The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Second INTERMACS annual report: More than 1,000 primary left ventricular assist device implants
Open accessAbstract
The Interagency Registry For Mechanical Circulatory Support (INTERMACS)1 an NHLBI-sponsored collaboration between the National Heart, Lung, and Blood Institute (NHLBI), the Food and Drug Administration (FDA), the Center for Medicaid and Medicare Services (CMS), and the advanced heart failure/mechanical circulatory support professional community, began prospective patient enrollment and data collection on June 23, 2006. On 3/27/09, CMS mandated that all United States hospitals approved for mechanical circulatory support as Destination Therapy (DT) must enter mechanical circulatory support patient data into a national database, INTERMACS. The power of INTERMACS data stems from the mandatory data submission on all durable mechanical circulatory devices, a formal process for adverse event adjudication, dedicated innovative electronic data submission, data element design to create a template for comparison with medical therapy, rigorous data monitoring, hospital auditing through the United Network of Organ Sharing, and a formal process for data access and publications. Since the inception of INTERMACS, an ongoing evolution of both strategies for device application and the types of available devices has continued to refine the landscape of mechanical circulatory support. Throughout this experience, the only device approved in the United States for permanent “destination” therapy was the HeartMate XVE2, a pulsatile ventricular assist device which is now known to frequently develop bearing wear and require device replacement within 2 years of implantation. Yet, in many countries outside the United States, newer axial flow and centrifugal flow rotary pumps provide chronic circulatory support. INTERMACS only collects data on devices which are FDA-approved for clinical use, and no adult rotary pump was approved in the United States for the first several years of the INTERMACS experience. The spectrum of devices entered into INTERMACS must also be viewed in the context of multiple concurrent U.S. clinical trials of continuous flow pumps implanted as bridge-to-transplant therapy as well as permanent support. Thus, for the first 2 years, despite the rigorous requirements for data completeness and accuracy, INTERMACS suffered from its inability to collect data on newer, more promising rotary pumps which were not yet FDA approved. The INTERMACS playing field changed dramatically in April of 2008, when the HeartMate II axial flow pump received FDA approval for clinical use as bridge-to-transplant therapy in the United States. A portion of this report will examine the changing practice patterns in the application of device type (continuous flow vs. pulsatile) and device strategies over the past three years. In fact, the genesis of INTERMACS, partly by chance and partly by design, uniquely positioned this database to observe, record, and analyze this historical transition (at least for the immediate future) from larger, powerful pulsatile pumps to the world of continuous flow technology, with the unproven promise of greater durability while retaining long-term patient functionality. This report begins the process of long-term evaluation of continuous flow technology against the background of a large registry of detailed patient and device data based on pulsatile pump technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
INTERMACS Profiles of Advanced Heart Failure: The Current Picture
Stevenson, L. W., Pagani, F. D., Young, J. B., Jessup, M., Miller, L., Kormos, R. L., Naftel, D. C., Ulisney, K., Desvigne-Nickens, P., & Kirklin, J. K. (2009) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2009.02.015 · Cited by 793
Self-citationThe REMATCH trial: rationale, design, and end points
Rose, E. A., Moskowitz, A. J., Packer, M., Sollano, J. A., Williams, D. L., Tierney, A. R., Heitjan, D. F., Meier, P., Ascheim, D. D., Levitan, R. G., et al. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00042-9 · Cited by 367
Self-citationINTERMACS Database for Durable Devices for Circulatory Support: First Annual Report
Kirklin, J. K., Naftel, D. C., Stevenson, L. W., Kormos, R. L., Pagani, F. D., Miller, M. A., Ulisney, K., & Young, J. B. (2008) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2008.07.021 · Cited by 366
Self-citation
Cited by
Marino, B. S., Lipkin, P. H., Newburger, J. W., Peacock, G., Gerdes, M., Gaynor, J. W., Mussatto, K. A., Uzark, K., Goldberg, C. S., Johnson, W. H., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318265ee8a · Cited by 1,608
Feldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Self-citationClinical management of continuous-flow left ventricular assist devices in advanced heart failure
Slaughter, M. S., Pagani, F. D., Rogers, J. G., Miller, L. W., Sun, B., Russell, S. D., Starling, R. C., Chen, L., Boyle, A. J., Chillcott, S., et al. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.01.011 · Cited by 874
Self-citation2010 Focused Update of ESC Guidelines on device therapy in heart failure
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., et al. (2010) · EP Europace · doi:10.1093/europace/euq392 · Cited by 593
Czech Society of Cardiology Guidelines for the Diagnosis and Treatment of Chronic Heart Failure 2011
Špinar, J., Vítovec, J., Hradec, J., Málek, I., Meluzín, J., Špinarová, L., Hošková, L., Hegarová, M., Ludka, O., & Táborský, M. (2012) · Cor et Vasa · doi:10.1016/j.crvasa.2012.03.002 · Cited by 10
Metadata
- Authors
- Kirklin, J. K., Naftel, D. C., Kormos, R. L., Stevenson, L. W., Pagani, F. D., Miller, M. A., Ulisney, K. L., Baldwin, J. T., & Young, J. B.
- Venue
- The Journal of Heart and Lung Transplantation
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 29
- Issue
- 1
- Pages
- 1-10
- ISSN
- 1053-2498 (ISSN-L)
- OpenAlex
- W2065220165
- Cited by
- 386
- References
- 3
- FWCI
- 32.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Second INTERMACS annual report: More than 1,000 primary left ventricular assist device implants. https://app.cochat.ai/papers/10.1016/j.healun.2009.10.009
- The paper
- Kirklin, J. K., Naftel, D. C., Kormos, R. L., Stevenson, L. W., Pagani, F. D., Miller, M. A., Ulisney, K. L., Baldwin, J. T., & Young, J. B. (2010). Second INTERMACS annual report: More than 1,000 primary left ventricular assist device implants. The Journal of Heart and Lung Transplantation. https://doi.org/10.1016/j.healun.2009.10.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.