CoChat

Impact of the clinical use of artificial intelligence–assisted neoplasia detection for colonoscopy: a large-scale prospective, propensity score–matched study (with video)

Ishiyama, Misaki, Kudo, Shin-ei, Misawa, Masashi, Mori, Yuichi, Maeda, Yasuhara, Ichimasa, Katsuro, Kudo, Toyoki, Hayashi, Takemasa, Wakamura, Kunihiko, Miyachi, Hideyuki, Ishida, Fumio, Itoh, Hayato, Oda, Masahiro, Mori, Kensaku · 2022 · Gastrointestinal Endoscopy
Cited by 40

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS Recently, the use of computer-aided detection (CADe) for colonoscopy has been investigated to improve the adenoma detection rate (ADR). We aimed to assess the efficacy of a regulatory-approved CADe in a large-scale study with high numbers of patients and endoscopists. METHODS This was a propensity score matched prospective study that took place at a university hospital between July 2020 and December 2020. We recruited patients aged ≥20 years who were scheduled for colonoscopy. Patients with polyposis, inflammatory bowel disease, or incomplete colonoscopy were excluded. We used a regulatory-approved CADe and conducted a propensity score matching-based comparison of the ADR between patients examined with and without CADe as the primary outcome. RESULTS During the study period, 2,261 patients underwent colonoscopy with the CADe system or routine colonoscopy and 175 patients were excluded in accordance with the exclusion criteria. Thirty endoscopists (9 nonexperts and 21 experts) were involved in this study. Propensity score matching was conducted using 5 factors, resulting in 1,836 patients included in the analysis (918 patients in each group). The ADR was significantly higher in the CADe group than in the control group (26.4% vs 19.9%, respectively; relative risk [OR], 1.32; 95% confidence interval [CI], 1.12-1.57); however, there was no significant increase in the advanced neoplasia detection rate (3.7% vs 2.9%, respectively). CONCLUSIONS The use of the CADe system for colonoscopy significantly increased the ADR in a large-scale prospective study including 30 endoscopists. (UMIN-CTR: UMIN000040677.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2021.07.022

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 40

Metadata

Authors
Ishiyama, M., Kudo, S.-E., Misawa, M., Mori, Y., Maeda, Y., Ichimasa, K., Kudo, T., Hayashi, T., Wakamura, K., Miyachi, H., Ishida, F., Itoh, H., Oda, M., & Mori, K.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2022-01
Volume
95
Issue
1
Pages
155-163
ISSN
0016-5107 (ISSN-L)
OpenAlex
W3192659802
Cited by
40
References
14
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of the clinical use of artificial intelligence–assisted neoplasia detection for colonoscopy: a large-scale prospective, propensity score–matched study (with video). https://app.cochat.ai/papers/10.1016/j.gie.2021.07.022
The paper
Ishiyama, M., Kudo, S.-E., Misawa, M., Mori, Y., Maeda, Y., Ichimasa, K., Kudo, T., Hayashi, T., Wakamura, K., Miyachi, H., Ishida, F., Itoh, H., Oda, M., & Mori, K. (2022). Impact of the clinical use of artificial intelligence–assisted neoplasia detection for colonoscopy: a large-scale prospective, propensity score–matched study (with video). Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2021.07.022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.