A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Hyperacusis is defined as an increased sensitivity to sounds, i.e. sounds presented at moderate levels can produce discomfort or even pain. Existing diagnostic methods, like the Hyperacusis Questionnaire (HQ) and Loudness Discomfort Levels (LDLs), have been challenged because of their variability and lack of agreement on appropriate cut-off values. We propose a novel approach by using psychoacoustic ratings of natural sounds as an assessment tool for hyperacusis. Subjects (n = 81) were presented with natural and artificial (tone pips, noises) sounds (n = 69) in a controlled environment at four sound levels (60, 70, 80 and 90 dB SPL). The task was to rate them on a pleasant to unpleasant visual analog scale. The inherent challenge of this study was to create a new diagnostic tool when no gold standard of hyperacusis diagnosis exists. We labeled our subjects as hyperacusic (n = 26) when they were diagnosed as such by at least two of three methods (HQ, LDLs and self-report). There was a significant difference between controls (n = 23) and hyperacusics in the median global rating of pleasant sounds. Median global ratings of unpleasant sounds and artificial sounds did not differ significantly. Then we selected the subset of sounds that could best discriminate the controls from the hyperacusics, the Core Discriminant Sounds (CDS), and we used them to develop a new metric: The CDS score. A normalized global score and a score for each sound level can be computed with respect to a control population without hyperacusis. A receiver operating characteristic analysis showed that the accuracy of our method in distinguishing subjects with and without complaints of hyperacusis (86%, 95% Confidence Interval (CI): 76-93%) is comparable to that of existing methods such as the LDL (77%, CI: 67-86%) and the HQ (80%, CI: 69-88%). We believe that the CDS score is more relevant to subject's complaints than LDLs and that it could be applied in a clinical environment in a fast and effective way, while minimizing discomfort and biases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect size estimates: Current use, calculations, and interpretation.
Fritz, C. O., Morris, P. E., & Richler, J. J. (2012) · Journal of Experimental Psychology: General · doi:10.1037/a0024338 · Cited by 5,199
Psychometric Normalization of a Hyperacusis Questionnaire
Khalfa, S., Dubal, S., Veuillet, E., Perez-Diaz, F., Jouvent, R., & Collet, L. (2002) · ORL · doi:10.1159/000067570 · Cited by 488
Misophonia: Physiological investigations and case descriptions
Edelstein, M., Brang, D., Rouw, R., & Ramachandran, V. S. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00296 · Cited by 330
A review of hyperacusis and future directions: Part I. Definitions and manifestations
Tyler, R. S., Pienkowski, M., Roncancio, E. R., Jun, H. J., Brozoski, T., Dauman, N., Coelho, C. B., Andersson, G., Keiner, A. J., Cacace, A. T., et al. (2014) · American Journal of Audiology · doi:10.1044/2014_aja-14-0010 · Cited by 329
Hypersensitivity to sound: Questionnaire data, audiometry and classification
Anari, M., Axelsson, A., Eliasson, A., & Magnusson, L. (1999) · Scandinavian Audiology · doi:10.1080/010503999424653 · Cited by 271
Assessment and amelioration of hyperacusis in tinnitus patients
Dauman, R., & Bouscau-Faure, F. (2005) · Acta Oto-Laryngologica · doi:10.1080/00016480510027565 · Cited by 179
Characteristics of hyperacusis in the general population
Paulin, J., Andersson, L., & Nordin, S. (2016) · Noise and Health · doi:10.4103/1463-1741.189244 · Cited by 139
Enriched acoustic environment rescales auditory sensitivity
Noreña, A. J., & Chery-Croze, S. (2007) · NeuroReport · doi:10.1097/wnr.0b013e3282202c35 · Cited by 130
Self-citationSherlock, L. P., & Formby, C. (2005) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.16.2.4 · Cited by 127
Psychiatric comorbidity and personality traits in patients with hyperacusis
Jüris, L., Andersson, G., Larsen, H. C., & Ekselius, L. (2013) · International Journal of Audiology · doi:10.3109/14992027.2012.743043 · Cited by 114
Cited by
A psychoacoustic test for misophonia assessment
Enzler, F., Loriot, C., Fournier, P., & Noreña, A. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-90355-8 · Cited by 54
Self-citationFournier, P., Paleressompoulle, D., Esteve Fraysse, M.-J., Paolino, F., Devèze, A., Venail, F., & Noreña, A. (2022) · Hearing Research · doi:10.1016/j.heares.2022.108519 · Cited by 20
Self-citationClinical and investigational tools for monitoring noise-induced hyperacusis
Jahn, K. N. (2022) · The Journal of the Acoustical Society of America · doi:10.1121/10.0012684 · Cited by 20
Evaluation and Management of Misophonia Using a Hybrid Telecare Approach: A Case Report
Zitelli, L. (2021) · Seminars in Hearing · doi:10.1055/s-0041-1731693 · Cited by 4
Metadata
- Authors
- Enzler, F., Fournier, P., & Noreña, A. J.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 400
- Pages
- 108124
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W3109228822
- Cited by
- 51
- References
- 15
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds. https://app.cochat.ai/papers/10.1016/j.heares.2020.108124
- The paper
- Enzler, F., Fournier, P., & Noreña, A. J. (2021). A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds. Hearing Research. https://doi.org/10.1016/j.heares.2020.108124
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.