An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The HeartWare left ventricular assist device (HVAD, HeartWare Inc, Framingham, MA) is the first implantable centrifugal continuous-flow pump approved for use as a bridge to transplantation. An infrequent but serious adverse event of LVAD support is thrombus ingestion or formation in the pump. In this study, we analyze the incidence of pump thrombus, evaluate the comparative effectiveness of various treatment strategies, and examine factors pre-disposing to the development of pump thrombus. METHODS: The analysis included 382 patients who underwent implantation of the HVAD as part of the HeartWare Bridge to Transplant (BTT) and subsequent Continued Access Protocol (CAP) trial. Descriptive statistics and group comparisons were generated to analyze baseline characteristics, incidence of pump thrombus, and treatment outcomes. A multivariate analysis was performed to assess significant risk factors for developing pump thrombus. RESULTS: There were 34 pump thrombus events observed in 31 patients (8.1% of the cohort) for a rate of 0.08 events per patient-year. The incidence of pump thrombus did not differ between BTT and CAP. Medical management of pump thrombus was attempted in 30 cases, and was successful in 15 (50%). A total of 16 patients underwent pump exchange, and 2 underwent urgent transplantation. Five patients with a pump thrombus died after medical therapy failed, 4 of whom also underwent a pump exchange. Survival at 1 year in patients with and without a pump thrombus was 69.4% and 85.5%, respectively (p = 0.21). A multivariable analysis revealed that significant risk factors for pump thrombus included a mean arterial pressure > 90 mm Hg, aspirin dose ≤ 81 mg, international normalized ratio ≤ 2, and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile level of ≥ 3 at implant. CONCLUSIONS: Pump thrombus is a clinically important adverse event in patients receiving an HVAD, occurring at a rate of 0.08 events per patient-year. Significant risk factors for pump thrombosis include elevated blood pressure and sub-optimal anti-coagulation and anti-platelet therapies. This suggests that pump thrombus event rates could be reduced through careful adherence to patient management guidelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Self-citationA Method to Determine the Optimal Intensity of Oral Anticoagulant Therapy
Rosendaal, F. R., Cannegieter, S. C., van der Meer, F. J. M., & Briët, E. (1993) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1651587 · Cited by 2,065
Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Self-citationFeldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Self-citationExtended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
Pagani, F. D., Miller, L. W., Russell, S. D., Aaronson, K. D., John, R., Boyle, A. J., Conte, J. V., Bogaev, R. C., MacGillivray, T. E., Naka, Y., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.055 · Cited by 869
Self-citationUnexpected Abrupt Increase in Left Ventricular Assist Device Thrombosis
Starling, R. C., Moazami, N., Silvestry, S. C., Ewald, G., Rogers, J. G., Milano, C. A., Rame, J. E., Acker, M. A., Blackstone, E. H., Ehrlinger, J., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313385 · Cited by 786
Self-citationRogers, J. G., Aaronson, K. D., Boyle, A. J., Russell, S. D., Milano, C. A., Pagani, F. D., Edwards, B. S., Park, S., John, R., Conte, J. V., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.052 · Cited by 586
Self-citationKirklin, J. K., Naftel, D. C., Kormos, R. L., Pagani, F. D., Myers, S. L., Stevenson, L. W., Acker, M. A., Goldstein, D., Silvestry, S., Milano, C. A., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.11.001 · Cited by 416
Self-citationSlaughter, M. S., Pagani, F. D., McGee, E. C., Birks, E. J., Cotts, W. G., Gregoric, I., Howard Frazier, O., Icenogle, T., Najjar, S. S., Boyce, S. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.04.004 · Cited by 349
Self-citationPark, S. J., Milano, C. A., Tatooles, A. J., Rogers, J. G., Adamson, R. M., Steidley, D. E., Ewald, G. A., Sundareswaran, K. S., Farrar, D. J., Slaughter, M. S., et al. (2012) · Circulation: Heart Failure · doi:10.1161/circheartfailure.111.963991 · Cited by 341
Self-citation
Cited by
Unexpected Abrupt Increase in Left Ventricular Assist Device Thrombosis
Starling, R. C., Moazami, N., Silvestry, S. C., Ewald, G., Rogers, J. G., Milano, C. A., Rame, J. E., Acker, M. A., Blackstone, E. H., Ehrlinger, J., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313385 · Cited by 786
Self-citationIntrapericardial Left Ventricular Assist Device for Advanced Heart Failure
Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1602954 · Cited by 758
Self-citationA Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure
Mehra, M. R., Naka, Y., Uriel, N., Goldstein, D. J., Cleveland, J. C., Colombo, P. C., Walsh, M. N., Milano, C. A., Patel, C. B., Jorde, U. P., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1610426 · Cited by 751
Self-citationSudden cardiac arrest survivorship: a scientific statement from the American Heart Association
Sawyer, K. N., Camp-Rogers, T. R., Kotini-Shah, P., Del Rios, M., Gossip, M. R., Moitra, V. K., Haywood, K. L., Dougherty, C. M., Lubitz, S. A., Rabinstein, A. A., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000747 · Cited by 311
Left Ventricular Assist Device Therapy in Advanced Heart Failure: Patient Selection and Outcomes
Gustafsson, F., & Rogers, J. G. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.779 · Cited by 269
Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine
Han, J. J., Acker, M. A., & Atluri, P. (2018) · Circulation · doi:10.1161/circulationaha.118.035566 · Cited by 201
The HVAD Left Ventricular Assist Device
Teuteberg, J. J., Slaughter, M. S., Rogers, J. G., McGee, E. C., Pagani, F. D., Gordon, R., Rame, E., Acker, M., Kormos, R. L., Salerno, C., et al. (2015) · JACC: Heart Failure · doi:10.1016/j.jchf.2015.05.011 · Cited by 197
Self-citationThe vexing problem of thrombosis in long-term mechanical circulatory support
Mehra, M. R., Stewart, G. C., & Uber, P. A. (2014) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.12.002 · Cited by 185
Netuka, I., Ivák, P., Tučanová, Z., Gregor, S., Szárszoi, O., Sood, P., Crandall, D., Rimsans, J., Connors, J. M., & Mehra, M. R. (2018) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2018.03.002 · Cited by 168
Moayedi, Y., Duero Posada, J. G., Foroutan, F., Goldraich, L. A., Alba, A. C., MacIver, J., & Ross, H. J. (2018) · Clinical Transplantation · doi:10.1111/ctr.13158 · Cited by 22
Metadata
- Authors
- Najjar, S. S., Slaughter, M. S., Pagani, F. D., Starling, R. C., McGee, E. C., Eckman, P., Tatooles, A. J., Moazami, N., Kormos, R. L., Hathaway, D. R., Najarian, K. B., Bhat, G., Aaronson, K. D., & Boyce, S. W.
- Venue
- The Journal of Heart and Lung Transplantation
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 33
- Issue
- 1
- Pages
- 23-34
- ISSN
- 1053-2498 (ISSN-L)
- OpenAlex
- W2103149583
- Cited by
- 460
- References
- 12
- FWCI
- 22.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.