CoChat

A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds

Open access
Enzler, Falco, Fournier, Philippe, Noreña, Arnaud J. · 2021 · Hearing Research
Cited by 51

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Hyperacusis is defined as an increased sensitivity to sounds, i.e. sounds presented at moderate levels can produce discomfort or even pain. Existing diagnostic methods, like the Hyperacusis Questionnaire (HQ) and Loudness Discomfort Levels (LDLs), have been challenged because of their variability and lack of agreement on appropriate cut-off values. We propose a novel approach by using psychoacoustic ratings of natural sounds as an assessment tool for hyperacusis. Subjects (n = 81) were presented with natural and artificial (tone pips, noises) sounds (n = 69) in a controlled environment at four sound levels (60, 70, 80 and 90 dB SPL). The task was to rate them on a pleasant to unpleasant visual analog scale. The inherent challenge of this study was to create a new diagnostic tool when no gold standard of hyperacusis diagnosis exists. We labeled our subjects as hyperacusic (n = 26) when they were diagnosed as such by at least two of three methods (HQ, LDLs and self-report). There was a significant difference between controls (n = 23) and hyperacusics in the median global rating of pleasant sounds. Median global ratings of unpleasant sounds and artificial sounds did not differ significantly. Then we selected the subset of sounds that could best discriminate the controls from the hyperacusics, the Core Discriminant Sounds (CDS), and we used them to develop a new metric: The CDS score. A normalized global score and a score for each sound level can be computed with respect to a control population without hyperacusis. A receiver operating characteristic analysis showed that the accuracy of our method in distinguishing subjects with and without complaints of hyperacusis (86%, 95% Confidence Interval (CI): 76-93%) is comparable to that of existing methods such as the LDL (77%, CI: 67-86%) and the HQ (80%, CI: 69-88%). We believe that the CDS score is more relevant to subject's complaints than LDLs and that it could be applied in a clinical environment in a fast and effective way, while minimizing discomfort and biases.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.heares.2020.108124

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 22

  1. Aazh, 2017, Factors related to uncomfortable loudness levels for patients seen in a tinnitus and hyperacusis clinic, Int. J. Audiol., 56, 793, 10.1080/14992027.2017.1335888 · DOI · Paper page
  2. Bläsing, 2010, Hypersensitivity to sound in tinnitus patients: an analysis of a construct based on questionnaire and audiological data, Int. J. Audiol., 49, 518, 10.3109/14992021003724996 · DOI · Paper page
  3. Bowsher, 1962, On scaling the unpleasantness of sounds, Br. J. Appl. Phys., 13, 179, 10.1088/0508-3443/13/4/315 · doi:10.1088/0508-3443/13/4/315
  4. Delacour, 2005, La Courbe ROC (receiver operating characteristic) : principes et principales applications en biologie clinique, Ann Biol Clin, 63, 11
  5. Fackrell, 2019, Top ten hyperacusis research priorities in the UK, The Lancet, 393, 404, 10.1016/S0140-6736(18)32616-3 · DOI
  6. Gloaguen, 2017, Creation of a corpus of realistic urban sound scenes with controlled acoustic properties, J. Acoust. Soc. Am., 141, 4044, 10.1121/1.4989346 · doi:10.1121/1.4989346
  7. Goldstein, 1996, Tinnitus – hyperacusis and the loudness discomfort level test – a preliminary report, Int. Tinnitus J., 2, 83
  8. Greenberg, 2018, Psychometric properties and factor structure of a new scale to measure hyperacusis: introducing the inventory of hyperacusis symptoms, Ear Hear., 39, 1025, 10.1097/AUD.0000000000000583 · DOI · Paper page
  9. Hébert, 2013, The auditory sensitivity is increased in tinnitus ears, J. Neurosci., 33, 2356, 10.1523/JNEUROSCI.3461-12.2013 · DOI · Paper page
  10. Kayan, 1984, Neuro-otological manifestations of migraine, Brain J. Neurol., 107, 1123, 10.1093/brain/107.4.1123 · DOI · Paper page
  11. Khalfa, 2004, Increased perception of loudness in autism, Hear. Res., 198, 87, 10.1016/j.heares.2004.07.006 · DOI · Paper page
  12. Kleiner, 2007, What's new in Psychtoolbox-3, Perception, 36, 1
  13. Kochkin, 2000, MarkeTrak V: “why my hearing aids are in the drawer”: the consumers’ perspective, Hear. J., 53, 39, 10.1097/00025572-200002000-00004 · doi:10.1097/00025572-200002000-00004
  14. Kumar, 2008, Mapping unpleasantness of sounds to their auditory representation, J. Acoust. Soc. Am., 124, 3810, 10.1121/1.3006380 · DOI · Paper page
  15. Kumar, 2012, Features versus feelings: dissociable representations of the acoustic features and valence of aversive sounds, J. Neurosci., 32, 14184, 10.1523/JNEUROSCI.1759-12.2012 · DOI · Paper page
  16. Levy-Leboyer, 1991, Neighbourhood noise annoyance, J. Environ. Psychol., 11, 75, 10.1016/S0272-4944(05)80006-4 · DOI
  17. Marks, 2011, Measurement of loudness, part I: methods, problems, and pitfalls, 17, 10.1007/978-1-4419-6712-1_2 · DOI
  18. Meeus, 2010, Correlation between hyperacusis measurements in daily ENT practice, Int. J. Audiol., 49, 7, 10.3109/14992020903160868 · DOI · Paper page
  19. Newcombe, R.G., 1998. Two-Sided Confidence Intervals for the Single Proportion: Comparison of Seven Methods 16. https://doi.org/ 10.1002/(sici)1097-0258(19980430)17:8 <857::aid-sim777>3.0.co;2-e · DOI · Paper page
  20. Sheldrake, 2015, Audiometric characteristics of hyperacusis patients, Front. Neurol., 6, 105, 10.3389/fneur.2015.00105 · DOI · Paper page
  21. Shimai, 1992, Emotion and identification of environmental sounds and electroencephalographic activity [abstract], Fukushima J. Med. Sci., 38, 43
  22. Stephens, 1977, The value of some suprathreshold auditory measures, Scand. Audiol., 6, 213, 10.3109/01050397709043123 · DOI

Cited by

See all 51

Metadata

Authors
Enzler, F., Fournier, P., & Noreña, A. J.
Venue
Hearing Research
Publisher
Elsevier BV
Published
2021-02
Volume
400
Pages
108124
ISSN
0378-5955 (ISSN-L)
OpenAlex
W3109228822
Cited by
51
References
17
FWCI
1.81
Type
journal article
Language
en
Open access
bronze
Licence
Funders
  • Horizon 2020
  • European Research Council (764604)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.