of these settings (n = 2; 7%). For the prediction of sepsis, diagnostic test accuracy assessed by the AUROC ranged from 0.68-0.99 in the ICU, to 0.96-0.98 in-hospital and 0.87 to 0.97 in the ED. Varying sepsis definitions limit pooling of the performance across studies. Only three papers clinically implemented models with mixed results. In the multivariate analysis, temperature, lab values, and model type contributed most to model performance. CONCLUSION: This systematic review and meta-analysis show that on retrospective data, individual machine learning models can accurately predict sepsis onset ahead of time. Although they present alternatives to traditional scoring systems, between-study heterogeneity limits the assessment of pooled results. Systematic reporting and clinical implementation studies are needed to bridge the gap between bytes and bedside.
Overview
CoChat Summary
TL;DR
This systematic review and meta-analysis of 28 papers and 130 machine learning models found that models retrospectively predict sepsis with AUROC ranges of 0.68–0.99 in the ICU, 0.96–0.98 in-hospital, and 0.87–0.97 in the ED. Between-study heterogeneity, varying sepsis definitions, and scarce prospective/clinical implementation studies limit pooled assessment and evidence on patient outcomes.
Key findings
- From 28 eligible papers, 130 models were extracted; most studies were in the ICU (n = 15; 54%), followed by hospital wards (n = 7; 25%), ED (n = 4; 14%), and all settings (n = 2; 7%). Reported AUROCs for sepsis ranged from 0.68–0.99 in the ICU, 0.96–0.98 in-hospital, and 0.87–0.97 in the ED; septic shock predictions ranged from 0.86–0.94 in-hospital and 0.83–0.96 in the ICU.
- All studies reported retrospective diagnostic test accuracy; models were prospectively validated in 2 papers (7%) and clinically implemented in 3 papers (11%), with mixed results.
- In the meta-analysis of 111 models, temperature (multivariate coefficient 0.812, p = 0.000), lab values (0.842, p = 0.003), and model type (p = 0.020) contributed most to model performance. Univariate positive contributors included heart rate, respiratory rate, temperature, lab values, arterial blood gas values, and neural networks; negative contributors included the Seymour et al. Sepsis-3 definition, SOFA in the target condition definition, and models other than ensemble methods or neural networks.
- Risk of bias was unclear in 9/28 papers (32%) and high in all others; all papers had unclear risk of bias for the reference standard, and GRADE quality of evidence was low for each hospital setting.
Methods
- Systematic review and meta-analysis conducted per PRISMA-DTA, registered on PROSPERO (CRD42019118716). Searches were run in PubMed, Embase.com, and Scopus up to September 13, 2019, for adult patients in any hospital setting, targeting right-aligned supervised machine learning models predicting sepsis, severe sepsis, or septic shock.
- After screening 2,684 papers, 130 full texts were read and 28 papers met inclusion criteria; 130 models were retrieved. Quality of evidence used GRADE, and risk of bias used a tailored QUADAS-2 checklist combined with an adapted Joanna Briggs Institute checklist.
- Meta-analysis used AUROC as the main metric, logit-transformed; a linear random effect model with a paper-specific random effect accounted for multiple models per paper. After grouping features and removing low-variance or collinear covariates, 39 covariates were analyzed, with backward AIC selection for the multivariate model; analyses were carried out in R.
Limitations
- Paper-stated: AUROC was chosen pragmatically and may underperform with imbalanced datasets; no contingency tables were feasible because necessary data were infrequently reported; few papers reported confidence intervals or standard deviations; heterogeneity in sepsis definitions, settings, and models prevented computing an overall pooled point estimate; there is no gold standard for diagnosing sepsis; high risk of bias and low GRADE evidence.
- Paper-stated: all models were developed in the United States, many used the MIMIC database, and no models were developed or validated in middle- or low-income countries; code was not released by any study, and only one paper reported adhering to a reporting standard.
- Evident from the text: only 3 interventional/implementation studies and 2 prospective validation studies were identified, so clinical impact on patient-relevant outcomes remains uncertain; the review is dominated by retrospective diagnostic accuracy studies.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
18 Valid · 6 Not valid · 7 Not checked · 73 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Early clinical recognition of sepsis can be challenging.”
- Also stated in: § Introduction · plain
“early recognition can be difficult due to disease complexity in clinical context [9, 10] and heterogeneity of the septic population [11].”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Abstract > Purpose
What the sources say
- Supportedcites [9] Vincent J-L (2016) The clinical challenge of sepsis identification and monitoring. PLoS Med 13:e1002022. https://doi.org/10.1371/journal.pmed.1002022 source
The Introduction—The Clinical Problem states that early diagnosis of sepsis remains a challenge for bedside clinicians. The “Diagnosis” of Infection and Sepsis section also explains that diagnosis is not always straightforward, particularly in critically ill patients with comorbidities and other disease processes. (LLM, conf=0.94)
- Could not verifycites [10] Talisa VB, Yende S, Seymour CW, Angus DC (2018) Arguing for adaptive clinical trials in sepsis. Front Immunol 9:1502. https://doi.org/10.3389/fimmu.2018.01502 sourceExperimental — accuracy not yet measured
The Introduction and “Sepsis Is Extremely Heterogeneous” section describe patient heterogeneity as a challenge for developing treatments and conducting trials, not for early clinical recognition. Searches for early recognition and diagnosis found no passage addressing whether clinicians have difficulty recognizing sepsis early. (LLM, conf=0.75)
- Could not verifycites [11] de Grooth H-J, Postema J, Loer SA et al (2018) Unexplained mortality differences between septic shock trials: a systematic analysis of population characteristics and control-group mortality rates. Intensive Care Med 44:311–322. https://doi.org/10.1007/s00134-018-5134-8 sourceExperimental — accuracy not yet measured
The Conclusion describes septic shock as heterogeneous, and the Discussion addresses differences in trial definitions and populations. Neither section addresses whether early clinical recognition of sepsis is challenging; searches for early recognition and diagnostic difficulty found no passage that does. (LLM, conf=0.72)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Introduction · plain
Every source the paper cites for this claim was checked and supports it.
In the paper
“One clinical validation study in the ED showed the machine learning model outperformed manual scoring by nurses and the SIRS criteria when identifying severe sepsis and septic shock [28], the other study made no comparison [29].”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Results > Study characteristics
What the sources say
- Supportedcites [28] Brown SM, Jones J, Kuttler KG et al (2016) Prospective evaluation of an automated method to identify patients with severe sepsis or septic shock in the emergency department. BMC Emerg Med 16:1–7. https://doi.org/10.1186/s12873-016-0095-0 source
The Overall model performance section (page unavailable) directly compares the ED model with the triage-nurse identification process and a SIRS-derived rule. The model had higher AUC and sensitivity than both for identifying severe sepsis or septic shock, although its false-positive rate was also higher. The paper describes a nurse identification process rather than a formal manual score. (LLM, conf=0.90)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“very few papers reported they accept data inquiries [32, 35, 47]”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Discussion > Future directions and academic contribution
What the sources say
- Could not verifycites [32] Shimabukuro DW, Barton CW, Feldman MD et al (2017) Effect of a machine learning-based severe sepsis prediction algorithm on patient survival and hospital length of stay: a randomised clinical trial. BMJ Open Respir Res 4:e000234. https://doi.org/10.1136/bmjresp-2017-000234 sourceExperimental — accuracy not yet measured
The Methods section describes collecting patient data, but the passages from our copy do not say whether the authors accept inquiries or requests for those data. Searches for data availability, data sharing, and requests to the authors found no such statement. This paper also cannot establish how many papers in the citing document’s set reported accepting inquiries. (LLM, conf=0.70)
- Could not verifycites [35] Horng S, Sontag DA, Halpern Y et al (2017) Creating an automated trigger for sepsis clinical decision support at emergency department triage using machine learning. PLoS One 12:e0174708. https://doi.org/10.1371/journal.pone.0174708 sourceExperimental — accuracy not yet measured
The Data collection and processing section describes the patient data used in the study, but does not say whether the authors accept inquiries or requests for those data. Searches for data inquiries, availability statements, and access requests found no passage addressing that point; the paper also does not assess how many other papers accept inquiries. (LLM, conf=0.72)
- Supportedcites [47] Brown SM, Jones J, Kuttler KG et al (2016) Prospective evaluation of an automated method to identify patients with severe sepsis or septic shock in the emergency department. BMC Emerg Med 16:31. https://doi.org/10.1186/s12873-016-0095-0 source
The Data availability section says requests for deidentified data will be processed for qualified researchers with appropriate ethics approval and data-use agreements. This supports citing the paper as an example that accepts data inquiries; the statement that very few papers do so is the citing authors’ assessment of the group. (LLM, conf=0.91)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Interventional studies using traditional SIRS and SOFA alarm systems have not shown significant changes in clinical outcomes [48–50].”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Discussion > Clinical model performance
What the sources say
- Could not verifycites [48] Nguyen SQ, Mwakalindile E, Booth JS et al (2014) Automated electronic medical record sepsis detection in the emergency department. PeerJ 2:e343. https://doi.org/10.7717/peerj.343 sourceExperimental — accuracy not yet measured
The Methods (Selection of subjects) say the SIRS-based alerts were evaluated after the fact and were not communicated to clinicians. The Limitations state that the study assessed detection accuracy, not clinical implementation. Our copy does not report an interventional study of SIRS or SOFA alarms or whether such alarms changed clinical outcomes. (LLM, conf=0.79)
- Not checked — no full text of the sourcecites [49] Nelson JL, Smith BL, Jared JD, Younger JG (2011) Prospective trial of real-time electronic surveillance to expedite early care of severe sepsis. Ann Emerg Med 57:500–504. https://doi.org/10.1016/j.annemergmed.2010.12.008 source
- Partly supportedcites [50] Hooper MH, Weavind L, Wheeler AP et al (2012) Randomized trial of automated, electronic monitoring to facilitate early detection of sepsis in the intensive care unit. Crit Care Med 40:2096–2101. https://doi.org/10.1097/CCM.0b013e318250a887 sourceExperimental — accuracy not yet measured
The Abstract (Conclusions) and Results report that this modified-SIRS alert trial did not significantly change measured clinical outcomes, including ICU length of stay and mortality. The cited study tested modified SIRS alerts in one ICU; it does not support the sentence’s reference to SOFA alarm systems. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“Many studies use ICD coding, which may be an unreliable instrument to identify septic patients [44, 45].”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Discussion > Heterogeneity and pooled performance
What the sources say
- Supportedcites [44] Fleischmann-Struzek C, Thomas-Rüddel DO, Schettler A et al (2018) Comparing the validity of different ICD coding abstraction strategies for sepsis case identification in German claims data. PLoS One 13:e0198847. https://doi.org/10.1371/journal.pone.0198847 source
The Introduction says sepsis estimates in the US and several European countries are commonly drawn from studies using ICD codes to identify cases. The Results (Validation of ICD code abstraction strategies) show why that identification may be unreliable: some strategies underestimated cases by up to 3.5-fold, while implicit coding produced substantial false positives. (LLM, conf=0.94)
- Supportedcites [45] Bouza C, Lopez-Cuadrado T, Amate-Blanco JM (2016) Use of explicit ICD9-CM codes to identify adult severe sepsis: impacts on epidemiological estimates. Crit Care 20:313. https://doi.org/10.1186/s13054-016-1497-9 source
The Background says population-based severe-sepsis studies commonly use ICD-9-CM codes, but that coding strategies can bias case identification and some combination algorithms have poor specificity. This supports the hedged concern about using ICD coding to identify septic patients, though the paper specifically examines adult severe sepsis. (LLM, conf=0.88)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
45 more claims · 1 with their cited sources checked
Create a free account to see all 104 claims and to verify the 2 references still open.
- Probably not a substantial claim. 31
- It may state two separate claims as one. 31
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For instance, AI models for sepsis prediction can alert clinicians to septic events hours before clinical signs emerge, enabling timely interventions [5].”
From Expectations of Intensive Care Physicians Regarding an AI-Based Decision Support System for Weaning From Continuous Renal Replacement Therapy: Predevelopment Survey Study (2025) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Two prominent examples relevant to critical care are models using readily available EHR data that can accurately predict clinical deterioration and sepsis hours before they occur [28–33]; these models exemplify real-time CDSS that alert clinicians and prompt evaluation, testing, and interventions [33].”
From Use of artificial intelligence in critical care: opportunities and obstacles (2024) · cites this paper as [32]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Among studies that reported the performance of sepsis prediction model in the ED, AUROCs ranged from 0.87 to 0.97.17”
From Development and validation of a screening tool for sepsis without laboratory results in the emergency department: a machine learning study (2025) · cites this paper as [17]
The cited source says what the claim attributes to it.
In the citing paper
“Despite the rise in competing models and products for early sepsis detection [5], few machine learning models have been implemented as part of clinical care [6-8].”
From Integrating a Machine Learning System Into Clinical Workflows: Qualitative Study (2020) · cites this paper as [5]
In the citing paper
“A recent systematic review demonstrated that ML models can accurately predict onset of sepsis in ICU patients [17].”
From Moving from bytes to bedside: a systematic review on the use of artificial intelligence in the intensive care unit (2021) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Discussion > Clinical model performance
“Only one study clinically validated their model and showed that these models outperformed nurse triaging and SIRS criteria in the emergency room [47].”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Results > Study characteristics
“Prospective studies included two clinical validation studies (ED and in-hospital) and three interventional studies (in-hospital and ICU).”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Results > Study characteristics
“| Prospective design | 1 | 0.25 | 2 | 0.29 | 1 | 0.07 |”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Results > Study characteristics
“The interventional studies included two pre-post implementation studies (in-hospital) [30, 31] and one ICU randomized controlled trial [32].”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“| Data granularity | | | | | | | | 1-hourly values | – | – | 6 | 0.14 | 30 | 0.58 | | > 1/hourly values | – | – | 0 | 0.00 | 18 | 0.35 | | Not described | – | – | 31 | 0.72 | 4 | 0.08 |”
§ Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy > Results > Study characteristics
Reported 43 · recomputed 37
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
The third international consensus definitions for sepsis and septic shock (Sepsis-3).
Singer, M., Deutschman, C. S., Seymour, C. W., Shankar-Hari, M., Annane, D., Bauer, M., Bellomo, R., Bernard, G. R., Chiche, J.-D., Coopersmith, C. M., et al. (2016) · JAMA · doi:10.1001/jama.2016.0287 · Cited by 28,250
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Proceedings of the 24th international conference on Machine learning
(2007) · doi:10.1145/1273496 · Cited by 11,630
He, H., & Garcia, E. A. (2009) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2008.239 · Cited by 10,359
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
Kumar, A., Roberts, D., Wood, K. E., Light, B., Parrillo, J. E., Sharma, S., Suppes, R., Feinstein, D., Zanotti, S., Taiberg, L., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000217961.75225.e9 · Cited by 6,109
Seymour, C. W., Liu, V. X., Iwashyna, T. J., Brunkhorst, F. M., Rea, T. D., Scherag, A., Rubenfeld, G., Kahn, J. M., Shankar-Hari, M., Singer, M., et al. (2016) · JAMA · doi:10.1001/jama.2016.0288 · Cited by 3,939
Fleischmann, C., Scherag, A., Adhikari, N. K. J., Hartog, C. S., Tsaganos, T., Schlattmann, P., Angus, D. C., & Reinhart, K. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201504-0781oc · Cited by 3,548
McInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Research works printed but not linked: 3
- Brown SM, Jones J, Kuttler KG et al (2016) Prospective evaluation of an automated method to identify patients with severe sepsis or septic shock in the emergency department. BMC Emerg Med 16:31. https://doi.org/10.1186/s12873-016-0095-0 · DOI · Paper page
- Giannini HM, Ginestra JC, Chivers C et al (2019) A machine learning algorithm to predict severe sepsis and septic shock: development, implementation, and impact on clinical practice. Crit Care Med. https://doi.org/10.1097/CCM.0000000000003891 · DOI · Paper page
- Mao Q, Jay M, Hoffman JL et al (2018) Multicentre validation of a sepsis prediction algorithm using only vital sign data in the emergency department, general ward and ICU. BMJ Open 8:e017833. https://doi.org/10.1136/bmjopen-2017-017833 · DOI · Paper page
Cited by
Liu, X., Cruz Rivera, S., Moher, D., Calvert, M. J., Denniston, A. K., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Chan, A.-W., Darzi, A., Holmes, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1034-x · Cited by 1,421
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Darzi, A., Holmes, C., Yau, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1037-7 · Cited by 933
Liu, X., Rivera, S. C., Moher, D., Calvert, M. J., & Denniston, A. K. (2020) · BMJ · doi:10.1136/bmj.m3164 · Cited by 702
Liu, X., Cruz Rivera, S., Moher, D., Calvert, M. J., Denniston, A. K., Ashrafian, H., Beam, A. L., Chan, A.-W., Collins, G. S., Deeks, A. D. J., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30218-1 · Cited by 555
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., Ashrafian, H., Beam, A. L., Collins, G. S., Darzi, A., Deeks, J. J., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30219-3 · Cited by 486
Metadata
- Authors
- Fleuren, L. M., Klausch, T. L. T., Zwager, C. L., Schoonmade, L. J., Guo, T., Roggeveen, L. F., Swart, E. L., Girbes, A. R. J., Thoral, P., Ercole, A., Hoogendoorn, M., & Elbers, P. W. G.
- Affiliations
- Amsterdam Cardiovascular Sciences (NL)
- Vrije Universiteit Amsterdam (NL)
- University of Cambridge (GB)
- European Society of Intensive Care Medicine (BE)
- Corresponding author
- Fleuren, Lucas M.
- ORCID
- Venue
- Intensive Care Medicine
- Published
- 2020-01-21
- Volume
- 46
- Issue
- 3
- Pages
- 383-400
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- PMC
- PMC7067741
- OpenAlex
- W2992764683
- Semantic Scholar
- b47dffe8e582aff39c5ee2bd5b6f4628a53641b0
- Cited by
- 755
- References
- 68
- Citations by year
- 2026: 142 · 2025: 142 · 2024: 130 · 2023: 124 · 2022: 118 · 2021: 75 · 2020: 24
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- creativecommons.org/licenses/by-nc/4.0 (tdm)
- creativecommons.org/licenses/by-nc/4.0 (vor)
- Locations
- Intensive Care Medicine (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion, cc-by)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion, other-oa)
- VU Research Portal (publishedVersion, other-oa)
- Apollo (University of Cambridge) (submittedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by-nc)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Apollo
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- sepsis prediction, machine learning, diagnostic accuracy, septic shock, severe sepsis, area under the curve, intensive care unit, emergency department, sepsis definitions, clinical implementation
- MeSH terms
- Machine Learning, Diagnostic Tests, Routine, Humans, Retrospective Studies, Shock, Septic, Sepsis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy. https://app.cochat.ai/papers/10.1007/s00134-019-05872-y
- The paper
- Fleuren, L. M., Klausch, T. L. T., Zwager, C. L., Schoonmade, L. J., Guo, T., Roggeveen, L. F., Swart, E. L., Girbes, A. R. J., Thoral, P., Ercole, A., Hoogendoorn, M., & Elbers, P. W. G. (2020). Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy. Intensive Care Medicine. https://doi.org/10.1007/s00134-019-05872-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.