CoChat

A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds

Open access
Enzler, Falco, Fournier, Philippe, Noreña, Arnaud J. · 2021 · Hearing Research
Cited by 51

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Hyperacusis is defined as an increased sensitivity to sounds, i.e. sounds presented at moderate levels can produce discomfort or even pain. Existing diagnostic methods, like the Hyperacusis Questionnaire (HQ) and Loudness Discomfort Levels (LDLs), have been challenged because of their variability and lack of agreement on appropriate cut-off values. We propose a novel approach by using psychoacoustic ratings of natural sounds as an assessment tool for hyperacusis. Subjects (n = 81) were presented with natural and artificial (tone pips, noises) sounds (n = 69) in a controlled environment at four sound levels (60, 70, 80 and 90 dB SPL). The task was to rate them on a pleasant to unpleasant visual analog scale. The inherent challenge of this study was to create a new diagnostic tool when no gold standard of hyperacusis diagnosis exists. We labeled our subjects as hyperacusic (n = 26) when they were diagnosed as such by at least two of three methods (HQ, LDLs and self-report). There was a significant difference between controls (n = 23) and hyperacusics in the median global rating of pleasant sounds. Median global ratings of unpleasant sounds and artificial sounds did not differ significantly. Then we selected the subset of sounds that could best discriminate the controls from the hyperacusics, the Core Discriminant Sounds (CDS), and we used them to develop a new metric: The CDS score. A normalized global score and a score for each sound level can be computed with respect to a control population without hyperacusis. A receiver operating characteristic analysis showed that the accuracy of our method in distinguishing subjects with and without complaints of hyperacusis (86%, 95% Confidence Interval (CI): 76-93%) is comparable to that of existing methods such as the LDL (77%, CI: 67-86%) and the HQ (80%, CI: 69-88%). We believe that the CDS score is more relevant to subject's complaints than LDLs and that it could be applied in a clinical environment in a fast and effective way, while minimizing discomfort and biases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.heares.2020.108124

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 51

Metadata

Authors
Enzler, F., Fournier, P., & Noreña, A. J.
Venue
Hearing Research
Publisher
Elsevier BV
Published
2021-02
Volume
400
Pages
108124
ISSN
0378-5955 (ISSN-L)
OpenAlex
W3109228822
Cited by
51
References
15
FWCI
1.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds. https://app.cochat.ai/papers/10.1016/j.heares.2020.108124
The paper
Enzler, F., Fournier, P., & Noreña, A. J. (2021). A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds. Hearing Research. https://doi.org/10.1016/j.heares.2020.108124

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.