Tinnitus suppression by low-rate electric stimulation and its electrophysiological mechanisms
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Tinnitus is a phantom sensation of sound in the absence of external stimulation. However, external stimulation, particularly electric stimulation via a cochlear implant, has been shown to suppress tinnitus. Different from traditional methods of delivering speech sounds or high-rate (>2,000 Hz) stimulation, the present study found a unique unilaterally-deafened cochlear implant subject whose tinnitus was completely suppressed by a low-rate (<100 Hz) stimulus, delivered at a level softer than tinnitus to the apical part of the cochlea. Taking advantage of this novel finding, the present study compared both event-related and spontaneous cortical activities in the same subject between the tinnitus-present and tinnitus-suppressed states. Compared with the results obtained in the tinnitus-presentstate, the low-rate stimulus reduced cortical N100 potentials while increasing the spontaneous alpha power in the auditory cortex. These results are consistent with previous neurophysiological studies employing subjects with and without tinnitus and shed light on both tinnitus mechanism and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric statistical testing of EEG- and MEG-data
Maris, E., & Oostenveld, R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.024 · Cited by 8,496 · cited 1×
“Differences in the spontaneous oscillatory power between tinnitus-present and tinnitus-suppressed states were assessed across scalp topographies using a nonparametric t-test cluster analysis (Maris and Oostenveld, 2007).”
Method
Cited by
Kraus, K. S., & Canlon, B. (2012) · Hearing Research · doi:10.1016/j.heares.2012.02.009 · Cited by 267
Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
“at SciVerse ScienceDirect Contents lists available Hearing Research journal homepage: www.elsevier .com/locate/heares Research paper Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation Ziyan Zhu a,b,c,*, Qing Tang c, Fan-Gang Zeng c,**, Tian Guan b, Datian Ye a,b,* aDepartment of Biom…”
BackgroundSelf-citationThe state of the art of sound therapy for subjective tinnitus in adults
Wang, H., Tang, D., Wu, Y., Zhou, L., & Sun, S. (2020) · Therapeutic Advances in Chronic Disease · doi:10.1177/2040622320956426 · Cited by 52
Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis
Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M. (2015) · Audiology and Neurotology · doi:10.1159/000380750 · Cited by 46
“Acute experimental studies have shown substantial variability in the efficacy of different stimulation paradigms [Dauman et al., 1993; Rubinstein et al., 2003; Tyler et al., 2008; Di Nardo et al., 2009; Zeng et al., 2011; Chang and Zeng, 2012; Arts et al., 2015].”
Background
Metadata
- Authors
- Zeng, F.-G., Tang, Q., Dimitrijevic, A., Starr, A., Larky, J., & Blevins, N. H.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 277
- Issue
- 1-2
- Pages
- 61-66
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W1988398545
- Cited by
- 77
- References
- 1
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.