CoChat

Artificial Intelligence–Assisted Colonoscopy in Real-World Clinical Practice: A Systematic Review and Meta-Analysis

Open access
Wei, Mike Tzuhen, Fay, Shmuel, Yung, Diana, Ladabaum, Uri, Kopylov, Uri · 2024 · Clinical and Translational Gastroenterology

The DOI matches its Crossref record; 22 of the 23 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Artificial intelligence (AI) could minimize the operator-dependent variation in colonoscopy quality. Computer-aided detection (CADe) has improved adenoma detection rate (ADR) and adenomas per colonoscopy (APC) in randomized controlled trials. There is a need to assess the impact of CADe in real-world settings. METHODS: We searched MEDLINE, EMBASE, and Web of Science for nonrandomized real-world studies of CADe in colonoscopy. Random-effects meta-analyses were performed to examine the effect of CADe on ADR and APC. The study is registered under PROSPERO (CRD42023424037). There was no funding for this study. RESULTS: Twelve of 1,314 studies met inclusion criteria. Overall, ADR was statistically significantly higher with vs without CADe (36.3% vs 35.8%, risk ratio [RR] 1.13, 95% confidence interval [CI] 1.01–1.28). This difference remained significant in subgroup analyses evaluating 6 prospective (37.3% vs 35.2%, RR 1.15, 95% CI 1.01–1.32) but not 6 retrospective (35.7% vs 36.2%, RR 1.12, 95% CI 0.92–1.36) studies. Among 6 studies with APC data, APC rate ratio with vs without CADe was 1.12 (95% CI 0.95–1.33). In 4 studies with GI Genius (Medtronic), there was no difference in ADR with vs without CADe (RR 0.96, 95% CI 0.85–1.07). DISCUSSION: ADR, but not APC, was slightly higher with vs without CADe among all available real-world studies. This difference was attributed to the results of prospective but not retrospective studies. The discrepancies between these findings and those of randomized controlled trials call for future research on the true impact of current AI technology on colonoscopy quality and the subtleties of human-AI interactions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.14309/ctg.0000000000000671

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Study selection. Flowchart of the study selection process.
Figure 1. Study selection. Flowchart of the study selection process.CC BY-NC-ND · PubMed Central
Figure 2. Pooled ADR risk ratio of all studies including abstracts. ADR, adenoma detection rate; CADe, computer-assisted detection.
Figure 2. Pooled ADR risk ratio of all studies including abstracts. ADR, adenoma detection rate; CADe, computer-assisted detection.CC BY-NC-ND · PubMed Central
Figure 3. Pooled rate ratio for APC with vs without CADe. APC, Adenoma per colonoscopy; CADe, computer-assisted detection.
Figure 3. Pooled rate ratio for APC with vs without CADe. APC, Adenoma per colonoscopy; CADe, computer-assisted detection.CC BY-NC-ND · PubMed Central
Figure 4. Pooled ADR risk ratio of full studies evaluating only GI Genius. ADR, adenoma detection rate; CADe, computer-assisted detection.
Figure 4. Pooled ADR risk ratio of full studies evaluating only GI Genius. ADR, adenoma detection rate; CADe, computer-assisted detection.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Research works printed but not linked: 2

  1. Ahmad, 2021, Early evaluation of a computer assisted polyp detection system in bowel cancer screening, Gut, A42
  2. Agazzi, 2021, Real-time artificial intelligence-aided colonoscopy experience: The impact on routine clinical practice in a high-volume center-preliminary data, United Eur Gastroenterol J, 813

Cited by

See all 74

Metadata

Authors
Wei, M. T., Fay, S., Yung, D., Ladabaum, U., & Kopylov, U.
Affiliations
  • Stanford Medicine (US)
  • Tel Aviv University (IL)
  • Gold Coast Hospital (AU)
Corresponding author
  • Wei, Mike Tzuhen
  • Fay, Shmuel
  • Ladabaum, Uri
  • Kopylov, Uri
Venue
Clinical and Translational Gastroenterology
Published
2023-12-26
Volume
15
Issue
3
Pages
e00671
ISSN
2155-384X (ISSN-L)
OpenAlex
W4390228412
Cited by
57
References
23
Citations by year
2026: 20 · 2025: 21 · 2024: 16
FWCI
1.85
Type
journal article
Language
en
Open access
Locations
  • Clinical and Translational Gastroenterology (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Oncology › Colorectal Cancer Screening and Detection
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
artificial intelligence, computer-aided detection, colonoscopy, adenoma detection rate, colonoscopy quality, real-world evidence, GI Genius, human-AI interaction, colorectal cancer screening
MeSH terms
Adenoma, Artificial Intelligence, Colonic Polyps, Colonoscopy, Diagnosis, Computer-Assisted, Humans, Colorectal Neoplasms, Early Detection of Cancer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence–Assisted Colonoscopy in Real-World Clinical Practice: A Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.14309/ctg.0000000000000671
The paper
Wei, M. T., Fay, S., Yung, D., Ladabaum, U., & Kopylov, U. (2024). Artificial Intelligence–Assisted Colonoscopy in Real-World Clinical Practice: A Systematic Review and Meta-Analysis. Clinical and Translational Gastroenterology. https://doi.org/10.14309/ctg.0000000000000671

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.