Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 460

The DOI matches its Crossref record.

An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial

Open access
Najjar, Samer S., Slaughter, Mark S., Pagani, Francis D., Starling, Randall C., McGee, Edwin C., Eckman, Peter, Tatooles, Antone J., Moazami, Nader, Kormos, Robert L., Hathaway, David R., Najarian, Kevin B., Bhat, Geetha, Aaronson, Keith D., Boyce, Steven W.·2014·The Journal of Heart and Lung Transplantation

Abstract

BACKGROUND: The HeartWare left ventricular assist device (HVAD, HeartWare Inc, Framingham, MA) is the first implantable centrifugal continuous-flow pump approved for use as a bridge to transplantation. An infrequent but serious adverse event of LVAD support is thrombus ingestion or formation in the pump. In this study, we analyze the incidence of pump thrombus, evaluate the comparative effectiveness of various treatment strategies, and examine factors pre-disposing to the development of pump thrombus. METHODS: The analysis included 382 patients who underwent implantation of the HVAD as part of the HeartWare Bridge to Transplant (BTT) and subsequent Continued Access Protocol (CAP) trial. Descriptive statistics and group comparisons were generated to analyze baseline characteristics, incidence of pump thrombus, and treatment outcomes. A multivariate analysis was performed to assess significant risk factors for developing pump thrombus. RESULTS: There were 34 pump thrombus events observed in 31 patients (8.1% of the cohort) for a rate of 0.08 events per patient-year. The incidence of pump thrombus did not differ between BTT and CAP. Medical management of pump thrombus was attempted in 30 cases, and was successful in 15 (50%). A total of 16 patients underwent pump exchange, and 2 underwent urgent transplantation. Five patients with a pump thrombus died after medical therapy failed, 4 of whom also underwent a pump exchange. Survival at 1 year in patients with and without a pump thrombus was 69.4% and 85.5%, respectively (p = 0.21). A multivariable analysis revealed that significant risk factors for pump thrombus included a mean arterial pressure > 90 mm Hg, aspirin dose ≤ 81 mg, international normalized ratio ≤ 2, and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile level of ≥ 3 at implant. CONCLUSIONS: Pump thrombus is a clinically important adverse event in patients receiving an HVAD, occurring at a rate of 0.08 events per patient-year. Significant risk factors for pump thrombosis include elevated blood pressure and sub-optimal anti-coagulation and anti-platelet therapies. This suggests that pump thrombus event rates could be reduced through careful adherence to patient management guidelines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.healun.2013.12.001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 460

Metadata

Authors
Najjar, S. S., Slaughter, M. S., Pagani, F. D., Starling, R. C., McGee, E. C., Eckman, P., Tatooles, A. J., Moazami, N., Kormos, R. L., Hathaway, D. R., Najarian, K. B., Bhat, G., Aaronson, K. D., & Boyce, S. W.
Venue
The Journal of Heart and Lung Transplantation
Publisher
Elsevier BV
Published
2014-01
Volume
33
Issue
1
Pages
23-34
ISSN
1053-2498 (ISSN-L)
OpenAlex
W2103149583
Cited by
460
References
0
FWCI
22.14
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. https://app.cochat.ai/papers/10.1016/j.healun.2013.12.001
The paper
Najjar, S. S., Slaughter, M. S., Pagani, F. D., Starling, R. C., McGee, E. C., Eckman, P., Tatooles, A. J., Moazami, N., Kormos, R. L., Hathaway, D. R., Najarian, K. B., Bhat, G., Aaronson, K. D., & Boyce, S. W. (2014). An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. The Journal of Heart and Lung Transplantation. https://doi.org/10.1016/j.healun.2013.12.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.